{"product_id":"briggs-stratton-phi-3-8-m-3-87kwh-48v-lfp-battery","title":"Briggs \u0026 Stratton PHI 3.8-M 3.87kWh 48V LFP Battery","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Briggs \u0026amp; Stratton PHI 3.8-M (model PHI-3.8-48-M) is a 48-volt lithium battery that stores electricity for later use. It holds 3.87 kWh of energy, which is roughly what it takes to run a 1,000-watt load for close to four hours using the full 100% depth of discharge (before inverter losses). It is a building block: you can connect more of the same 48 V batteries side by side (in parallel) to store more energy.\u003c\/p\u003e\n\u003cp\u003eThe battery uses lithium iron phosphate (LFP) chemistry, which contains no cobalt. Briggs \u0026amp; Stratton says this lowers the risk of thermal runaway (a battery overheating out of control) and fire spreading. Inside is a battery management system (BMS) that protects the cells. On the outside is a 100 A DC breaker that works as an on\/off switch and as overcurrent protection (earlier production used an 80 A breaker).\u003c\/p\u003e\n\u003cp\u003eThe PHI 3.8-M doesn't make AC power on its own. It connects to a 48 V battery inverter or inverter\/charger, and that inverter powers your home or equipment. Solar panels, the grid or a generator can recharge it through properly set-up charging equipment.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-grid homes and cabins:\u003c\/strong\u003e Store daytime solar power for use at night where utility power isn't available. Briggs \u0026amp; Stratton lists the battery for on-grid and off-grid installations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHome backup:\u003c\/strong\u003e Keep critical loads running during utility outages as part of a properly designed backup system with a battery inverter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacing a lead-acid battery bank:\u003c\/strong\u003e Briggs \u0026amp; Stratton calls the PHI 3.8-M ideal for lead-acid battery replacement. Your inverter and charger settings must be changed to the PHI battery's settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaily cycling to cut electric bills:\u003c\/strong\u003e Rated for 10,000+ cycles at 80% depth of discharge, so it can be charged and used every day. Briggs \u0026amp; Stratton lists daily savings on electricity bills as a use.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall commercial systems:\u003c\/strong\u003e The manufacturer lists residential and commercial installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003e48 V lithium iron phosphate (LFP) battery module with built-in BMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer part number\u003c\/td\u003e\n\u003ctd\u003ePHI-3.8-48-M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal voltage\u003c\/td\u003e\n\u003ctd\u003e51.2 VDC (a \"48 V\" battery). It must match a 48 V inverter or charger.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC voltage range\u003c\/td\u003e\n\u003ctd\u003e48–56 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e75 Ah\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated energy\u003c\/td\u003e\n\u003ctd\u003e3.87 kWh DC at 100% depth of discharge; 3.10 kWh DC at 80% depth of discharge (Briggs \u0026amp; Stratton's product page lists 3.8 kWh at a C\/2 discharge rate). This is how much energy the battery can store. Depth of discharge (DoD) is how much of that energy you use before recharging.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum continuous charge \/ discharge\u003c\/td\u003e\n\u003ctd\u003e37.5 A DC (1.9 kW DC). This is the steady power one battery can deliver or accept. More batteries in parallel raise this limit.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum discharge (10 minutes)\u003c\/td\u003e\n\u003ctd\u003e80 A DC (4.1 kW DC), for short bursts of higher power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in protection\u003c\/td\u003e\n\u003ctd\u003eBattery management system (BMS); accessible 100 A DC breaker on\/off switch with overcurrent protection (OCPD). Earlier production used an 80 A breaker.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth of discharge\u003c\/td\u003e\n\u003ctd\u003eUp to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCycle life\u003c\/td\u003e\n\u003ctd\u003e10,000+ cycles at 80% DoD. One cycle is one full charge and discharge.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRound-trip efficiency\u003c\/td\u003e\n\u003ctd\u003e96%. About 96% of the energy you put in comes back out.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCharging temperature\u003c\/td\u003e\n\u003ctd\u003e32°F to 120°F (0°C to 49°C). Don't charge it below freezing.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003e−4°F to 140°F (−20°C to 60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage temperature\u003c\/td\u003e\n\u003ctd\u003e6 months: 14°F to 77°F (−10°C to 25°C); 3 months: −4°F to 113°F (−20°C to 45°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf-discharge\u003c\/td\u003e\n\u003ctd\u003eLess than 1% per month\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 1973, UL 1642; certified to UL 9540; UL 9540A fire safety tested; UN 3480 (shipping class for lithium-ion batteries)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminals; battery cables\u003c\/td\u003e\n\u003ctd\u003e3\/8 in (10 mm) terminals. Briggs \u0026amp; Stratton's spec sheet lists 6 AWG as the minimum battery cable; the installation manual says each battery's leads are typically 4 AWG, sized to the built-in breaker.