{"product_id":"quick-mount-pv-jaybox-junction-box-comp-shingle-roof-mount-qm-jbx-rf02-b1","title":"Quick Mount PV JayBox Junction Box, Comp Shingle Roof Mount – QM-JBX-RF02-B1","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IronRidge QuickMount JayBox (QM-JBX-RF02-B1) is the deck-mounted version of the JayBox photovoltaic junction box, made for composition shingle roofs. It comes with a black aluminum flashing and self-drilling wood screws, and allows a waterproof conduit pass-through into the attic, per IronRidge.\u003c\/p\u003e\n\u003cp\u003eIronRidge molds the JayBox from SABIC NORYL resin. Its hinged lid stays open on roof slopes up to 70°, per IronRidge. Because the enclosure is nonconductive, IronRidge says there is no need to ground the box or its lid.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComp shingle roofs at 2:12 and steeper:\u003c\/strong\u003e IronRidge's roof slope range for the JayBox.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAttic pass-through wiring:\u003c\/strong\u003e Up to 2 attic pass-through conduit fittings, 1\/2\" to 1-1\/4\", per IronRidge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePhotovoltaic junction box, comp shingle roof (deck) mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eQM-JBX-RF02-B1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL \/ CSA (as worded in IronRidge manual)\u003c\/td\u003e\n\u003ctd\u003eUL 1741 LISTED #5021605. Photovoltaic Junction Box Conforms to UL STD 1741 and Certified to CSA STD C22.2 No. 107.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical ratings (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003e1500 V maximum system voltage; 100 A maximum total current (Isc); 30 A maximum per string (Isc); up to 4 input circuits, combined not to exceed 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure rating (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eType 3R Rainproof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable wire sizes (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eInputs 12–10 AWG; outputs 12–8 AWG; ground 10–6 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior dimensions; flashing (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eBox 8\" W × 8\" D × 3\" H, 150 in³; flashing 12\" W × 9\" D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoof (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eRoof slope 2:12 and above; attic pass-through fittings 1\/2\"–1-1\/4\", max 2; max side wall fitting 1-1\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater seal ratings (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eUL 441; TAS 100(A)-95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded (per IronRidge cut sheet)\u003c\/td\u003e\n\u003ctd\u003eLid; housing; EPDM gasket; black 3000-series aluminum flashing; 2 self-drilling #12 wood screws; DIN rail; ground bar kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eSABIC NORYL resin; nonconductive, so IronRidge says the box and lid need no grounding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTorque (per IronRidge manual)\u003c\/td\u003e\n\u003ctd\u003eGrounding bar set screws 25 in-lbs; lid screw 50 in-lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003e10 years for electrical junction boxes, from shipment (IronRidge limited warranty and JayBox page)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eIronRidge JayBox Installation Manual, Version 1.6 (2025); IronRidge JayBox Cut Sheet, Roof Mount, Rev 1.10 (2024); IronRidge JayBox page, ironridge.com, retrieved Oct 8, 2026; IronRidge Parts Catalog, Version 3.66 (2026); IronRidge Limited Warranties and Disclaimer (Warranty.IronRidge.2025)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA comp shingle roof in good condition\u003c\/strong\u003e within IronRidge's slope range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductors and listed wire connectors:\u003c\/strong\u003e Sized within IronRidge's allowable wire ranges and the NEC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRail mounting instead:\u003c\/strong\u003e See the \u003ca href=\"\/products\/quick-mount-pv-jaybox-junction-box-rail-mount-qm-jbx-rl02-b1\"\u003eJayBox rail mount (QM-JBX-RL02-B1)\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit flashing:\u003c\/strong\u003e See the \u003ca href=\"\/products\/ironridge-conduit-penetration-flashing-mill-qmcpc-a-12\"\u003eIronRidge Conduit Penetration Flashing\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther junction boxes and conduit mounts:\u003c\/strong\u003e See \u003ca href=\"\/collections\/junction-boxes-and-conduit-mounts\"\u003ejunction boxes \u0026amp; conduit mounts\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAttic pass-through.\u003c\/strong\u003e IronRidge says not to install attic pass-through holes without the flashing and self-drilling roofing screws, and not to install the box directly over a rafter when using the pass-through.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlacement.\u003c\/strong\u003e IronRidge says to avoid keyways, shingle joints or tabs in the shingle course above the box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding.\u003c\/strong\u003e The box itself needs no grounding, per IronRidge. Equipment grounding conductors still land on the ground bar as the NEC requires.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLicensed work.\u003c\/strong\u003e Install to the NEC edition your AHJ has adopted and the maker's current installation instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Quick Mount PV","offers":[{"title":"Default Title","offer_id":46279653621979,"sku":"QM-JBX-RF02-B1","price":72.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/ironridge-JayBox_Roof_Mount_Hero.jpg?v=1791406011","url":"https:\/\/www.altestore.com\/products\/quick-mount-pv-jaybox-junction-box-comp-shingle-roof-mount-qm-jbx-rf02-b1","provider":"AltE Store","version":"1.0","type":"link"}