Tesla

Tesla Backup Switch, 200A Meter-Socket Switch for Powerwall – 1624171-00-X

SKU1624171-00-X

The Tesla Backup Switch (model 1624171-xx-y; this listing is part 1624171-00-X) is the part of a Tesla Powerwall system that connects your home to the grid and disconnects it during an outage. Tesla says it installs behind the utility meter, or in...

$475.00
Available to order

Return policy

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Delivery

Shipping weight 3.3 lb. Shipping, including freight for large items, is calculated at checkout before you pay.

Need help choosing or installing?

Get one hour of personalized help with equipment selection, system questions, commissioning, or troubleshooting. Purchase your session, then use the scheduling link provided after checkout to choose an appointment.

Book a Technical Support Call — $99.00

Product Overview

The Tesla Backup Switch (model 1624171-xx-y; this listing is part 1624171-00-X) is the part of a Tesla Powerwall system that connects your home to the grid and disconnects it during an outage. Tesla says it installs behind the utility meter, or in a standalone meter panel downstream of the utility meter, and it fits ANSI Type 2S meter sockets, ring or ringless.

When the grid goes down, Tesla says the Backup Switch detects the outage automatically and switches the home to backup power from Powerwall. It talks to Powerwall over a wired CAN connection (a communication cable), and its built-in meter lets the Tesla app show how much energy the home is using.

Tesla lists it for Powerwall systems only: Powerwall 3, Powerwall+, and Powerwall 2 with Backup Gateway 2. It is not a general-purpose transfer switch for other battery brands.

Best For

  • Tesla Powerwall home backup: In a Powerwall system, the Backup Switch is the device that separates the home from the grid during an outage so Powerwall can keep power on. Tesla lists Powerwall 3, Powerwall+ and Powerwall 2 with Backup Gateway 2.
  • Homes with a 200 A or smaller service and a Type 2S meter socket: Tesla rates it for 200 A continuous load on 120/240 V split-phase service, with a main breaker of 200 A or less.
  • Meter-side installs: It mounts between the utility meter and the meter socket. Tesla calls installing it behind the utility meter the ideal configuration because it saves time and cost. It adds 2.9 in (74 mm) in front of the meter socket panel.

Key Features & Specifications

Specification Details
Product type Meter-socket backup switch for Tesla Powerwall systems
Model number 1624171-xx-y (this listing: 1624171-00-X)
Continuous load rating 200 A, 120/240 V split-phase (the most current the switch can carry all the time)
Short-circuit current rating 22 kA with breaker (Tesla notes the breaker's maximum supply short-circuit current rating must be equal to or greater than the available fault current)
Communication CAN (wired connection to Powerwall)
AC meter ±0.5% (used for home energy monitoring in the Tesla app)
Product compatibility (per Tesla) Powerwall 2 with Backup Gateway 2, Powerwall+, Powerwall 3
Meter and socket compatibility ANSI Type 2S, ringless or ring type
Service interface Contactor manual override (for service events); reset button
Conduit compatibility 1/2 in NPT
Enclosure; pollution rating NEMA 3R; PD3
Operating temperature −40°C to 50°C (−40°F to 122°F)
Storage temperature −40°C to 85°C (−40°F to 185°F)
Dimensions; weight 176 × 205 × 74 mm (6.9 × 8.1 × 2.9 in); 2.8 lb
Safety standards (per Tesla) UL 414, UL 414 SB, UL 2735, UL 916; FCC Part 15 Class B, ICES 003
Expected service life; warranty (per Tesla) 21 years; 10-year warranty
Source Tesla Backup Switch datasheet dated 2024-04-29 (Tesla Energy Library)

What You May Also Need

Check current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.

Usually required

  • A Tesla Powerwall system listed by Tesla: Powerwall 3, Powerwall+, or Powerwall 2 with Backup Gateway 2.
  • Utility and local inspector approval: Tesla says the Backup Switch can be installed where the utility and the local authority having jurisdiction (AHJ) accept it.
  • A 4-conductor communication cable: Tesla's Powerwall 3 manual routes it from the Backup Switch to Powerwall 3. Tesla's wiring table calls for 18–16 AWG wire on the four connected terminals (12V, ground, CAN+ and CAN−).
  • Conduit or cable and a 1/2 in NPT fitting: Tesla says the communication wiring enters the Backup Switch through its conduit hub using LFNC (liquid-tight flexible nonmetallic conduit) or TCER cable with a 1/2 in NPT fitting. Installer preference, the utility and/or the AHJ decide which one.

