{"product_id":"solis-s6-16kw-48v-hybrid-inverter-120-240v-split-phase-s6-eh2p16k03-sv-yd-l-us","title":"Solis S6 16kW 48V Hybrid Inverter, 120\/240V Split-Phase – S6-EH2P16K03-SV-YD-L-US","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Solis S6-EH2P16K03-SV-YD-L-US is a 16 kW, 48 V low-voltage hybrid inverter for homes on 120\/240 V split-phase service. It combines solar charging (three MPPTs), a 48 V battery inverter\/charger, grid connection, a 200 A passthrough for whole-home backup and a smart port for a generator or AC-coupled solar.\u003c\/p\u003e\n\u003cp\u003eSolis describes it as able to run on-grid, off-grid or as a microgrid. The battery is a 48 V-class bank (40–60 V), not a high-voltage battery, and backup can cover dedicated loads or the whole home.\u003c\/p\u003e\n\u003cp\u003eSolis sells this inverter with or without a built-in rapid shutdown transmitter. Solis's user manual (Version 2.7, March 5, 2026) lists the part number without a suffix (this listing) as the version with no transmitter; -APST (APsmart) and -RSS (Tigo) are the built-in options. Solis's 2026 Master Product Compatibility Sheet (June 8, 2026) confirms that a suffix is needed for an integrated transmitter. Without a built-in transmitter, a compatible external transmitter is installed instead.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarger homes on 120\/240 V split-phase service:\u003c\/strong\u003e 16 kW rated output, with backup output at the same rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhole-home backup with a 48 V battery:\u003c\/strong\u003e The 200 A continuous passthrough lets the inverter sit between the utility and the loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator backup:\u003c\/strong\u003e The smart port accepts a generator up to 24 kW and 100 A, per Solis's datasheet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProjects that will use an external rapid shutdown transmitter:\u003c\/strong\u003e Solis's manual describes installing an external Tigo or APsmart transmitter with this inverter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003e48 V low-voltage hybrid inverter (on-grid, off-grid and microgrid operation), split-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ ordering part number\u003c\/td\u003e\n\u003ctd\u003eS6-EH2P16K03-SV-YD-L-US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output (grid and backup)\u003c\/td\u003e\n\u003ctd\u003e16 kW \/ 16 kVA; 240 V L1-L2 (120\/240 V split-phase); 66.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup surge\u003c\/td\u003e\n\u003ctd\u003e3× rated power for 1 s; 2× rated power for 10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackup switch time\u003c\/td\u003e\n\u003ctd\u003eLess than 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid passthrough\u003c\/td\u003e\n\u003ctd\u003e200 A maximum continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid input voltage range; frequency\u003c\/td\u003e\n\u003ctd\u003e211–264 V; 58.8–61.2 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV input\u003c\/td\u003e\n\u003ctd\u003e3 MPPTs, 2 strings each; recommended maximum PV power 25.6 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT range; start-up voltage; maximum DC input\u003c\/td\u003e\n\u003ctd\u003e100–450 V (full load 186–450 V); 100 V; 550 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per MPPT\u003c\/td\u003e\n\u003ctd\u003e40 A maximum input; 50 A maximum short-circuit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003eLi-ion or lead-acid; 40–60 V; 290 A maximum charge\/discharge; CAN and RS485 communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGenerator input\u003c\/td\u003e\n\u003ctd\u003e24 kW maximum; 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eMaximum 96.02%; CEC 95.45%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eGround fault monitoring, integrated AFCI, PV reverse-polarity protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure; temperature\u003c\/td\u003e\n\u003ctd\u003eType 4X; −25°C to 60°C (−13°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions; weight\u003c\/td\u003e\n\u003ctd\u003e534 × 930 × 297 mm (21.02 × 36.61 × 11.69 in); 65.8 kg (145.06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMonitoring\u003c\/td\u003e\n\u003ctd\u003eSolisCloud; 7.0 in LCD, Bluetooth and app; RS485, with optional cellular, Wi-Fi or LAN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications (per Solis)\u003c\/td\u003e\n\u003ctd\u003eUL 1741, UL 1741 SB, UL 1741 PVRSS, UL 1699B, UL 1998, CSA C22.2 107.1; IEEE 1547-2018, IEEE 1547.1-2020, CA Rule 21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eSolis S6-EH2P(9.6-16)K03-SV-YD-L-US datasheet V2.2 (PDF dated March 16, 2026); Solis's user manual (Version 2.7, March 5, 2026); Solis's 2026 Master Product