We are no longer offering this product.

The below information is presented for informational purposes only. You may also find similar items in the category.
SHOP ALL PRODUCTS
V

SolarEdge 600W Optimizer for 2 60 Cell Modules, 208V/480V

SolarEdge 600W Optimizer for 2 60 Cell Modules, 208V/480V
SolarEdge 600W Optimizer for 2 60 Cell Modules, 208V/480V
 
Item code Brand name Model number
SEDP600WMC4OPT SolarEdge P600-2NM4ARL

SolarEdge
600W Commercial Power Optimizer
For two 60 Cell Modules
P600-2NM4ARL

The SolarEdge Commercial Power Optimizer is the most cost-effective solution for commercial and large field installations, connecting 2 modules per optimizer. The SolarEdge power optimizers increase energy output from PV systems by constantly tracking the maximum power point (MPPT) of each module individually. Furthermore, the power optimizers monitor the performance of each module and communicate performance data to the SolarEdge monitoring portal for enhanced, cost-effective module-level maintenance. Each power optimizer is equipped with the unique SafeDC™ feature which automatically shuts down modules' DC voltage whenever the inverter or grid power is shut down. The MPPT per module allows for flexible installation design with multiple orientations, tilts and module types in the same string. When working with SolarEdge Inverters, SolarEdge power optimizers automatically maintain a fixed string voltage, allowing installers even greater flexibility with longer strings and strings of different lengths in order to design optimal PV systems. The SolarEdge power optimizers are compatible with c-Si and thin-film modules and have a 25 year warranty.

FEATURES:

  • Ease of installation - simply clip the power optimizer to the module frame or attach to the rail with a single screw
  • Only requires equipment grounding - with a single star washer (included) between the optimizer and the racking (grounding lugs not needed)
  • For Three Phase Inverters
  • Connects two modules per optimizer in series
  • Balance of System cost reduction - 50% less cables, fuses, and combiner boxes, and over 2x longer string lengths possible
  • Up to 25% more harvested energy from your PV system
  • Per-module Maximum Power Point Tracking (MPPT)
  • Superior efficiency (99.5% peak efficiency, 98.8% weighted efficiency)
  • Mitigates all types of modules mismatch-loss, from manufacturing tolerance to partial shading
  • Allows for parallel strings of different lengths or orientations
  • Designed for extreme environmental conditions
  • Advanced, real-time performance measurement
  • Automatic module DC voltage shut-down for installer and firefighter safety. Each optimizer has an internal temperature sensor which detects if it gets over 185 degrees °F - and they shut down, if reached.
  • 25 Year Warranty

ELECTRICAL CHARACTERISTICS:

SPECIFICATIONS P600 Optimizer
(2/60-cell modules)
P700 Optimizer (2/ 72/96-cell modules)
Rated Input DC Power 600W 700W
Absolute Max Input Voltage 96Vdc 125Vdc
MPPT Operating Range 12.5 - 80 Vdc 12.5 - 105 Vdc
Max Short Circuit Current (Isc) 10A
Max DC Input Current 12.5A
Max/Weighted Efficiency 99.5% / 98.6%
Max Output Current 15A
Max Output Voltage 85 Vdc
Safety Output Voltage per Optimizer (during standby) 1 Vdc
INSTALLATION SPECIFICATIONS P600 Optimizer
(2/60-cell modules)
P700 Optimizer (2/ 72/96-cell modules)
Max Allowed System Voltage 1000 Vdc
Input Connector (Modules) MC4 compatible
Output Wire Type/Connector (Optimizers) PV Wire / H4
Output Wire Length 5.9 ft (1.8 m) 6.9 ft (2.1 m)
Operating Temp Range -40 to +85°C / -40 to +185°F
Max/Weighted Efficiency 99.5% / 98.8%
Relative Humidity 0 - 100%
Protection Rating IP65 / NEMA4
Optimizer String Length (Min- Max) - 208V 8 - 30
Module String Length (Min- Max) - 208V 16 - 60
Max Power per String* - 208V 6000W
Optimizer String Length (Min- Max) - 480V 13 - 30
Module String Length (Min- Max) - 480V 26 - 60
Max Power per String* - 480V 12750W

*String length is based on Inverter (208V or 480V)

**NOTE: P300/P400 optimizers can be combined in one string. P600/P700 optimizers can be combined in one string. It is not allowed, however, to mix P600/P700 optimizers with P300/P400 optimizers in one string.

See how easy it is to install and monitor the SolarEdge Solution!


Click here for BBB Business Review ASE NESEA Member
Paypal Visa MasterCard Amex Discover
McAfee SECURE sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams