Enclosures, Electrical and Safety
- EatonSKUDG224NRK$1,350.21Available to order Shipping calculated at checkout
- EatonSKUDG224URK
Eaton Non-Fusible AC Disconnect, 200A, 240V – DG224URK
$1,315.46Available to order Shipping calculated at checkout - EatonSKUDG223URB
Eaton Non-Fusible AC Disconnect, 100A, 240V – DG223URB
$396.04Available to order Shipping calculated at checkout - EatonSKUDG222NRB
Eaton Fusible AC Disconnect, 60A, 240V – DG222NRB
$292.94Available to order Shipping calculated at checkout - FCD LabelsSKU20-027
FCD Labels 2020 Battery Add-On Sticker Pack, 18 pcs – 20-027
$16.68Available to order Shipping calculated at checkout - Enphase EnergySKUX-IQ-AM1-240-6C-3BRK
Enphase IQ Combiner 6 with 3 Pre-Installed Breakers – X-IQ-AM1-240-6C-3BRK
$2,425.00Available to order Shipping calculated at checkout - EatonSKUMBE2040PV200BTF
Eaton Solar-Ready Meter Main Combo Load Center, 200A, Flush Mount – MBE2040PV200BTF
$433.46Available to order Shipping calculated at checkout - EatonSKUBR816L125RP
Eaton BR Single-Phase Load Center, 125A Main Lug, 8/16 Circuit, NEMA 3R – BR816L125RP
$190.32Available to order Shipping calculated at checkout - EatonSKUBR280
Eaton Type BR Circuit Breaker, 80A, 2-Pole, 120/240V – BR280
$97.58Available to order Shipping calculated at checkout - EatonSKUBR260
Eaton Type BR Circuit Breaker, 60A, 2-Pole, 120/240V – BR260
$27.38Available to order Shipping calculated at checkout - EatonSKUBR240
Eaton Type BR Circuit Breaker, 40A, 2-Pole, 120/240V – BR240
$27.38Available to order Shipping calculated at checkout - EatonSKUBR220
Eaton Type BR Circuit Breaker, 20A, 2-Pole, 120/240V – BR220
$27.38Available to order Shipping calculated at checkout - EatonSKUDG322URB
Eaton Non-Fusible AC Disconnect, 60A, 240V, 3-Pole – DG322URB
$345.37Available to order Shipping calculated at checkout - EatonSKUDG323NRB
Eaton Fusible AC Disconnect, 100A, 240V, 3-Pole – DG323NRB
$729.49Available to order Shipping calculated at checkout - EatonSKUDG223NRB
Eaton Fusible AC Disconnect, 100A, 240V – DG223NRB
$460.91Available to order Shipping calculated at checkout - EatonSKUDG222URB
Eaton Non-Fusible AC Disconnect, 60A, 240V – DG222URB
$279.36Available to order Shipping calculated at checkout - EatonSKUDG221URB
Eaton Non-Fusible AC Disconnect, 30A, 240V – DG221URB
$147.58Available to order Shipping calculated at checkout - PV LabelsSKU05-510
PV Labels 2014 NEC Value Pack, 55 pcs – 05-510
$37.00Available to order Shipping calculated at checkout - PV LabelsSKU05-517
PV Labels 2017 NEC Value Pack, 55 pcs – 05-517
$39.00Available to order Shipping calculated at checkout - PV LabelsSKU05-520
PV Labels 2020 NEC Value Pack, 85 pcs – 05-520
$39.00Available to order Shipping calculated at checkout - PV LabelsSKU05-523
PV Labels 2023 NEC Value Pack, 88 pcs – 05-523
$39.00Available to order Shipping calculated at checkout
This collection covers the AC disconnects, load centers, breakers, combiner boxes, and NEC label packs used to disconnect, protect, and label a solar or battery system. Most of what we sell online here is Eaton outdoor disconnect gear, Eaton BR breakers and load centers, the Enphase IQ Combiner 6, and PV label kits.
- Outdoor AC disconnects (Eaton DG): fusible and non-fusible outdoor safety switches in sizes from 30A to 200A for cutting AC power at the array, inverter, or service. See the product page for pole count and fuse vs non-fuse.
