Charge Controllers
A solar charge controller sits between your solar panels and your battery bank. It feeds the batteries the right voltage and current, stops charging when they are full, and keeps them from draining back through the panels at night. Standalone charge controllers are not listed online right now. Every inverter listed in our off-grid inverters and hybrid inverters collections has a built-in MPPT solar charger, so many battery systems do not need a separate controller.
Read more about Charge Controllers
- Off-grid cabin, shop or home on a 48 V battery: a RUiXU SUNON all-in-one combines an inverter, an MPPT solar charger and a grid or generator battery charger in one indoor unit.
- Grid-tied home that also wants backup: a hybrid inverter charges batteries from solar through its own MPPT inputs.
- Batteries: lithium (LFP) and lead-acid batteries in solar batteries.
- Small 12 V or 24 V system: 12 V and 24 V solar panels are listed. The controller itself is by written quote request.
Nothing in this category is available to order online right now
Use the guide on this page, browse related equipment, or send us a written quote request.
Need something from this category?
Send a written quote request. No payment is taken.
Request a quoteNot sure what to use instead?
Get one hour of personalized help with equipment selection, system questions, commissioning, or troubleshooting. Purchase your session, then use the scheduling link provided after checkout to choose an appointment.
What a charge controller does
Solar panels put out more voltage than a battery needs. A 12 V panel, for example, often runs near 18 V while it is working. Without a controller, the panels keep pushing current into a full battery, which can damage it and create a safety risk. A charge controller prevents that. It charges in stages: bulk (as much current as possible until the battery is roughly 80% full), absorption (current tapers as the battery nears full) and float (a small charge to keep it topped off). It also blocks reverse current, so the battery does not slowly discharge through the panels after dark. Some controllers add a load output with low-voltage disconnect, a display, or a data port for monitoring. Read more in how a solar charge controller works.
Grid-tied systems without batteries do not use a charge controller. If there is a battery, something has to control its charging. That can be a standalone controller or an inverter with a built-in MPPT charger.
MPPT vs PWM
| Point | PWM controller | MPPT controller |
|---|---|---|
| How it works | Sends panel power to the battery in rapid pulses and adjusts the rate to hold the battery at the right voltage. | Finds the panel voltage that makes the most power, then converts the extra voltage into extra charging current. |
| Array voltage | Panel nominal voltage must match the battery: a 12 V array for a 12 V battery, 24 V for 24 V, 48 V for 48 V. | The array can run at a much higher voltage than the battery, inside the controller's input window. |
| Wiring | The array runs at battery-level voltage, so long wire runs need heavier wire. | Panels can be wired in series at higher voltage, which means smaller wire, less voltage drop and fewer breakers. |
| Where it fits | Small, simple systems with short wire runs. | Larger arrays, long wire runs, cold sites and systems that may grow. |
| Trade-offs | Lower cost and simple design, but less room to grow. | Costs more and is physically larger. Every string in an array should use matching panels. |
Compare them in more detail in comparing PWM and MPPT charge controllers and should I use an MPPT or PWM charge controller?
How to size a charge controller
- Battery voltage: pick the controller for your battery bank voltage (12 V, 24 V or 48 V), and set its charge profile to the battery maker's settings.
- Array voltage at your coldest temperature: panel voltage rises as the panels get colder. Multiply each panel's open-circuit voltage (Voc) by the number in series, then add a cold-weather factor. In our sizing guide's example, three 38 V Voc panels in series on a 30°F morning give 38 × 3 × 1.12 = about 128 V. That is fine for a 150 V controller but too high for a 100 V one, and going over the limit can permanently damage the controller.
- Charging current: divide array watts by battery voltage. A 1,000 W array charging a 24 V bank works out to about 42 A, so the controller's output rating has to be in that range. The MPPT sizing guide explains when slightly over-paneling a controller makes sense.
- Panel current and string count: stay within the controller's input current limit and the panel maker's limits on panels in parallel.
- PWM systems: match the array to the battery. For example, the SLD Tech ST-150Q-12Y 150 W 12 V panel lists 18.53 V Vmp and 21.37 V Voc, a typical 12 V panel for a 12 V bank. The SLD Tech ST-150R-24 150 W 24 V panel is built for a 24 V bank. See sizing PWM solar charge controllers.
- Bigger arrays: two or more controllers can charge one battery bank, each with its own output breaker to the battery. See wiring charge controllers in parallel.
For the full temperature math, read sizing MPPT charge controllers and temperature.
