1
/
of
1
Enphase Energy
Enphase IQ System Controller 3G, 200A, with Generator Support – SC200G111C240US01
Enphase IQ System Controller 3G, 200A, with Generator Support – SC200G111C240US01
Regular price
$3,044.68
Regular price
Sale price
$3,044.68
Unit price
/
per
Couldn't load pickup availability
Product Overview
The Enphase IQ System Controller 3G (SC200G111C240US01) connects the home to grid power, IQ Battery 5P, solar PV, and a supported AC standby generator. It provides microgrid interconnect device (MID) functionality with automatic grid-to-backup transition.
Compared with IQ System Controller 3, the 3G model adds generator support and uses a single 80 A storage OCPD space. Battery capacity on the Americas datasheet is up to 20 kWh without PCS and 40 kWh with PCS.
Best For
- Enphase backup systems that include a standby generator on the IQ System Controller 3G platform.
- Service-entrance or load-center interconnection where a NEMA 3R MID with included System Shutdown Switch is specified (US service-equipment use per the datasheet).
Key Features & Specifications
| Specification | Details |
|---|---|
| Product type | IQ System Controller 3G (MID / backup interconnection) |
| Model number | SC200G111C240US01 |
| Nominal voltage | 240 VAC (±20%) |
| Nominal frequency | 60 Hz (56–63 Hz) |
| Max continuous current | 160 A |
| Max input / output OCPD | 200 A / 200 A |
| Generator circuit OCPD | 80 A (3G only) |
| Storage circuit OCPD | 1 × 80 A |
| PV combiner OCPD | 80 A |
| Internal busbar | 200 A |
| Neutral-forming transformer | 40 A L-N each side; 3,600 VA continuous; 30 A continuous unbalance @ 120 V |
| IQ Battery 5P capacity (datasheet) | Up to 20 kWh without PCS; up to 40 kWh with PCS |
| Enclosure | Outdoor NEMA type 3R, polycarbonate |
| Ambient temperature | −40°C to 50°C (−40°F to 122°F) |
| Dimensions / weight | 19.7 in × 36 in × 9.7 in; 39.4 kg (87 lb) |
| Included | System Shutdown Switch (EP200G-NA-02-RSD), wall bracket, factory quad breaker for NFT/IQ Gateway, accessories kit |
| Warranty (datasheet) | Up to 10 years (RSD switch 5 years) |
| Source | Enphase IQ System Controller 3/3G Americas datasheet DSH-00021-5.0 (IQSC-3-DSH-00021-5.0-EN-US-2024-08-19) |
What You May Also Need
Usually required
- Main/load and DER breakers sized to the job (order separately; datasheet lists Eaton BR / CSR and alternate Siemens/GE options).
- CTRL-SC3-NA-01 for wired CTRL to Combiner 5/5C and IQ Battery 5P.
- IQ Gateway / Combiner path and consumption CTs as required by the system design.
May be required
- IQ Load Controller when essential-load shedding is part of the backup design.
- CT-200-SPLIT (generator integration requires two CTs — CT-200-SPLIT or CT-200-CLAMP — bought separately).
Optional upgrades
- Monitoring & Control: Other monitoring hardware for the same project.
- Generator models: confirm against Enphase’s current Generator integration tech brief (not reproduced here).
Check current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.
Important Considerations
- IQ System Controller 3G supports generator integration; IQ System Controller 3 does not. Do not mix storage OCPD expectations (1×80 A on 3G vs 2×80 A on Controller 3).
- Americas datasheet Compatibility lists IQ Battery 5P, IQ Combiner 5/5C, COMMS-KIT-02, and IQ6/IQ7/IQ8 (and M Series only where IEEE 1547:2018 is not yet adopted). Enphase does not support mixing IQ8 with other microinverter series on the same IQ Gateway.
- Approved for use as service equipment in the United States; not suitable as service equipment in Canada per the datasheet footnote.
- Professional installation required. Follow Enphase instructions and the NEC.
Share