KiloVault® HAB™ 7.5kWh LiFePO4 Battery Storage System
The KiloVault® HAB™ Series wall-mount energy storage system is a 48-volt, 7.5 kilowatt-hour battery designed for trouble-free mounting and easy integration with other system components. Up to 14 units can be used together for additional energy storage capacity.
KiloVault HAB 7.5kW Lithium Battery Includes:
- Includes battery unit
- Mounting brackets and hardware
- Communications cables
- Ventilation options with two housing plate types - vented plates for improved performance in warmer climates and solid plates to swap in for improved weather resistance
- Box removal handles
Video: Unboxing and wall-mounting a HAB
KiloVault HAB 7.5kW Lithium Battery Features
- Safe LiFePO4 battery cells
- Long cycle life with up to 6000 cycles (see charging profile table for details)
- Closed loop communication available with Sol-Ark 5K/8K/12K inverters and Schneider XW Pro inverters - see DOCUMENTS tab above
- Wall-mounted all-in-one design with integrated lift handles
- Integrated WiFi communications
- Advanced high/low temperature cycle performance
- Intelligent LED & LCD display
- Ventilation options provide improved performance in warmer climates, with solid plates to swap in for weather resistance
- Large wiring access panel offers more space for making connections
- Supports up to 14 HAB battery modules in parallel
- ETL certified to UL Standard 1973
- ETL certified to UL Standard 9540/9540A when paired with a Sol-Ark 12K or Schneider XW Pro inverter in our HAB/Sol-Ark 12K ESS kit and HAB/XW Pro ESS kit
- 10-year limited warranty (duration of warranty is determined by charging profile - see table below and warranty document on Documents tab for details)
- Be sure to register your KiloVault battery to get the latest updates, as well as for tech support
KiloVault HAB 7.5kW Lithium Battery Tech Specs
Rated Energy Capacity (Watt-Hours) |
7500 Wh |
DC Voltage Nominal |
51.2V |
Nominal Amp-Hour Capacity |
150 Ah |
Optimal Charger/Inverter Settings |
Bulk/Absorption: 56 V Float: NA (2-stage-no-float for charging cycle) Low Voltage Cut-Off: 48.2V Equalization: Disable. Do not use. (Battery will shut down into protection mode) |
Maximum Battery Cut-Off Voltage |
57.0V |
Minimum Battery Cut-Off Voltage |
48.2V |
Max Continuous Charge Current* |
50A |
Max Continuous Discharge Current* |
60A |
Peak Discharge Current (<3 secs) |
500A |
Operating Temperature |
Charging: 32 - 113°F (0 - 45°C) Discharging: -4 to 140°F (-20 to 60°C) |
Storage Temperature |
-4 to 110° F (-20° C to 45° C) |
Cycle Life* |
6000 (80% DoD) |
Battery Management System |
BMS firmware and hardware have been updated to allow V2 and V3 versions to be used with V4, if expansion is needed. |
Monitoring |
Wireless on-site detailed battery status monitoring |
Communications |
Integrated HAB to Inverter Modbus communications w RJ45 on both ends of cable using the RS-485 standard. Integrated HAB to HAB CAN bus communications w RJ45 on both ends of cable. |
Self-Discharge Rate |
≤3% per month *Only achieved if HAB is put to sleep by pressing down the power button for 10 seconds, otherwise standard shutdown can cause self-discharge to be as high as 9% per month |
Maximum Configuration |
14 batteries in parallel |
Compatibility |
All versions of HABs can communicate with each other, as long as they are updated with the latest firmware versions. (*V1 updates can not be done over internet so please call in to have special update kit sent). Conditions: When adding in parallel configuration to an older bank, the newest HAB version must be the leader. HAB Communication Cable is required. |
Max Time Between Charges |
6 months |
Dimensions (L x W x H) |
9.5" x 22.5" x 32" |
Weight |
230 lbs |
Ingress Rating |
IP54 with vented plates IP55 with solid plates |
Certifications |
Unit Certified ETL to UL Standard 1973; UL1642; UN38.3; IEC62619; OSHA 18001/ISO45001; ISO 9001/1400 |
*Manufacturer Operating Parameters by Charging Profile
|
10-Year Extended Life Warranty |
7.5-Year Extended Charge Rate Warranty |
Low Voltage Cut-Off |
48.2V |
High Voltage Cut-Off |
57.0V |
Discharge Rate |
60A |
150A |
Charge Rate |
50A |
120A |
Cycle Life |
6000 cycles (80% DoD) |
4000 cycles (80% DoD) |