{"product_id":"briggs-stratton-simpliphi-6-6-lithium-battery-controller-1-per-stack-053084","title":"Briggs \u0026 Stratton SimpliPHI 6.6 Lithium Battery Controller, 1 per Stack – 053084","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Briggs \u0026amp; Stratton SimpliPHI 6.6 Battery Controller (part 053084) is the control unit that sits on top of every stack of SimpliPHI 6.6 battery modules. Briggs \u0026amp; Stratton requires one controller per stack of one to three modules. The stack can't be used without it.\u003c\/p\u003e\n\u003cp\u003eThe controller is where the stack connects to the rest of the system. It has the stack's DC power terminals for the battery cables, the power button that turns the stack on and off, status lights, and two communication ports (one labeled CAN and one labeled RS485). Through those ports the battery can \"talk\" to a supported inverter or to Briggs \u0026amp; Stratton's EnergyTrak monitoring gateway. Briggs \u0026amp; Stratton says communication is not required for the battery system to work, but it enables extra functions.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvery new SimpliPHI 6.6 stack:\u003c\/strong\u003e Each stack of one, two or three 6.6 modules needs its own controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdding a stack to a growing system:\u003c\/strong\u003e Order one controller for each added stack, up to six controllers per system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystems with a communicating inverter:\u003c\/strong\u003e Briggs \u0026amp; Stratton lists full integration with EG4, Growatt, Megarevo, Solis and Sol-Ark inverters over CAN bus or RS-485. Check Briggs \u0026amp; Stratton's integration guide for your inverter model.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor installs:\u003c\/strong\u003e The controller is rated IP65 when installed as the manual describes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eStack controller for the SimpliPHI 6.6 battery system (top-of-stack power and communications unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number\u003c\/td\u003e\n\u003ctd\u003e053084 (Briggs \u0026amp; Stratton ordering number used on this listing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity needed\u003c\/td\u003e\n\u003ctd\u003e1 per stack (up to 3 batteries per stack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum per system\u003c\/td\u003e\n\u003ctd\u003e6 controllers (6 stacks, 18 batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter communication\u003c\/td\u003e\n\u003ctd\u003eCAN bus and RS-485. Full integration listed for EG4, Growatt, Megarevo, Solis and Sol-Ark; non-communicating use with any 48 V lithium-supporting inverter.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergyTrak gateway communication\u003c\/td\u003e\n\u003ctd\u003eCAN bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−4°F to 131°F (−20°C to 55°C); 0–95% relative humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePowder-coated steel; IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth × depth\u003c\/td\u003e\n\u003ctd\u003e28.6 × 6.7 in, the same footprint as a 6.6 battery module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight and weight\u003c\/td\u003e\n\u003ctd\u003eBriggs \u0026amp; Stratton makes single-access (6 in tall, 14 lb) and dual-access (8.27 in tall, 24 lb) versions of the controller.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduit entry\u003c\/td\u003e\n\u003ctd\u003eSide plate(s); up to 2 in trade-size conduit. Using the top plate for conduit or wiring voids the IP65 rating.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude\u003c\/td\u003e\n\u003ctd\u003eUp to 3,000 m (9,842 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/briggs-stratton-simpliphi-6-6kwh-lithium-battery-system-48v-up-to-three-per-stack\"\u003eSimpliPHI 6.6 battery modules\u003c\/a\u003e:\u003c\/strong\u003e One to three modules per controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase for each stack:\u003c\/strong\u003e Each stack needs a Briggs \u0026amp; Stratton floor or wall base. The \u003ca href=\"\/products\/briggs-stratton-simpliphi-floor-mount-for-6-6-lithium-battery-system\"\u003eSimpliPHI Floor Mount for 6.6\u003c\/a\u003e is for floor installs in non-seismic zones only.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery cables:\u003c\/strong\u003e The battery manual lists red and black 4\/0 AWG cables (sized to code) and 3\/8 in closed-end power lugs as required parts that are not included. AltE carries \u003ca href=\"\/products\/4-0-awg-red-battery-cable-with-red-heatshrink-96-3-8-lug-1\"\u003ered\u003c\/a\u003e and \u003ca href=\"\/products\/4-0-awg-black-battery-cable-with-black-heatshrink-96-3-8-lug\"\u003eblack\u003c\/a\u003e 4\/0 AWG cables with 3\/8 in lugs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow-voltage (48 V-class) battery inverter or hybrid inverter:\u003c\/strong\u003e The controller connects the stack to the inverter. Pick an inverter from Briggs \u0026amp; Stratton's integration list if you want closed-loop communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/disconnects-breakers\"\u003eBattery disconnect\u003c\/a\u003e:\u003c\/strong\u003e The manual calls for a disconnect between the stack and the charging equipment unless that equipment has one built in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/cable-wiring\"\u003eConduit fittings and communication cable\u003c\/a\u003e:\u003c\/strong\u003e Use a properly rated conduit fitting on the side plate, and CAT5 (or better) cable for communication wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/briggs-stratton-simpliphi-energytrak-control-system-for-lithium-batteries\"\u003eEnergyTrak monitoring\u003c\/a\u003e:\u003c\/strong\u003e The manual describes connecting the controller to an EnergyTrak gateway for battery monitoring in the EnergyTrak app.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOne per stack, no exceptions.\u003c\/strong\u003e Each stack must have a Briggs \u0026amp; Stratton controller on top and a Briggs \u0026amp; Stratton base on the bottom.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem limits.\u003c\/strong\u003e Do not go over 6 controllers or 18 battery modules per system. With dual-access controllers, no more than two controllers can be wired together. Going past these limits may damage the batteries and voids the warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep the IP65 rating.\u003c\/strong\u003e Bring conduit in through the side plate only. Using the top plate for wiring voids the outdoor rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication is optional, but limited to approved equipment.\u003c\/strong\u003e The manual says communication only works with the Briggs \u0026amp; Stratton EnergyTrak gateway and inverters Briggs \u0026amp; Stratton has approved. Follow Briggs \u0026amp; Stratton's integration guide for your inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation.\u003c\/strong\u003e Install per the NEC, NFPA 855 and local codes, following the SimpliPHI 6.6 operator's manual.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":46793525756123,"sku":"053084","price":838.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/simpliphi_6.6_battery_controller.jpg?v=1747345057","url":"https:\/\/www.altestore.com\/products\/briggs-stratton-simpliphi-6-6-lithium-battery-controller-1-per-stack-053084","provider":"AltE Store","version":"1.0","type":"link"}