- Breakers and load centers (Eaton BR): 2-pole BR breakers (20A–80A) plus a NEMA 3R BR load center and a solar-ready meter main combo. More panel options also live in load centers and panels.
- Enphase combiner: the IQ Combiner 6 with three pre-installed breakers for Enphase IQ microinverter branch circuits.
- NEC PV labels: value packs sized for 2014, 2017, 2020, and 2023 code cycles, plus a 2020 battery add-on pack.
What these parts do in a solar system
An AC disconnect is a switch that lets you or a utility worker shut off AC power at a clear, labeled point. A breaker opens the circuit when current goes too high. A load center (breaker panel) holds those breakers. A combiner brings several Enphase branch circuits together before the service. PV labels mark disconnects, conduits, and rapid-shutdown equipment so the installation matches the NEC labeling rules your AHJ expects.
How to choose an AC disconnect
- Amps: match or exceed the circuit ampacity your inverter or interconnection design calls for (common sizes here are 30A, 60A, 100A, and 200A).
- Fusible vs non-fusible: fusible models take class-rated fuses for overcurrent protection in the same enclosure; non-fusible models are switches only and need separate overcurrent protection upstream or downstream as the design requires.
- Poles: most residential 120/240V split-phase disconnects are 2-pole; some 3-pole DG models are listed for other AC layouts — read the product title and datasheet.
- Location: these DG switches are outdoor-rated safety switches; still follow the inverter maker and AHJ rules for where the disconnect must sit.
What you may also need
- Usually required with a grid-tied or hybrid inverter: the correct AC disconnect rating, breakers sized per the inverter manual, and PV system labels for your code cycle.
- Often required: cable and conduit hardware from cable and wiring, plus rapid-shutdown equipment from rapid shutdown when the array is on a building.
- For Enphase IQ systems: the IQ Combiner 6 (or the combiner your Enphase design specifies), IQ cable, and an IQ Gateway — see microinverters and Enphase’s current design docs.
- Main service panels: browse load centers and panels when you need meter mains or additional panel stock beyond what is listed here.
For inverter cable, breaker, and fuse sizing notes, use our inverter cable / breaker / fuse sizing guide. For a full bill of materials, request a written quote.
Enclosures, electrical and safety FAQ
Do I need a fusible or non-fusible AC disconnect?
Use a fusible disconnect when the design puts the fuses in that enclosure. Use a non-fusible disconnect when overcurrent protection is already provided by breakers or fuses elsewhere and you only need a visible, lockable AC shutoff. Follow the inverter interconnection drawing and local code — do not guess from amp rating alone.
Are these Eaton DG disconnects for DC solar strings?
The Eaton DG models we list here are AC safety switches (240V-class outdoor disconnects). DC string combiners and DC disconnects are different products. Check the product title for AC vs DC before you order.
What breakers fit the Eaton BR load centers?
The BR load center and meter main in this collection are built for Eaton Type BR breakers. We list common 2-pole BR sizes (20A, 40A, 60A, 80A) used on solar and backup circuits. Confirm bus rating, spaces, and main type on the load-center product page before you pick breakers.
What is the Enphase IQ Combiner 6 for?
It combines multiple Enphase IQ microinverter branch circuits into one enclosure with room for breakers and often the IQ Gateway. The model we sell online includes three pre-installed breakers. Pair it only with an Enphase IQ system designed for that combiner — see Enphase’s current IQ Combiner 6 documentation.
Which NEC label pack should I buy?
Match the pack to the NEC edition your permit is under (2014, 2017, 2020, or 2023). The 2020 battery add-on pack is for extra battery-system labels when your AHJ requires them. Label rules vary by jurisdiction; when unsure, ask your inspector which edition applies.
Why do I still see older MidNite, Victron, or PYTES enclosures in search?
Those SKUs are archived and not for sale. The live assortment in this collection is the Eaton, Enphase, and label products above. If you need a specific combiner or battery enclosure we do not list online, send a written quote request.





















