{"product_id":"sld-tech-st-255q-12cid2-qc-255w-12v-class-i-div-2-monocrystalline-solar-panel","title":"SLD Tech ST-255Q-12CID2-QC 255W 12V Class I Div 2 Monocrystalline Solar Panel","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe SLD Tech ST-255Q-12CID2-QC is a 255 W monocrystalline solar panel with a nominal 12 V output. \"Nominal 12 V\" means the panel is built to charge a 12 V battery bank through a charge controller. Its working voltage (Vmp) is 20.29 V, which is higher than the battery voltage so the controller has room to charge.\u003c\/p\u003e\n\u003cp\u003eThis model is rated for hazardous locations. SLD's datasheet shows a CSA certification mark (file 272637) for Class I, Division 2, Groups A, B, C and D, with temperature code T3C. Class I, Division 2 areas are places where flammable gases or vapors are not normally present but could be under abnormal conditions.\u003c\/p\u003e\n\u003cp\u003eThe panel has 72 monocrystalline cells. SLD describes the construction as a heavy-duty anodized aluminum frame with low-iron tempered glass. It measures about 67.9 × 30.2 inches and weighs 15.18 kg (33.46 lb).\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous-location sites:\u003c\/strong\u003e SLD says this CID2-rated panel is suitable for industries that are at risk of gas explosions. Use it where the area is classified Class I, Division 2 and equipment must carry that rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid 12 V power for remote equipment:\u003c\/strong\u003e Charges a 12 V battery bank through a charge controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacing or adding to an existing CID2 array:\u003c\/strong\u003e Use the same model so the panel ratings and hazardous-location rating match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eMonocrystalline solar panel rated for Class I, Division 2 hazardous locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ manufacturer part number\u003c\/td\u003e\n\u003ctd\u003eST-255Q-12CID2-QC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated power (STC)\u003c\/td\u003e\n\u003ctd\u003e255 W. STC (Standard Test Conditions) is the lab test used to rate every panel the same way.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal output\u003c\/td\u003e\n\u003ctd\u003e12 V (for charging a 12 V battery through a charge controller)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage \/ current at max power (Vmp \/ Imp)\u003c\/td\u003e\n\u003ctd\u003e20.29 V \/ 12.57 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOpen-circuit voltage (Voc)\u003c\/td\u003e\n\u003ctd\u003e23.55 V at STC. This is the panel's voltage with nothing connected. It goes up in cold weather.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit current (Isc)\u003c\/td\u003e\n\u003ctd\u003e13.22 A at STC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature coefficients\u003c\/td\u003e\n\u003ctd\u003ePmax −(0.5 ± 0.05)%\/°C; Voc −(80 ± 10) mV\/°C; Isc +(0.065 ± 0.015)%\/°C. Power drops a little as the panel heats up, and voltage rises in the cold.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNOCT\u003c\/td\u003e\n\u003ctd\u003e47 ± 2°C (nominal operating cell temperature, for reference)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−40°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum system voltage\u003c\/td\u003e\n\u003ctd\u003e600 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolar cells\u003c\/td\u003e\n\u003ctd\u003e72 monocrystalline cells (4 × 18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e1,725 × 768 mm (67.9 × 30.24 in) length and width. SLD's datasheet gives two different frame thicknesses for this model, so check the panel you receive.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e15.18 kg (33.46 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eAnodized aluminum frame; low-iron tempered glass (as described by SLD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous location rating\u003c\/td\u003e\n\u003ctd\u003eClass I, Division 2, Groups A, B, C and D; CSA certification mark, file 272637 (shown on SLD's datasheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature code\u003c\/td\u003e\n\u003ctd\u003eT3C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire rating\u003c\/td\u003e\n\u003ctd\u003eModule fire performance Type 1 (US); fire resistance rating Class C (Canada)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV module application class\u003c\/td\u003e\n\u003ctd\u003eClass A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e1-year limited warranty on materials and manufacturing and a 10-year workmanship warranty (panels 100 W and up). Performance warranty: at least 90% of rated power at 10 years and at least 80% at 25 years. Source: SLD's Warranty \u0026amp; Policy page (last updated April 29, 2026); the datasheet also lists a 10-year product workmanship warranty and a 25-year power warranty.