{"product_id":"ironridge-flashfoot2-flashed-comp-shingle-roof-attachment-mill-ff2-02-m2","title":"IronRidge FlashFoot2 Flashed Comp Shingle Roof Attachment, Mill – FF2-02-M2","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eIronRidge FlashFoot2 (FF2-02-M2) is a flashed roof attachment for composition (asphalt) shingle roofs. This listing is the mill finish. It anchors IronRidge XR rails to the roof rafters.\u003c\/p\u003e\n\u003cp\u003eThe aluminum flashing slides under the shingle course. A stainless steel lag bolt with an EPDM-backed washer goes through the flashing into the rafter. A twist-on Cap then locks over the bolt and gives the rail an open slot to attach to.\u003c\/p\u003e\n\u003cp\u003eIronRidge describes a three-tier water seal: an elevated platform that diverts water, a stack of components that raises the seal an inch, and a Cap that encapsulates the seal. IronRidge says the Cap aligns the rail with the lag bolt in a concentric load path.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComposition shingle roofs:\u003c\/strong\u003e IronRidge rates FlashFoot2's water seal for composition shingle roofs with slopes between 2:12 and 12:12.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIronRidge XR Flush Mount systems:\u003c\/strong\u003e IronRidge's FlashFoot2 manual says it is ready for IronRidge XR Rails once installed. The Cap can face E\/W or N\/S rails.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalls that use one socket size:\u003c\/strong\u003e IronRidge says the custom lag bolt uses the same 7\/16\" socket as other Flush Mount components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMill racking:\u003c\/strong\u003e Choose this finish to match mill rails and clamps. The black version is sold separately.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eFlashed composition shingle roof attachment, IronRidge XR Flush Mount system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eFF2-02-M2 (FlashFoot2, mill)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIncluded per kit (per IronRidge cut sheet)\u003c\/td\u003e\n\u003ctd\u003e1 lag bolt, 5\/16\" × 4.25\", 300 series stainless steel; 1 flashing assembly, aluminum; 1 Cap assembly, aluminum; 1 EPDM-backed washer, 300 series stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlashing size\u003c\/td\u003e\n\u003ctd\u003e8.0 × 12.0 in (cut sheet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eMill (flashing and Cap); lag bolt and washer clear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoof type\u003c\/td\u003e\n\u003ctd\u003eComposition shingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater seal testing (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eTested to UL 441 Section 27 \"Rain Test\" and TAS 100-95 \"Wind Driven Rain Test\" by Intertek; ratings apply to composition shingle roofs with slopes between 2:12 and 12:12; tested and evaluated without sealant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStructural certification (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eDesigned and certified for compliance with the International Building Code and ASCE\/SEI-7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL 2703 (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eConforms to UL 2703 mechanical and bonding requirements; IronRidge refers to the XR Flush Mount Installation Manual for full ratings. The XR Flush Mount system is UL 2703 listed (manual Version 5.2).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRail orientation\u003c\/td\u003e\n\u003ctd\u003eE\/W or N\/S; rail can be installed on either side of the Cap\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003e25-year warranty period for products; 5-year finish warranty, which IronRidge says does not apply to mill aluminum. See IronRidge Limited Warranties and Disclaimer (Warranty.IronRidge.2025) for terms and exclusions.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eIronRidge FlashFoot2 Cut Sheet v2.10; IronRidge FlashFoot2 Installation Manual FM-FF2-MAN Rev 1.21; IronRidge FlashFoot2 Tech Brief Version 1.01; IronRidge XR Flush Mount Installation Manual, Version 5.2 (2026); IronRidge Limited Warranties and Disclaimer (Warranty.IronRidge.2025)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIronRidge XR rails and bonding hardware:\u003c\/strong\u003e The rail attaches to either side of the Cap's open slot with IronRidge bonding hardware (sold separately).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoofing sealant for the pilot holes:\u003c\/strong\u003e IronRidge's steps say to fill each 1\/4\" pilot hole with the roofing manufacturer's approved sealant.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule clamps and grounding:\u003c\/strong\u003e Choose them from IronRidge's XR Flush Mount manual for your modules. See \u003ca href=\"\/collections\/roof-mounts-for-solar-panels\"\u003eroof mounts\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSplices and expansion joints:\u003c\/strong\u003e IronRidge requires expansion joints on rows of continuous rail over 100 feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTools:\u003c\/strong\u003e IronRidge lists a tape measure, chalk line, stud finder, roofing bar, caulking gun, and a driver with a 1\/4\" bit and 7\/16\" hex socket.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther roof types on the same project:\u003c\/strong\u003e For tile, metal or low-slope sections, see IronRidge's manual for its other attachments, and browse \u003ca href=\"\/collections\/solar-panel-mounts\"\u003esolar panel mounts\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlacement under the shingles.\u003c\/strong\u003e IronRidge says to slide the flashing between the 1st and 2nd courses. The top must sit at least 3\/4\" above the edge of the 3rd course, and the bottom above the edge of the 1st course.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLag into the rafter.\u003c\/strong\u003e Locate rafters, snap lines and drill 1\/4\" pilot holes as IronRidge's manual describes. Tighten the lag bolt until fully seated.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComposition shingle only.\u003c\/strong\u003e IronRidge's water seal ratings for FlashFoot2 apply to composition shingle roofs between 2:12 and 12:12 slope.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFinish warranty.\u003c\/strong\u003e IronRidge's 5-year finish warranty does not apply to mill aluminum, per its limited warranty document.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineering and permits.\u003c\/strong\u003e Attachment spacing, rafter or deck requirements and load capacity are project-specific. Use IronRidge's design tools and stamped certification letters, and install under local building codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"IronRidge","offers":[{"title":"Default Title","offer_id":46166692102363,"sku":"FF2-02-M2","price":21.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/ironridge-ff2_hero_mill.jpg?v=1791403071","url":"https:\/\/www.altestore.com\/products\/ironridge-flashfoot2-flashed-comp-shingle-roof-attachment-mill-ff2-02-m2","provider":"AltE Store","version":"1.0","type":"link"}