{"product_id":"ironridge-bx-ballasted-chassis-5-tilt-flat-roof-bx-5d-p1","title":"IronRidge BX Ballasted Chassis, 5° Tilt, Flat Roof – BX-5D-P1","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe IronRidge BX Chassis (BX-5D-P1) is a ballasted mount for flat roofs. It holds a solar module at a fixed 5° tilt, and concrete blocks placed inside it hold the array down instead of roof bolts.\u003c\/p\u003e\n\u003cp\u003eIronRidge molds the chassis from BASF Ultramid, a glass-reinforced polyamide (nylon). IronRidge says a flange around the edge stiffens it, and a wide base spreads weight to reduce point pressure on the roof.\u003c\/p\u003e\n\u003cp\u003eOpenings in the base keep water from pooling, per IronRidge. Modules attach with a BX bottom clamp and a BX top clamp at each corner. IronRidge designed BX for commercial flat-roof projects.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlat commercial roofs:\u003c\/strong\u003e IronRidge says BX is designed for the needs of commercial solar on flat roofs, including complex roof layouts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eArrays that avoid roof penetrations:\u003c\/strong\u003e A fully ballasted BX array is held by concrete blocks. IronRidge also allows anchored or hybrid layouts using its Flat Roof Attachment Kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA 5° module tilt:\u003c\/strong\u003e IronRidge makes the chassis in 5° and 10° versions. This listing is the 5° version.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eBallasted flat-roof mount (chassis), 5° tilt, IronRidge BX System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003eBX-5D-P1, \"BX Chassis, 5 Degrees\" (IronRidge Parts Catalog)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003eBASF Ultramid glass-reinforced polyamide (nylon)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBallast capacity (per IronRidge manual)\u003c\/td\u003e\n\u003ctd\u003e4 full-size (16\" × 8\" × 4\") or 8 half-size (16\" × 8\" × 2\") concrete blocks, nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBallast block requirements (per IronRidge manual)\u003c\/td\u003e\n\u003ctd\u003eASTM C 1491 pavers; freeze-thaw resistant where local conditions require; 3000 PSI minimum compressive strength; 28–34 lbs (full) or 14–17 lbs (half), ±2 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRow spacing (per IronRidge manual)\u003c\/td\u003e\n\u003ctd\u003eDepends on module width. Example: 48.5\" for modules 38.5–39\" wide. The manual gives a full table.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoof pitch (per IronRidge manual)\u003c\/td\u003e\n\u003ctd\u003eApproved for roof pitches up to 7 degrees\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule orientation (per IronRidge manual)\u003c\/td\u003e\n\u003ctd\u003eLandscape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUL listings (per IronRidge manual)\u003c\/td\u003e\n\u003ctd\u003eIronRidge's BX manual lists the BX System as UL 2703 and UL 3741 listed (#5014158, #5025960). It says the UL 2703 scope of evaluation includes bonding, grounding, mechanical loading and fire classification.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFire rating (per IronRidge manual)\u003c\/td\u003e\n\u003ctd\u003eClass A system fire rating per UL 2703 at any system tilt with module types 1, 2, 3, 13, 16, 19, 22, 25, 29, 30 and 38 on low-slope roofs (under 9.5 degrees)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty (per IronRidge)\u003c\/td\u003e\n\u003ctd\u003e25 years for products and 10 years for accessories and electrical junction boxes, from shipment. The 5-year finish warranty does not apply to mill aluminum, pre-plated steel or polymeric products. See IronRidge Limited Warranties and Disclaimer (Warranty.IronRidge.2025).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eIronRidge Parts Catalog, Version 3.66 (2026); IronRidge BX System Installation Manual, Version 4.2 (2026); IronRidge BX Ballasted System Datasheet, Version 1.30; IronRidge BX Chassis Tech Brief, Version 1.20; IronRidge Limited Warranties and Disclaimer (Warranty.IronRidge.2025)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule clamps:\u003c\/strong\u003e A \u003ca href=\"\/products\/ironridge-bx-bottom-clamp-mill-bx-bcl-m1\"\u003eBX bottom clamp\u003c\/a\u003e and a BX top clamp, such as the \u003ca href=\"\/products\/ironridge-bx-top-clamp-for-35mm-module-frames-mill-bx-tcl-35mm-m1\"\u003e35mm top clamp\u003c\/a\u003e, at each module corner.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBonding and grounding:\u003c\/strong\u003e IronRidge uses \u003ca href=\"\/products\/ironridge-bx-module-bonding-jumper-8-bx-mb8-m1\"\u003e8\" module bonding jumpers\u003c\/a\u003e between modules, 38\" row bonding jumpers between rows, and one \u003ca href=\"\/products\/ironridge-pv-module-grounding-lug-pv-lug-01-a1\"\u003ePV module grounding lug\u003c\/a\u003e per continuous array.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConcrete ballast blocks:\u003c\/strong\u003e Sourced locally, in the quantity shown on the project's ballast plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof anchors:\u003c\/strong\u003e For anchored or hybrid layouts, IronRidge uses the BX Flat Roof Mounting Assembly (BX-MA-FRA-M1) with an \u003ca href=\"\/products\/ironridge-flat-roof-attachment-mill-fra-base-01-m1\"\u003eIronRidge Flat Roof Attachment\u003c\/a\u003e and locally sourced strut.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlip sheets:\u003c\/strong\u003e IronRidge says slip-sheet needs depend on the roofing material, maker and location. Ask the roofing manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe 10° chassis:\u003c\/strong\u003e See the \u003ca href=\"\/products\/ironridge-bx-ballasted-chassis-10-tilt-flat-roof-bx-10d-p1\"\u003eBX 10° chassis\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamp placement.\u003c\/strong\u003e IronRidge's manual says clamps go on all four corner bolt positions that hold a module. The north end of the north row and the south end of the south row do not need clamps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBallast plan.\u003c\/strong\u003e IronRidge's Design Assistant creates a ballast map showing the blocks needed in each chassis. Do not guess block counts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnchor locations.\u003c\/strong\u003e IronRidge's manual says anchors shall not be placed on a perimeter south row.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling.\u003c\/strong\u003e IronRidge says to always wear gloves when handling BX chassis.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUL 3741 projects.\u003c\/strong\u003e IronRidge's UL 3741 listing applies with the equipment and steps in its BX UL 3741 Installation Addendum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof slope.\u003c\/strong\u003e IronRidge's BX manual says BX is approved for roof pitches up to 7 degrees. It also says to make sure the roof is in good condition before installing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck your module.\u003c\/strong\u003e IronRidge's BX manual lists the modules tested or evaluated with BX, by maker, model and frame height. BX modules are installed in landscape orientation, per the manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEngineering and permits.\u003c\/strong\u003e IronRidge says actual structural capacities are defined by PE-stamped certification letters. Use IronRidge's Design Assistant for the layout and ballast plan, and install under local codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"IronRidge","offers":[{"title":"Default Title","offer_id":46166694887643,"sku":"BX-5D-P1","price":57.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/ironridge-bx-chassis_5deg.jpg?v=1791403087","url":"https:\/\/www.altestore.com\/products\/ironridge-bx-ballasted-chassis-5-tilt-flat-roof-bx-5d-p1","provider":"AltE Store","version":"1.0","type":"link"}