{"product_id":"enphase-iq8ac-microinverter-240v-208v-366va-peak-iq8ac-72-m-us","title":"Enphase IQ8AC Microinverter, 240V\/208V, 366VA Peak – IQ8AC-72-M-US","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Enphase IQ8AC is a microinverter: a small inverter that mounts under one solar panel and turns that panel's DC (direct current) electricity into AC (alternating current) electricity, the kind your home and the utility grid use. Each solar panel gets its own IQ8AC.\u003c\/p\u003e\n\u003cp\u003eIt is rated for 349 VA of continuous output (366 VA peak) on a 240 V split-phase home service, the standard setup in most U.S. houses. It can also connect to 208 V single-phase service at slightly lower output. Enphase lists commonly used panel pairings of 295 to 500 watts.\u003c\/p\u003e\n\u003cp\u003eThe IQ8AC is part of the Enphase Energy System. Microinverters on a circuit connect to one Enphase IQ Cable, and they report to an Enphase IQ Gateway over the home's power wiring (power line communication). When the system is installed with an Enphase IQ System Controller 2 or 3, Enphase says IQ8 microinverters can keep producing power during a grid outage.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrid-tied home solar:\u003c\/strong\u003e Converts solar power for use in the home and for sending extra power back to the utility. Ships with settings that meet the IEEE 1547 grid-connection standard, and the installer can change grid settings through an IQ Gateway.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoofs with panels facing different directions or with some shade:\u003c\/strong\u003e Each panel has its own microinverter with its own MPPT (Maximum Power Point Tracking, which keeps each panel working at the voltage that produces the most power), so panels aren't wired together in one long high-voltage DC string.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSolar with battery backup:\u003c\/strong\u003e As part of a full Enphase system with an IQ System Controller 2 or 3 and Enphase IQ Batteries, the solar array can keep producing power while the grid is down.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuildings with 208 V service:\u003c\/strong\u003e Rated for 208 V single-phase (line-to-line) connections, with 345 VA continuous output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eMicroinverter (one per solar panel), Enphase IQ8 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer part number\u003c\/td\u003e\n\u003ctd\u003eIQ8AC-72-M-US\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak output power\u003c\/td\u003e\n\u003ctd\u003e366 VA at 240 V \/ 350 VA at 208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous output power\u003c\/td\u003e\n\u003ctd\u003e349 VA at 240 V \/ 345 VA at 208 V. This is the output the microinverter can sustain continuously.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid connection\u003c\/td\u003e\n\u003ctd\u003e240 V split-phase (L-L) or 208 V single-phase (L-L), 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous output current\u003c\/td\u003e\n\u003ctd\u003e1.45 A at 240 V \/ 1.66 A at 208 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum units per 20 A branch circuit\u003c\/td\u003e\n\u003ctd\u003e11 at 240 V \/ 9 at 208 V. This limits how many panels can share one circuit. Local rules may set a lower limit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommonly used panel pairings\u003c\/td\u003e\n\u003ctd\u003e295–500 W panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMPPT voltage range\u003c\/td\u003e\n\u003ctd\u003e28–45 V. The panel's working voltage should fall in this range for full output.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating range; start voltage\u003c\/td\u003e\n\u003ctd\u003e18–58 V; 22 V minimum \/ 58 V maximum start voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum input DC voltage\u003c\/td\u003e\n\u003ctd\u003e60 V. The panel's voltage must never go above this, including on cold mornings.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous input DC current\u003c\/td\u003e\n\u003ctd\u003e14 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum module Isc\u003c\/td\u003e\n\u003ctd\u003e20 A (the panel's short-circuit current must be at or below this)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCEC weighted efficiency\u003c\/td\u003e\n\u003ctd\u003e97.0% at 240 V \/ 96.5% at 208 V. On average, about 97% of the panel's DC power comes out as usable AC power.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003eStäubli MC4 DC connectors (panel side); Enphase AC connector (IQ Cable side)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003ePower line communication (PLC) to an Enphase IQ Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRapid shutdown\u003c\/td\u003e\n\u003ctd\u003eUL Listed as PV rapid shutdown equipment; conforms with NEC 2014, 2017, 2020 and 2023 section 690.12 when installed according to Enphase's instructions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid standards\u003c\/td\u003e\n\u003ctd\u003eCA Rule 21 (UL 1741-SA), IEEE 1547:2018 (UL 1741-SB 3rd Ed.), UL 62109-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 6, outdoor; Class II double-insulated polymer enclosure; approved for wet locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eNatural convection, no fans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient temperature range\u003c\/td\u003e\n\u003ctd\u003e−40°F to 149°F (−40°C to 65°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions and weight\u003c\/td\u003e\n\u003ctd\u003e8.3 × 6.9 × 1.2 in (212 × 175 × 30.2 mm); 2.43 lb (1.1 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003eLimited warranty of up to 25 years (see Enphase warranty terms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/solar-panels\"\u003eSolar panels\u003c\/a\u003e:\u003c\/strong\u003e One panel per microinverter. Check that the panel's voltage and current fit the IQ8AC limits using Enphase's module compatibility calculator before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnphase IQ Cable and cable accessories:\u003c\/strong\u003e The IQ8AC's AC side uses an Enphase AC connector, and microinverters on a circuit connect to one Enphase IQ Cable. Enphase sells IQ Cable with different connector spacings, such as \u003ca href=\"\/products\/enphase-iq-cable-single-connection-12-awg-1-3-m-4-2-ft-connector-spacing-q-12-10-240\"\u003eQ-12-10-240\u003c\/a\u003e (1.3 m), \u003ca href=\"\/products\/enphase-iq-cable-single-connection-12-awg-2-0-m-6-5-ft-connector-spacing-q-12-17-240\"\u003eQ-12-17-240\u003c\/a\u003e (2.0 m) and \u003ca href=\"\/products\/enphase-iq-cable-single-connection-12-awg-2-3-m-7-5-ft-connector-spacing-q-12-20-200\"\u003eQ-12-20-200\u003c\/a\u003e (2.3 m); choose the spacing that fits your panel layout. Enphase's IQ Cable data sheet also lists an \u003ca href=\"\/products\/enphase-iq-terminator-cap-for-cable-ends-q-term-10\"\u003eIQ Terminator (Q-TERM-10)\u003c\/a\u003e for unused cable ends and \u003ca href=\"\/products\/enphase-iq-sealing-cap-female-q-seal-10\"\u003eIQ Sealing Caps (Q-SEAL-10)\u003c\/a\u003e, one for each unused connector on the cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/enphase-iq-gateway-formerly-iq-envoy-metered-env2-iq-am1-240\"\u003eIQ Gateway (ENV2-IQ-AM1-240)\u003c\/a\u003e or an \u003ca href=\"\/collections\/combiner-boxes\"\u003eIQ Combiner\u003c\/a\u003e with a built-in gateway:\u003c\/strong\u003e Enphase uses the IQ Gateway to set grid settings during installation and to give the system monitoring and an internet connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/roof-mounts-for-solar-panels\"\u003eSolar mounting hardware\u003c\/a\u003e:\u003c\/strong\u003e Rails, roof attachments and clamps to hold the panels. Follow your racking manufacturer's instructions for where and how to mount the microinverters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/disconnects-breakers\"\u003eBreakers and AC disconnects\u003c\/a\u003e:\u003c\/strong\u003e Enphase requires AC-side protection of no more than 20 A per branch circuit. Your local code or utility may also require an AC disconnect.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnphase IQ Battery (such as the \u003ca href=\"\/products\/enphase-iq-battery-5p-5kwh-ac-coupled-lfp-battery-iqbattery-5p-1p-na\"\u003eIQ Battery 5P\u003c\/a\u003e) and \u003ca href=\"\/products\/enphase-iq-system-controller-3-200a-sc200d111c240us01\"\u003eIQ System Controller 3\u003c\/a\u003e:\u003c\/strong\u003e Needed if you want backup power. Enphase says the IQ8AC can produce power during an outage only when the system is installed with an IQ System Controller 2 or 3. Enphase now lists the IQ System Controller 2 as end-of-life, so choose the IQ System Controller 3 for new purchases (or the \u003ca href=\"\/products\/enphase-iq-system-controller-3g-200a-with-generator-support-sc200g111c240us01\"\u003eIQ System Controller 3G\u003c\/a\u003e, which adds generator support).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck panel fit first.\u003c\/strong\u003e The panel must stay at or under 60 V DC and 20 A short-circuit current. A panel's voltage rises in cold weather, so check it at your site's lowest expected temperature. Enphase's module compatibility calculator is the reference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBranch circuit limits.\u003c\/strong\u003e Up to 11 IQ8AC units fit on a 20 A circuit at 240 V, or 9 at 208 V. Local requirements may lower that number.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup is not automatic.\u003c\/strong\u003e Enphase says the IQ8AC can produce power during a grid outage only when it is installed with an IQ System Controller 2 or 3. Plan for that equipment if backup matters to you.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixing with older IQ7 microinverters.\u003c\/strong\u003e IQ8 units can be added to some existing IQ7 systems under Enphase's rules, but IQ7 units cannot be added to a site that already has IQ8 units on the same gateway. Mixed systems lose some IQ8-only features.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrid settings.\u003c\/strong\u003e The microinverter ships with IEEE 1547 default settings. Your utility or local inspector may require different settings, which the installer sets through an IQ Gateway.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation.\u003c\/strong\u003e The rapid shutdown listing applies only when the system is installed according to Enphase's instructions. Follow local electrical code and your utility's interconnection rules.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Enphase Energy","offers":[{"title":"Default Title","offer_id":46166688334043,"sku":"IQ8AC-72-M-US","price":227.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/enphase-iq8ac-IQ8AC_US_Hero.png?v=1791401703","url":"https:\/\/www.altestore.com\/products\/enphase-iq8ac-microinverter-240v-208v-366va-peak-iq8ac-72-m-us","provider":"AltE Store","version":"1.0","type":"link"}