We are no longer offering this product.
The below information is presented for informational purposes only. You may also find similar items in the category.- FEATURED PRODUCTS
- Solar Panels
- Solar Power Systems
- Productos Solares en Puerto Rico
- Charge Controllers
- Inverters
- Deep Cycle Batteries
- Solar Panel Mounts
- MORE PRODUCTS
- Cables & Wiring
- Enclosures, Electrical & Safety
- Heat Pump Water Heaters
- Inverter Power Panels & PreWired Systems
- Meters, Communications & Site Analysis
- Portable Power Systems
- Solar Water Pumps
- Voltage Converters
- Wind Turbines
- Books & Education
- * Clearance Sale *
- Hot Deals
- Open Box & Refurb Deals
Solar Converters 12/24V-15A Cathodic Protection w/ Meter
Item code | Brand name | Model number |
SORCP12/24-15MT | Solar Converters | CP 12/24-15MT |
Solar
Converters
CP12/24-15
Used to control the current injected into the ground bed to prevent the rusting of iron and/or steel objects inbedded in the ground. This highly efficient highly and stable multiple control mode unit switches automatically between the various control modes to maintain the proper structure potential as the ground bed resistance changes with operating conditions.
Features
- Ultra high efficiency >96 % typical
- Excellent Control Features with automatic switchover
- Constant Voltage
- Constant Current
- Half Cell Voltage Regulation
- Transient Protection on all connections
- Ideal for solar powered battery backed cathodic protection systems very high efficiency maximizes the performance of your solar investment while minimizing cost
- User adjustable output voltage, current limit and half cell voltage regulation with automatic crossover
- Remote control (instant on/off) and metering options available for sequenced operation
Electrical Specifications
Input Voltage | 10 V to 40 V |
User adjustable Output Voltage | 2.0 to 32.0 Volts |
Output Current User adjustable |
0 .1 to 20 amps |
Half cell Voltage User adjustable |
0.2 to 3.0 Volts |
Ripple at load (mv rms) | 20 |
Efficiency | >96% |
Transient Protection | all inputs and outputs protected and tested |
Transient response (10% - 90%) | 20 ms to return to regulation |
User Controls | voltage, current limit and half cell regulation |
Mechanical Specifications
Open Frame style for mount in NEMA enclosures.
Dimensions: 4.88" X 4.88" X 1.5"
Weight: approx 2 lbs.
Temperature Range: -40 deg C to 75 deg C
It is recommended, as with all electronics, that the unit
not be placed in direct sunshine.
Terminations:
- Power Eurostyle Terminal Strip, Wire size: #10 AWG
- Signal Eurostyle Terminal Strip, Wire size: #18 AWG
Humidity: 90 % non-condensing, designed and tested for operation in a NEMA 12, 4, 4X enclosure = weatherproof
Application Notes
1. It is recommended that the unit be placed in a system
that has an LVD capability, unit shuts down under 10 V input
2. When not operating in half cell voltage regulation, short half cell sense
to itself
3. Addition of simple transformer and diode bridge, unit becomes AC powered