Inverters with a built-in MPPT charger
These inverters charge the battery from solar through their own MPPT inputs, so the same sizing rules apply to them. Keep every string inside the MPPT range and below the maximum PV voltage at your coldest temperature. Figures below come from each product page.
| Inverter | Battery | Solar input | Max PV voltage | Max charge current |
|---|---|---|---|---|
| RUiXU SUNON3.6 (off-grid, 120 V) | 48 V (40–60 V); lithium-ion, lead-acid or user-defined | 1 MPPT, 90–260 VDC, 4,500 W | 300 VDC open-circuit | 80 A solar |
| RUiXU SUNON7.2 (off-grid, 120/240 V) | 48 V (40–60 V); lithium-ion, lead-acid or user-defined | 2 MPPTs, 90–450 VDC, 4,500 W each | 500 VDC open-circuit | 150 A solar |
| RUiXU SUNON12 (off-grid, 120/240 V) | 48 V (40–60 V); lithium-ion, lead-acid or user-defined | 2 MPPTs, 90–450 VDC, 12,000 W each | 500 VDC open-circuit | 250 A solar |
| Sol-Ark 12K-2P (hybrid) | 48 V (43–63 V); battery temperature sensor included | 2 MPPTs, 150–500 V, 12,000 W usable | 500 V | 185 A battery charge/discharge |
| Sol-Ark Limitless 15K-2P (hybrid) | 48 V (43–59 V); lead-acid or lithium | 3 MPPTs, 150–425 V, 19,500 W usable | 500 V | 275 A battery charge |
| Sol-Ark 18K-2P-N (hybrid) | 48 V (43–59 V); lead-acid or lithium | 3 MPPTs, 150–425 V, 28,800 W usable | 500 V | 350 A battery charge |
| Solis S6 16kW (hybrid) | 40–60 V; Li-ion or lead-acid | 3 MPPTs, 100–450 V (full load 186–450 V), 25.6 kW recommended maximum | 550 V | 290 A battery charge/discharge |
| GoodWe ES-US 11.4kW (hybrid) | High-voltage Li-ion, 300 V nominal (80–495 V), not a 48 V battery | 4 MPPTs, 50–550 V, 17,100 W | 600 V | 50 A battery charge/discharge |
Hybrid and off-grid inverters differ in more than charging. Read what an inverter/charger is, and compare the full lineups in off-grid inverters and hybrid inverters.
What else a charge controller system needs
- Batteries: a bank at the controller's voltage. For example, the Crown 12CRV110 12 V AGM battery or the Briggs & Stratton PHI 3.8-M LFP battery in 24 V or 48 V. Briggs & Stratton says charger settings must be changed to the PHI battery's settings. See how to size a deep cycle battery bank.
- Breakers or fuses and disconnects: DC overcurrent protection and a way to switch off the circuit, both between the array and the controller and between the controller and the battery. If the array's cold-weather voltage is above 150 VDC, the breakers and enclosure between the panels and the controller must be rated for that voltage. See high-voltage MPPT considerations. DC breakers and fuses are by written quote request; disconnects and breakers covers AC disconnects and breakers.
- Cables: 10 AWG MC4 PV cable from the array, and battery cables such as the 4/0 AWG red and black 96" cables with 3/8" lugs. Size the wire and its breaker together; see recommended inverter cable, breaker and fuse sizing and cable and wiring.
- Battery temperature sensor: lets the charger adjust its charging to the battery's temperature, which helps protect the battery. Lithium batteries include their own battery management system (BMS).
- Monitoring: a battery monitor shows state of charge, voltage and temperature. Most of the inverters above list Wi-Fi or app monitoring, and SimpliPHI battery owners can add the EnergyTrak gateway. Read how to monitor solar batteries.
If charging stops or looks low, start with charge controller troubleshooting.
FAQ
What is the difference between MPPT and PWM charge controllers?
A PWM controller connects the panels almost directly to the battery and switches them on and off to hold the right voltage, so the array's nominal voltage has to match the battery. An MPPT controller tracks the panels' maximum power point and converts higher array voltage into more charging current, so you can wire panels in series and use smaller wire. PWM suits small, simple systems. MPPT suits larger arrays, long wire runs and systems that may grow.
When does a hybrid inverter with built-in MPPT replace a standalone charge controller?
When the solar array connects to the inverter's own PV inputs, the inverter's MPPT charger controls battery charging, so a separate controller is not needed for that array. A separate controller can still make sense for a second array wired straight to the battery, often called DC coupling. Check that each string fits the inverter's MPPT voltage range and current limits.
Are standalone charge controllers listed online?
Not right now. Send a written quote request with your battery voltage, panel model, number of panels and how you plan to wire them, and we will reply by email with the options we can supply.
What size charge controller do I need?
Start with your battery voltage. Then check that the array's cold-weather open-circuit voltage stays under the controller's maximum input voltage, and that array watts divided by battery voltage fits the controller's output current rating. A 1,000 W array on a 24 V bank works out to about 42 A.
Can I connect solar panels straight to a battery?
No. A 12 V panel can put out 16 to 20 V, and most 12 V batteries are full at about 14 to 14.5 V. Without a controller, the panels keep charging past full, which can damage the battery.
Do lithium batteries need a different charge controller?
They need the right settings. Use a controller or inverter that offers a charge profile matching the battery maker's voltage and current settings, and follow the battery manual. Some lithium batteries also share data with the inverter over a communication cable. Check the battery and inverter manuals before you pair them.
Can I use more than one charge controller on the same battery bank?
Yes. Split the array between controllers, and run each controller's output through its own breaker to the battery bank. Each controller charges on its own, and their currents add up.