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar charge controller:\u003c\/strong\u003e Sits between the panel and the battery and controls charging. Choose a controller rated for your battery voltage and for this panel's Voc and Isc. SLD's installation manual (May 31, 2023) says to multiply the panel's Isc and Voc by 1.25 when sizing connected equipment, conductors and fuses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery bank:\u003c\/strong\u003e A 12 V battery bank stores the energy for use when the sun is down. Battery chemistry and charge settings must match the controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting hardware:\u003c\/strong\u003e Holds the panel at the right angle. For roof or flat-roof installs, see \u003ca href=\"\/collections\/solar-panel-mounts\"\u003erails, tilt legs, module clamps and roof attachments\u003c\/a\u003e. For a pole or wall mount, choose one rated for this panel's size and weight. Choose clamps or bolts that fit this panel's frame height, which you should measure on the panel you receive.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/cable-wiring\"\u003eCables and wiring\u003c\/a\u003e:\u003c\/strong\u003e Wire from the panel to the controller. SLD's documents for this model do not name the connector type, so check the connectors on the panel you receive before buying extension cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/disconnects-breakers\"\u003eDisconnects and breakers\u003c\/a\u003e:\u003c\/strong\u003e Fuses or breakers between the panel, controller and battery protect the wiring and let you isolate the system for service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding hardware:\u003c\/strong\u003e Bond the frame to ground as your electrical code and the site's hazardous-location rules require.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdditional matching panels:\u003c\/strong\u003e More panels of the same model add charging power. SLD's installation manual (May 31, 2023) recommends no more than 3 panels in parallel. How many panels you can wire in series is limited by this panel's 600 V maximum system voltage, its open-circuit voltage (Voc) at your site's coldest temperature and your charge controller's input limit. Size strings per the NEC and SLD's datasheet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery monitor:\u003c\/strong\u003e Shows battery state of charge and charging current so you can see how the system is performing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe whole installation must suit the hazardous location.\u003c\/strong\u003e The panel's Class I, Division 2 rating covers the panel only. The charge controller, wiring methods, connectors, enclosures and any other equipment in the classified area must also be suitable for that location, and the installation must be approved by your local code official (AHJ).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the temperature code.\u003c\/strong\u003e The panel is rated T3C. Confirm that this temperature code is acceptable for the specific gases or vapors present at your site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature is −40°C to 65°C.\u003c\/strong\u003e This is the range on SLD's datasheet for this model, which is narrower than many standard panels. Check it against your site conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting.\u003c\/strong\u003e SLD's installation manual (May 31, 2023) says to fasten each panel at a minimum of 6 points on the long sides of the frame, never by the short sides. Use the existing frame holes; SLD says drilling additional holes voids the warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold-weather voltage.\u003c\/strong\u003e Voc rises as temperature drops. When wiring panels in series, check that the total voltage at your site's coldest temperature stays under the controller's limit and the panel's 600 V maximum system voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatching panels.\u003c\/strong\u003e SLD's manual says panels in series must have the same current rating and panels in parallel must have the same voltage rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQualified installer.\u003c\/strong\u003e SLD's manual says installation, setup, maintenance and repairs must be carried out by qualified and authorized persons.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"SLD Tech","offers":[{"title":"Default Title","offer_id":49257944383707,"sku":"ST-255Q-12CID2-QC","price":385.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/ST-255Q-12CID2-QC-product.png?v=1788903742","url":"https:\/\/www.altestore.com\/products\/sld-tech-st-255q-12cid2-qc-255w-12v-class-i-div-2-monocrystalline-solar-panel","provider":"AltE Store","version":"1.0","type":"link"}