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e13.5 × 14 × 8 in (W × H × D); 15.5 in tall with terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e86 lb (39.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e10 years (see Briggs \u0026amp; Stratton's warranty document for complete terms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e48 V battery inverter or inverter\/charger:\u003c\/strong\u003e Turns the battery's DC power into AC power for your loads, and usually charges the battery too. Choose one rated for a 48 V battery and sized for your loads, then program it with Briggs \u0026amp; Stratton's PHI battery settings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/cable-wiring\"\u003eBattery cables\u003c\/a\u003e:\u003c\/strong\u003e Connect the battery to the inverter and to other batteries. Briggs \u0026amp; Stratton lists 6 AWG as the minimum, but its installation manual says each battery's leads are typically 4 AWG, sized to the battery's built-in breaker, and local code may require sizing to the breaker or to the battery's surge rating. The terminals are 3\/8 in (10 mm).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/disconnects-breakers\"\u003eOvercurrent protection and disconnects\u003c\/a\u003e:\u003c\/strong\u003e The battery has its own breaker. Briggs \u0026amp; Stratton's manual also calls for breakers, disconnects and fuses at several points in the system so each part can be isolated and protected. Ratings come from electrical code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHybrid inverter or solar charge controller:\u003c\/strong\u003e Needed if solar panels will charge the battery. A hybrid inverter combines the inverter and solar charger in one unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMore PHI-3.8-48-M batteries:\u003c\/strong\u003e To store more energy or deliver more continuous power. Add only more of the same 48 V model, connected in parallel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/collections\/system-monitors-displays\"\u003eBattery or system monitoring\u003c\/a\u003e:\u003c\/strong\u003e Shows state of charge and system activity. Check Briggs \u0026amp; Stratton documentation to confirm which monitoring products it lists for the PHI 3.8-M.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eParallel only, never series.\u003c\/strong\u003e PHI batteries are built to run at a fixed voltage. Briggs \u0026amp; Stratton's manual says wiring them in series to raise voltage will damage them. Don't mix this 48 V model with the 24 V PHI-3.8-24-M.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize the battery bank for your inverter.\u003c\/strong\u003e Briggs \u0026amp; Stratton's product page says battery bank-to-inverter output sizing should follow a 2:1 ratio. The installation manual explains how to size for both discharge and charge rates. Going over the battery's charge or discharge limits voids the warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUse the manufacturer's inverter settings.\u003c\/strong\u003e Inverters and charge controllers must be programmed to Briggs \u0026amp; Stratton's settings for the PHI battery. Wrong settings void the warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFully charge before first use.\u003c\/strong\u003e The manual says to fully charge PHI batteries before connecting loads, and to check polarity with a voltmeter before turning on the breaker.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature.\u003c\/strong\u003e Don't charge below 32°F (0°C). Charging in sub-freezing temperatures voids the warranty.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation.\u003c\/strong\u003e The battery is not ignition-protected. Don't install it where ignition-protected equipment is required, such as a confined space with vented batteries, natural gas, liquid petroleum gas (LPG) or gasoline. It can be mounted terminals-up or on its side, but never upside down with the terminals facing the floor. The specification sheet doesn't list an outdoor or enclosure rating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight and installation.\u003c\/strong\u003e Each battery weighs 86 lb. Fuses, breakers and wire sizes should follow electrical code, and Briggs \u0026amp; Stratton recommends review by certified electricians or licensed installers.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Briggs \u0026 Stratton","offers":[{"title":"Default Title","offer_id":46793368862939,"sku":"PHI-3.8-48-M","price":2935.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/original.jpg?v=1747340864","url":"https:\/\/www.altestore.com\/products\/briggs-stratton-phi-3-8-m-3-87kwh-48v-lfp-battery","provider":"AltE Store","version":"1.0","type":"link"}