IronRidge BX Module Bonding Jumper, 8" – BX-MB8-M1
SKUBX-MB8-M1
The IronRidge 8" Module Bonding Jumper (BX-MB8-M1) electrically connects the metal frames of two neighboring modules on an IronRidge BX ballasted array. BX chassis are made of a glass-reinforced polymer, not metal, and IronRidge bonds the module frames to each other with...
Couldn't load pickup availability
Need it anyway? Request a written quote. No payment is taken.
Delivery
Shipping weight 0.02 lb. Shipping, including freight for large items, is calculated at checkout before you pay.
Need help choosing or installing?
Get one hour of personalized help with equipment selection, system questions, commissioning, or troubleshooting. Purchase your session, then use the scheduling link provided after checkout to choose an appointment.
- Trusted since 1999
- Ships from US warehouses
- 4.8 stars · 681 Google reviews
Product Overview
The IronRidge 8" Module Bonding Jumper (BX-MB8-M1) electrically connects the metal frames of two neighboring modules on an IronRidge BX ballasted array. BX chassis are made of a glass-reinforced polymer, not metal, and IronRidge bonds the module frames to each other with these jumpers.
IronRidge makes the jumper from tin-plated copper wire with factory-crimped ends. It presses onto the bottom flange of each module.
Bonding ties the metal parts together so a fault current has a path to ground through the array's grounding lug and grounding wire.
Best For
- Module-to-module bonding on BX: IronRidge's manual says to install 8" Module Bonding Jumpers between all modules along the rows.
- Replacing a removed jumper: IronRidge says jumpers are single use, so a new one is needed if one comes off.
Key Features & Specifications
| Specification | Details |
|---|---|
| Product type | Module-to-module bonding jumper, IronRidge BX System |
| Part number | BX-MB8-M1, "8” Module Bonding Jumper" (IronRidge Parts Catalog) |
| Length | 8" |
| Material (per IronRidge) | Tin-plated copper wire, factory-crimped connection |
| Module flange thickness (per IronRidge) | 1.2 to 3.1 mm |
| Installation (per IronRidge) | Press-on, on the bottom flange of the modules |
| Reuse (per IronRidge manual) | Single use only; replace if removed |
| UL listings (per IronRidge manual) | IronRidge's BX manual lists the BX System as UL 2703 and UL 3741 listed (#5014158, #5025960). It says the UL 2703 scope of evaluation includes bonding, grounding, mechanical loading and fire classification. |
| Warranty (per IronRidge) | 25 years for products and 10 years for accessories and electrical junction boxes, from shipment. The 5-year finish warranty does not apply to mill aluminum, pre-plated steel or polymeric products. See IronRidge Limited Warranties and Disclaimer (Warranty.IronRidge.2025). |
| Source | IronRidge Parts Catalog, Version 3.66 (2026); IronRidge 8" Module Bonding Jumper Cut Sheet v1.10; IronRidge BX System Installation Manual, Version 4.2 (2026); IronRidge BX Ballasted System Datasheet, Version 1.30; IronRidge Limited Warranties and Disclaimer (Warranty.IronRidge.2025) |
What You May Also Need
Usually required
- A grounding lug: IronRidge requires one PV module grounding lug (PV-LUG-01-A1) per continuous array.
- 38" Row Bonding Jumpers: IronRidge uses BX-RB38-M1 jumpers to bond each row to the next.
- Enough 8" jumpers: One between each pair of neighboring modules along each row.
May be required
- BX chassis and clamps: 5° chassis, 10° chassis and the BX bottom clamp.
Optional upgrades
- Other mounting parts: See solar panel mounts.
Check current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.
Important Considerations
- Flange thickness. IronRidge lists 1.2 to 3.1 mm. Check your module frame.
- Servicing. IronRidge warns that removing a module may break the bonding path. Install a bonding jumper between the modules on each side of the gap.
- Copper and aluminum. IronRidge says bare copper grounding wire must not touch aluminum or zinc-plated steel parts, to prevent galvanic corrosion.
- Electrical work. IronRidge says electrical installation should be done by a licensed electrician or solar contractor, following NEC 250 and NEC 690.