{"product_id":"tesla-backup-switch-200a-meter-socket-switch-for-powerwall-1624171-00-x","title":"Tesla Backup Switch, 200A Meter-Socket Switch for Powerwall – 1624171-00-X","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Tesla Backup Switch (model 1624171-xx-y; this listing is part 1624171-00-X) is the part of a Tesla Powerwall system that connects your home to the grid and disconnects it during an outage. Tesla says it installs behind the utility meter, or in a standalone meter panel downstream of the utility meter, and it fits ANSI Type 2S meter sockets, ring or ringless.\u003c\/p\u003e\n\u003cp\u003eWhen the grid goes down, Tesla says the Backup Switch detects the outage automatically and switches the home to backup power from Powerwall. It talks to Powerwall over a wired CAN connection (a communication cable), and its built-in meter lets the Tesla app show how much energy the home is using.\u003c\/p\u003e\n\u003cp\u003eTesla lists it for Powerwall systems only: Powerwall 3, Powerwall+, and Powerwall 2 with Backup Gateway 2. It is not a general-purpose transfer switch for other battery brands.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTesla Powerwall home backup:\u003c\/strong\u003e In a Powerwall system, the Backup Switch is the device that separates the home from the grid during an outage so Powerwall can keep power on. Tesla lists Powerwall 3, Powerwall+ and Powerwall 2 with Backup Gateway 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHomes with a 200 A or smaller service and a Type 2S meter socket:\u003c\/strong\u003e Tesla rates it for 200 A continuous load on 120\/240 V split-phase service, with a main breaker of 200 A or less.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeter-side installs:\u003c\/strong\u003e It mounts between the utility meter and the meter socket. Tesla calls installing it behind the utility meter the ideal configuration because it saves time and cost. It adds 2.9 in (74 mm) in front of the meter socket panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eMeter-socket backup switch for Tesla Powerwall systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel number\u003c\/td\u003e\n\u003ctd\u003e1624171-xx-y (this listing: 1624171-00-X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous load rating\u003c\/td\u003e\n\u003ctd\u003e200 A, 120\/240 V split-phase (the most current the switch can carry all the time)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current rating\u003c\/td\u003e\n\u003ctd\u003e22 kA with breaker (Tesla notes the breaker's maximum supply short-circuit current rating must be equal to or greater than the available fault current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eCAN (wired connection to Powerwall)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC meter\u003c\/td\u003e\n\u003ctd\u003e±0.5% (used for home energy monitoring in the Tesla app)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct compatibility (per Tesla)\u003c\/td\u003e\n\u003ctd\u003ePowerwall 2 with Backup Gateway 2, Powerwall+, Powerwall 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter and socket compatibility\u003c\/td\u003e\n\u003ctd\u003eANSI Type 2S, ringless or ring type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService interface\u003c\/td\u003e\n\u003ctd\u003eContactor manual override (for service events); reset button\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit compatibility\u003c\/td\u003e\n\u003ctd\u003e1\/2 in NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure; pollution rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R; PD3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to 50°C (−40°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to 85°C (−40°F to 185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions; weight\u003c\/td\u003e\n\u003ctd\u003e176 × 205 × 74 mm (6.9 × 8.1 × 2.9 in); 2.8 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety standards (per Tesla)\u003c\/td\u003e\n\u003ctd\u003eUL 414, UL 414 SB, UL 2735, UL 916; FCC Part 15 Class B, ICES 003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpected service life; warranty (per Tesla)\u003c\/td\u003e\n\u003ctd\u003e21 years; 10-year warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eTesla Backup Switch datasheet dated 2024-04-29 (Tesla Energy Library)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA Tesla Powerwall system listed by Tesla:\u003c\/strong\u003e Powerwall 3, Powerwall+, or Powerwall 2 with Backup Gateway 2.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility and local inspector approval:\u003c\/strong\u003e Tesla says the Backup Switch can be installed where the utility and the local authority having jurisdiction (AHJ) accept it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA 4-conductor communication cable:\u003c\/strong\u003e Tesla's Powerwall 3 manual routes it from the Backup Switch to Powerwall 3. Tesla's wiring table calls for 18–16 AWG wire on the four connected terminals (12V, ground, CAN+ and CAN−).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit or cable and a 1\/2 in NPT fitting:\u003c\/strong\u003e Tesla says the communication wiring enters the Backup Switch through its conduit hub using LFNC (liquid-tight flexible nonmetallic conduit) or TCER cable with a 1\/2 in NPT fitting. Installer preference, the utility and\/or the AHJ decide which one.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA breaker with an adequate short-circuit rating:\u003c\/strong\u003e Tesla's 22 kA rating applies with a breaker whose rating is equal to or greater than the available fault current. Tesla says the breaker can be installed upstream or downstream of the Backup Switch.