Compatibility Sheet (June 8, 2026)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA rapid shutdown transmitter and matching receivers (rooftop arrays):\u003c\/strong\u003e Solis's manual lists this part number as the version with no built-in transmitter. For the S6-EH2P, Solis's 2026 Master Product Compatibility Sheet (June 8, 2026) lists Tigo TS4-A-F or TS4-A-2F receivers (Tigo RSS transmitter) and APsmart RSD-S-PLC-A or RSD-D-20 receivers (APsmart transmitter); it lists the Tigo CCA with the TS4-A-O optimizer as compatible but not integrated. Brands cannot be mixed, and Solis warns that installing components not on its list can void the inverter warranty. Examples: the \u003ca href=\"\/products\/tigo-492-00000-51-single-core-100-amp-rss-din-rail-transmitter-kit\"\u003eTigo RSS transmitter kit\u003c\/a\u003e with \u003ca href=\"\/products\/tigo-ts4-a-f-module-level-fire-protection-with-rapid-shutdown-capability-with-1-2m-mc4-cables\"\u003eTigo TS4-A-F\u003c\/a\u003e receivers, or the \u003ca href=\"\/products\/aps-apsmart-transmitter-plc-outdoor-kit-single-core-408006\"\u003eAPsmart Transmitter PLC kit\u003c\/a\u003e with APsmart RSD-S-PLC-A or RSD-D-20 receivers per Solis's June 2026 compatibility sheet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA 48 V battery bank:\u003c\/strong\u003e Solis publishes a list of closed-loop (CAN) batteries for this inverter; check the current list for the battery model and quantity. Solis's user manual (Version 2.7, March 5, 2026) also allows a 48–52 V lithium or lead-acid battery in open-loop mode. In that mode the inverter cannot read battery state of charge or faults, so confirm the battery warranty covers open-loop use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery cables and DC overcurrent protection:\u003c\/strong\u003e Size them for up to 290 A, following Solis's and the battery maker's manuals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent transformers (CTs) or an energy meter:\u003c\/strong\u003e Solis's user manual (Version 2.7, March 5, 2026) says self-use mode works only with CTs or a meter installed. Two 250 A split-core CTs (CHINT NCTK-24) come with the inverter, per that manual and Solis's June 2026 compatibility sheet. The manual also calls for a CHINT energy meter in some layouts, for example when more than one inverter is installed; check the manual's meter conditions for your site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/disconnects-breakers\"\u003eDisconnects and breakers\u003c\/a\u003e:\u003c\/strong\u003e Additional AC disconnects or breakers may be needed depending on whether you back up the whole home or selected loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA backup loads panel:\u003c\/strong\u003e Needed when you back up dedicated loads rather than the whole home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGenerator:\u003c\/strong\u003e Connects to the smart port (24 kW, 100 A maximum per Solis). Solis's manual also covers generator dry-contact control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCellular, Wi-Fi or LAN module:\u003c\/strong\u003e Optional communication for SolisCloud monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo built-in transmitter.\u003c\/strong\u003e Solis's manual and its June 2026 compatibility sheet both say an integrated transmitter is ordered with a suffix (-APST or -RSS), so this no-suffix part number has none, even though the series datasheet lists an integrated transmitter. Check the unit label before ordering rapid shutdown equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e48 V battery, not high-voltage.\u003c\/strong\u003e This inverter takes a 40–60 V battery. High-voltage battery systems are not compatible with it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120\/240 V split-phase only.\u003c\/strong\u003e The datasheet lists 240 V L1-L2 output with a 211–264 V grid range. It is not a 208 V three-phase inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize and weight.\u003c\/strong\u003e At 145 lb, the inverter needs a wall and mounting method that can carry it.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional installation.\u003c\/strong\u003e Grid-connected hybrid systems need utility interconnection approval and are installed by qualified installers under local electrical codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Solis","offers":[{"title":"Default Title","offer_id":49185968062683,"sku":"S6-EH2P16K03-SV-YD-L-US","price":4995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/1760402872236_11fa01ec-01df-427e-b648-e10651e587e3_1.png?v=1787861476","url":"https:\/\/www.altestore.com\/products\/solis-s6-16kw-48v-hybrid-inverter-120-240v-split-phase-s6-eh2p16k03-sv-yd-l-us","provider":"AltE Store","version":"1.0","type":"link"}