{"product_id":"enphase-iq-meter-collar-200a-meter-socket-backup-adapter-mc-200-011-v01","title":"Enphase IQ Meter Collar, 200A Meter-Socket Backup Adapter – MC-200-011-V01","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Enphase IQ Meter Collar (model MC-200-011-V01) is a meter-socket adapter with a built-in microgrid interconnection device (MID) and energy meter. It installs between the utility meter and an ANSI Form 2S meter socket, or on a separate meter socket on the load side of the service, and is rated for 200 A continuous current.\u003c\/p\u003e\n\u003cp\u003eIn an Enphase Energy System with batteries, the MID is the switch that disconnects the home from the grid during an outage so the Enphase system can power it, then reconnects when the grid returns. Enphase says installing it at the meter lowers the cost of whole-home backup.\u003c\/p\u003e\n\u003cp\u003eEnphase lists the meter collar for use with specific Enphase equipment (see the table). Enphase lists third-party inverter support with the 4th-generation Enphase Energy System.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnphase whole-home backup:\u003c\/strong\u003e Enphase's datasheet lists it with the IQ Battery 10C\/10CS and IQ Combiner 6C (4th-generation system), and with IQ Battery 5P, IQ Combiner 5\/5C and IQ System Controller 3M (3rd-generation system).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e120\/240 V split-phase homes with a 200 A Form 2S meter socket:\u003c\/strong\u003e Ring or ringless sockets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eMeter-socket adapter with integrated microgrid interconnection device (MID) and consumption meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel; ordering SKUs\u003c\/td\u003e\n\u003ctd\u003eMC-200-011-V01 (Enphase also lists ordering SKU MC-200-011-V01-2). Enphase says to use the model number for interconnection applications and permitting.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrid supply\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC, 180°, split-phase; 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous current\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum short-circuit current withstand\u003c\/td\u003e\n\u003ctd\u003e22 kA (limited by an external overcurrent protection device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum overcurrent protection device\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeter and socket interface\u003c\/td\u003e\n\u003ctd\u003eANSI Form 2S, 200 A, ringless or ring type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated consumption meter\u003c\/td\u003e\n\u003ctd\u003e±0.5% accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eCategory IV (service entrance-rated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e3.8 W nominal (2.5–5.8 W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnphase equipment compatibility (per Enphase)\u003c\/td\u003e\n\u003ctd\u003eGateway ENV2-IQ-AM1-240 and ENV-IQ-AM1-240; COMMS-KIT-02; IQ8, IQ7 and IQ6 Series microinverters. 4th generation: IQ Battery 10C (IQBATTERY-10C-1P-NA), IQ Battery 10CS and IQ Combiner 6C (X-IQ-AM1-240-6C). 3rd generation: IQ Battery 5P (IQBATTERY-5P-1P-NA), IQ Combiner 5\/5C and IQ System Controller 3M (SC200D111CMC1US01).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThird-party inverters and legacy Enphase microinverters\u003c\/td\u003e\n\u003ctd\u003eSupported with the 4th-generation Enphase Energy System, per Enphase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003e4-wire control connector (24 VDC); manual override lever; push button; status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIn the box\u003c\/td\u003e\n\u003ctd\u003eMeter collar, seal ring, plastic hanging bag, quick install guide, accessories kit (control connector, junction box sub-assembly, 1\/2 in NPT cable gland), blank cover plate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure; temperature\u003c\/td\u003e\n\u003ctd\u003eIndoor\/outdoor, NEMA Type 3R; −40°C to 50°C (−40°F to 122°F); forced-convection cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum altitude\u003c\/td\u003e\n\u003ctd\u003e2,500 m (8,200 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions; weight\u003c\/td\u003e\n\u003ctd\u003e175 × 206 × 128 mm (6.9 × 8.1 × 5.0 in); 1.63 kg (3.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompliance (per Enphase)\u003c\/td\u003e\n\u003ctd\u003eUL 414, CSA C22.2 No. 115:2025; CFR 47 Part 15B; UL 1741 SA\/SB (IEEE 1547:2018); current sensor for a power control system under UL 3141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty (per Enphase)\u003c\/td\u003e\n\u003ctd\u003e15-year limited warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eEnphase IQ Meter Collar datasheet DSH-00468-7.0-EN-2026-04-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnphase battery and controller equipment from the compatibility list:\u003c\/strong\u003e For example, the \u003ca href=\"\/products\/enphase-iq-battery-10c-10kwh-ac-coupled-lfp-battery-iqbattery-10c-1p-na\"\u003eIQ Battery 10C\u003c\/a\u003e with the \u003ca href=\"\/products\/enphase-iq-combiner-6c-x-iq-am1-240-6c\"\u003eIQ Combiner 6C\u003c\/a\u003e, or the \u003ca href=\"\/products\/enphase-iq-battery-5p-5kwh-ac-coupled-lfp-battery-iqbattery-5p-1p-na\"\u003eIQ Battery 5P\u003c\/a\u003e with IQ Combiner 5\/5C and IQ System Controller 3M.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl cable:\u003c\/strong\u003e 4-wire signaling between the collar and the Enphase system. Enphase lists an 18\/4 TC-ER control cable spool (CTRL-SC3-NA-01) as an accessory.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility approval:\u003c\/strong\u003e The collar installs at the utility meter, so the utility must allow it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnphase accessory kits:\u003c\/strong\u003e A replacement junction box assembly (ACC-MC-200 for MC-200-011-V01), a jumper cover (JC-MC-200) or a 200 A ringless meter socket (MP-MC-200) for load-side installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA separate meter socket:\u003c\/strong\u003e Needed if the collar is installed on the load side rather than at the utility meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/enphase-iq-gateway-formerly-iq-envoy-metered-env2-iq-am1-240\"\u003eEnphase IQ Gateway, Metered (ENV2-IQ-AM1-240)\u003c\/a\u003e:\u003c\/strong\u003e Listed by Enphase as a compatible gateway, for systems that do not already have one.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the system generation.\u003c\/strong\u003e Enphase lists IQ System Controller 3M (SC200D111CMC1US01) for 3rd-generation systems. Other IQ System Controller models are not on this datasheet's list, so confirm your controller model with Enphase before ordering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm 2S, 200 A only.\u003c\/strong\u003e The collar fits ANSI Form 2S, 200 A meter sockets on 120\/240 V split-phase service. It is not for three-phase or higher-ampacity services.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUtility rules.\u003c\/strong\u003e Some utilities do not allow meter collars or require their own approval and inspection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfessional installation.\u003c\/strong\u003e Installing at the meter requires utility coordination and a qualified electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Enphase Energy","offers":[{"title":"Default Title","offer_id":47303174455515,"sku":"MC-200-011-V01","price":698.74,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/1_3.avif?v=1753388454","url":"https:\/\/www.altestore.com\/products\/enphase-iq-meter-collar-200a-meter-socket-backup-adapter-mc-200-011-v01","provider":"AltE Store","version":"1.0","type":"link"}