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA standalone meter panel:\u003c\/strong\u003e Tesla says this is an option when the utility does not allow the switch behind the meter, the existing meter socket is not mechanically compatible, or the meter or socket is in poor condition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar rapid shutdown devices for Powerwall 3 solar:\u003c\/strong\u003e Tesla's Powerwall 3 datasheet says Powerwall 3 provides solar rapid shutdown using Tesla Mid-Circuit Interrupters (MCIs), lists the MCI-2 High Current (15 A) among its solar shutdown devices, and says systems not subject to rapid shutdown rules must still install one or more MCIs. You can find the \u003ca href=\"\/products\/tesla-mci-2-high-current-mid-circuit-interrupter-15a-rapid-shutdown-device\"\u003eTesla MCI-2 High Current Mid-Circuit Interrupter, 15A\u003c\/a\u003e on AltE. This is only for systems with solar connected to Powerwall 3.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional: related Tesla product (separate purchase)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHome EV charging:\u003c\/strong\u003e If you are also planning to charge an electric vehicle at home, you can find the \u003ca href=\"\/products\/tesla-universal-wall-connector-ev-charger-24-ft-cord-1734412-02-x\"\u003eTesla Universal Wall Connector\u003c\/a\u003e on AltE. It is not an upgrade or accessory for the Backup Switch, and it is not part of the Backup Switch installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePowerwall systems only.\u003c\/strong\u003e Tesla lists compatibility with Powerwall 3, Powerwall+ and Powerwall 2 with Backup Gateway 2. Do not plan to use it with other brands' batteries or inverters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e200 A split-phase, Type 2S.\u003c\/strong\u003e Check that your meter socket is ANSI Type 2S and that the service is 120\/240 V split-phase at 200 A or less.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility rules.\u003c\/strong\u003e Some utilities do not allow meter-socket devices or require their own approval and inspection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional installation.\u003c\/strong\u003e Installation at the meter requires utility coordination and a qualified installer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eDoes the Tesla Backup Switch work with Powerwall 3 and Powerwall 2?\u003c\/h4\u003e\n\u003cp\u003eTesla's Backup Switch datasheet lists Powerwall 3, Powerwall+, and Powerwall 2 with Backup Gateway 2. Tesla's Powerwall 3 datasheet also lists the Backup Switch as one of Powerwall 3's supported islanding devices, along with Gateway 3 and Backup Gateway 2. An islanding device is the equipment that disconnects the home from the grid during an outage. For Powerwall 2, Tesla lists it only with Backup Gateway 2.\u003c\/p\u003e\n\u003ch4\u003eWill it fit my meter socket?\u003c\/h4\u003e\n\u003cp\u003eTesla says it fits ANSI Type 2S (Form 2S) meter sockets, ring or ringless, on a 4-jaw meter up to 200 A continuous. Tesla's Powerwall 3 system design guide adds that the meter must be single-phase Form 2S and physically accept the Backup Switch, with a CL100 or CL200 meter rating and a main breaker of 200 A or less.\u003c\/p\u003e\n\u003cp\u003eTesla also says it is designed to be compatible with most meter sockets, but some older models may be incompatible. It should not be installed where the socket jaws are attached to the bus bar with clips on both sides, or where a set of jaws has a pronounced gap. If the socket is not a fit, Tesla's alternative is a standalone meter panel downstream of the utility meter.\u003c\/p\u003e\n\u003ch4\u003eDo I need utility approval?\u003c\/h4\u003e\n\u003cp\u003eYes. Tesla says the Backup Switch can be installed where the utility and the AHJ (your local electrical inspection authority) accept it. If the utility does not allow it behind the meter, Tesla says it can go in a standalone meter panel downstream of the utility meter instead. Tesla also says the grid operator's connection requirements must be met.\u003c\/p\u003e\n\u003ch4\u003eWhat else does the installation need?\u003c\/h4\u003e\n\u003cp\u003eAccording to Tesla, the box includes the Backup Switch, a conduit hub with three captive fasteners, a 4-pin terminal block connector, a sealing ring and a conduit hole cover. The installation also needs a Powerwall system listed by Tesla, a 4-conductor communication cable to Powerwall, and LFNC or TCER cable with a 1\/2 in NPT fitting. Depending on the site, it may also need a breaker (upstream or downstream of the switch) whose rating is equal to or greater than the available fault current, and a standalone meter panel. Powerwall 3 systems with solar also need Tesla Mid-Circuit Interrupters in the solar array.\u003c\/p\u003e\n\u003ch4\u003eWho should install it?\u003c\/h4\u003e\n\u003cp\u003eTesla's Powerwall 3 and Backup Switch installation manual says Powerwall installation must be carried out only by a competent electrician who is certified by Tesla and trained in dealing with low voltage electricity. Installing the switch behind the meter means removing the utility meter. Tesla warns that service equipment may still be live even when circuits are turned off, and it calls for electrical PPE and an inspection of the meter and socket before installation. Tesla says U.S. installations must follow local codes and the National Electrical Code (ANSI\/NFPA 70).\u003c\/p\u003e\n","brand":"Tesla","offers":[{"title":"Default Title","offer_id":48037624381659,"sku":"1624171-00-X","price":475.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/GUID-085CDF00-3A2A-4617-82BF-A2BE72A53368-online-en-US.png?v=1765219691","url":"https:\/\/www.altestore.com\/products\/tesla-backup-switch-200a-meter-socket-switch-for-powerwall-1624171-00-x","provider":"AltE Store","version":"1.0","type":"link"}