{"product_id":"ironridge-quickmount-lynx-standing-seam-metal-roof-clamp-qm-lynx-ss-m1","title":"IronRidge QuickMount Lynx Standing Seam Metal Roof Clamp – QM-LYNX-SS-M1","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eIronRidge QuickMount Lynx (QM-LYNX-SS-M1) is a non-penetrating clamp for standing seam metal roofs. IronRidge designed it for use with IronRidge open-slotted L-Feet and IronRidge rails. The technology is licensed by S-5!.\u003c\/p\u003e\n\u003cp\u003eTwo pre-assembled oval-point set screws clamp the seam. IronRidge says the oval points allow adjustment and reseating without damaging the roofing, and no roof penetrations are required.\u003c\/p\u003e\n\u003cp\u003eAn open-ended T-slot on top gives about 2\" of north-south adjustment for sliding the L-foot into line with the rail. The included hex bolt and serrated flange nut secure the L-foot, which is sold separately.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStanding seam roofs with seams at least 1.0\" tall:\u003c\/strong\u003e IronRidge says Lynx fits folding and snapping standing seams. The seam must be at least 1.0\" tall and no more than 0.5\" wide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIronRidge XR Flush Mount systems:\u003c\/strong\u003e Lynx is listed as a metal roof attachment in IronRidge's XR Flush Mount manual. Pair it with the \u003ca href=\"\/products\/ironridge-slotted-l-foot-mill-lft-03-m1\"\u003eIronRidge Slotted L-Foot (mill)\u003c\/a\u003e or \u003ca href=\"\/products\/ironridge-slotted-l-foot-black-lft-03-b1\"\u003eblack\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoofs that should not be penetrated:\u003c\/strong\u003e The set screws grip the seam without piercing the panel, per IronRidge.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eNon-penetrating standing seam metal roof clamp, IronRidge QuickMount product line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eQM-LYNX-SS-M1 (Lynx Standing Seam Metal Clamp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded (per IronRidge cut sheet)\u003c\/td\u003e\n\u003ctd\u003e1 Lynx block, 6000 series aluminum, mill; 2 hex drive set screws, 3\/8-24, 300 series stainless steel; 1 hex bolt, 5\/16-18 × 1\", 300 series stainless steel; 1 serrated flange lock nut\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNot included\u003c\/td\u003e\n\u003ctd\u003eL-foot (shown for reference on the cut sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible seams (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eFolding and snapping standing seams; vertical seam height at least 1.0\"; horizontal seam width 0.5\" maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustment\u003c\/td\u003e\n\u003ctd\u003eAbout 2\" north-south in the open-ended T-slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eCertified component tested and evaluated to conform with UL 2703; part of the UL 2703 listed XR Flush Mount system. Certification includes bonding to painted and Galvalume metal roofs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign support (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eIncluded in IronRidge's Pitched Roof Design Assistant, with a stamped certification letter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003e25-year warranty period for products. See IronRidge Limited Warranties and Disclaimer (Warranty.IronRidge.2025) for terms and exclusions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eIronRidge QuickMount Lynx Cut Sheet QM-LYNX-SS-M1 Rev 1.01; IronRidge Lynx Installation Manual Version 1.0 (2025); IronRidge QuickMount Lynx Tech Brief (2023); IronRidge XR Flush Mount Installation Manual, Version 5.2 (2026); IronRidge XR Flush Mount System Datasheet, Version 2.10 (2026); IronRidge Limited Warranties and Disclaimer (Warranty.IronRidge.2025)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAn IronRidge Slotted L-Foot:\u003c\/strong\u003e Sold separately. See \u003ca href=\"\/products\/ironridge-slotted-l-foot-mill-lft-03-m1\"\u003emill\u003c\/a\u003e or \u003ca href=\"\/products\/ironridge-slotted-l-foot-black-lft-03-b1\"\u003eblack\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIronRidge XR rails and bonding hardware:\u003c\/strong\u003e IronRidge says to secure compatible rails to each L-foot with the racking manufacturer's approved bonding hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAn impact driver with a 3\/16\" hex bit and a 1\/2\" socket:\u003c\/strong\u003e Listed in IronRidge's Lynx and XR Flush Mount manuals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA string line:\u003c\/strong\u003e IronRidge suggests running one between the outermost attachments to keep the clamps and rail straight.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule clamps and grounding:\u003c\/strong\u003e See \u003ca href=\"\/collections\/roof-mounts-for-solar-panels\"\u003eroof mounts\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther metal roof attachments:\u003c\/strong\u003e For exposed-fastened or corrugated roofs, see \u003ca href=\"\/collections\/metal-roof-mounts\"\u003emetal roof mounts\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the seam before ordering.\u003c\/strong\u003e IronRidge's Lynx manual shows compatible and incompatible profiles. Seams under 1.0\" tall or wider than 0.5\" are outside its stated range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeat the block fully.\u003c\/strong\u003e IronRidge says to make sure the block is fully seated on the seam, then torque the set screws, alternating between them.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther racking needs engineering.\u003c\/strong\u003e IronRidge says Lynx can support other racking platforms only with additional engineering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineering and permits.\u003c\/strong\u003e Attachment spacing, rafter or deck requirements and load capacity are project-specific. Use IronRidge's design tools and stamped certification letters, and install under local building codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"IronRidge","offers":[{"title":"Default Title","offer_id":46459532968155,"sku":"QM-LYNX-SS-M1","price":10.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/Lynx_1.jpg?v=1738285543","url":"https:\/\/www.altestore.com\/products\/ironridge-quickmount-lynx-standing-seam-metal-roof-clamp-qm-lynx-ss-m1","provider":"AltE Store","version":"1.0","type":"link"}