May be required

  • A breaker with an adequate short-circuit rating: Tesla's 22 kA rating applies with a breaker whose rating is equal to or greater than the available fault current. Tesla says the breaker can be installed upstream or downstream of the Backup Switch.
  • A standalone meter panel: Tesla says this is an option when the utility does not allow the switch behind the meter, the existing meter socket is not mechanically compatible, or the meter or socket is in poor condition.
  • Solar rapid shutdown devices for Powerwall 3 solar: Tesla's Powerwall 3 datasheet says Powerwall 3 provides solar rapid shutdown using Tesla Mid-Circuit Interrupters (MCIs), lists the MCI-2 High Current (15 A) among its solar shutdown devices, and says systems not subject to rapid shutdown rules must still install one or more MCIs. You can find the Tesla MCI-2 High Current Mid-Circuit Interrupter, 15A on AltE. This is only for systems with solar connected to Powerwall 3.

Optional: related Tesla product (separate purchase)

  • Home EV charging: If you are also planning to charge an electric vehicle at home, you can find the Tesla Universal Wall Connector on AltE. It is not an upgrade or accessory for the Backup Switch, and it is not part of the Backup Switch installation.

Important Considerations

  • Powerwall systems only. Tesla lists compatibility with Powerwall 3, Powerwall+ and Powerwall 2 with Backup Gateway 2. Do not plan to use it with other brands' batteries or inverters.
  • 200 A split-phase, Type 2S. Check that your meter socket is ANSI Type 2S and that the service is 120/240 V split-phase at 200 A or less.
  • Utility rules. Some utilities do not allow meter-socket devices or require their own approval and inspection.
  • Professional installation. Installation at the meter requires utility coordination and a qualified installer.

Frequently Asked Questions

Does the Tesla Backup Switch work with Powerwall 3 and Powerwall 2?

Tesla's Backup Switch datasheet lists Powerwall 3, Powerwall+, and Powerwall 2 with Backup Gateway 2. Tesla's Powerwall 3 datasheet also lists the Backup Switch as one of Powerwall 3's supported islanding devices, along with Gateway 3 and Backup Gateway 2. An islanding device is the equipment that disconnects the home from the grid during an outage. For Powerwall 2, Tesla lists it only with Backup Gateway 2.

Will it fit my meter socket?

Tesla says it fits ANSI Type 2S (Form 2S) meter sockets, ring or ringless, on a 4-jaw meter up to 200 A continuous. Tesla's Powerwall 3 system design guide adds that the meter must be single-phase Form 2S and physically accept the Backup Switch, with a CL100 or CL200 meter rating and a main breaker of 200 A or less.

Tesla also says it is designed to be compatible with most meter sockets, but some older models may be incompatible. It should not be installed where the socket jaws are attached to the bus bar with clips on both sides, or where a set of jaws has a pronounced gap. If the socket is not a fit, Tesla's alternative is a standalone meter panel downstream of the utility meter.

Do I need utility approval?

Yes. Tesla says the Backup Switch can be installed where the utility and the AHJ (your local electrical inspection authority) accept it. If the utility does not allow it behind the meter, Tesla says it can go in a standalone meter panel downstream of the utility meter instead. Tesla also says the grid operator's connection requirements must be met.

What else does the installation need?

According to Tesla, the box includes the Backup Switch, a conduit hub with three captive fasteners, a 4-pin terminal block connector, a sealing ring and a conduit hole cover. The installation also needs a Powerwall system listed by Tesla, a 4-conductor communication cable to Powerwall, and LFNC or TCER cable with a 1/2 in NPT fitting. Depending on the site, it may also need a breaker (upstream or downstream of the switch) whose rating is equal to or greater than the available fault current, and a standalone meter panel. Powerwall 3 systems with solar also need Tesla Mid-Circuit Interrupters in the solar array.

Who should install it?

Tesla's Powerwall 3 and Backup Switch installation manual says Powerwall installation must be carried out only by a competent electrician who is certified by Tesla and trained in dealing with low voltage electricity. Installing the switch behind the meter means removing the utility meter. Tesla warns that service equipment may still be live even when circuits are turned off, and it calls for electrical PPE and an inspection of the meter and socket before installation. Tesla says U.S. installations must follow local codes and the National Electrical Code (ANSI/NFPA 70).