{"product_id":"apsmart-transmitter-plc-outdoor-kit-single-core-85-264vac-power-supply-408006","title":"APsmart Transmitter-PLC Outdoor Kit, Single Core, 85–264VAC Power Supply – 408006","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe APsmart 408006 is the Single Core Transmitter-PLC Outdoor Kit with an 85–264 VAC power supply. APsmart says the kit includes a Transmitter-PLC with one core, an outdoor enclosure and the power supply.\u003c\/p\u003e\n\u003cp\u003eWhile powered, the Transmitter-PLC sends a signal to APsmart RSD units that keeps their PV modules connected. When the transmitter is switched off, the RSD units enter rapid shutdown, and they resume when power returns. APsmart's Outdoor Kit datasheet says the kit meets NEC 2017, 2020\u0026amp;2023 (690.12) requirements and SunSpec requirements.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAPsmart RSD-S-PLC systems that need an external transmitter:\u003c\/strong\u003e Where the inverter does not include an integrated SunSpec-certified transmitter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential sites with an 85–264 VAC supply:\u003c\/strong\u003e APsmart lists this supply as its residential option. Single core.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePLC rapid shutdown transmitter outdoor kit, single core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e408006: Single Core Transmitter-PLC Outdoor Kit, 85-264VAC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter input (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e12 VDC; 0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e85–264 VAC input, 12 VDC output; 90 × 17.5 × 58.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e~29 mm wire opening \/ 65 mm outside; 1500 VDC maximum system voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings per core, without connector (per APsmart)\u003c\/td\u003e\n\u003ctd\u003eCable Φ5.9 mm: ≤15; Φ6.35 mm: ≤15; Φ7 mm: ≤14; Φ8.6 mm: ≤10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum string length (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e30 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum cable length, inverter (+) to inverter (−) (per APsmart manual)\u003c\/td\u003e\n\u003ctd\u003e1500 ft (450 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit temperature (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e−40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit dimensions (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e198.5 × 298 × 179 mm (W × H × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNEC 690.12 (per APsmart)\u003c\/td\u003e\n\u003ctd\u003eMeets NEC 2017, 2020\u0026amp;2023 (690.12) requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty (per APsystems)\u003c\/td\u003e\n\u003ctd\u003e3 years from the warranty start date, when used with APsystems Rapid Shutdown Devices\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eAPsmart Transmitter-PLC Outdoor Kit Datasheet NA Rev 2.8; APsmart RSD-S-PLC \/ Transmitter User Manual NA Rev 4.4; APsmart Transmitter-PLC Outdoor Kit QIG Rev 2.4 NA; APsystems Limited Warranty for Rapid Shutdown Devices \u0026amp; Transmitter, US L3.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAPsmart RSD units on the modules:\u003c\/strong\u003e See the \u003ca href=\"\/products\/apsmart-rapid-shutdown-module-apsm-rsd-s-plc-415\"\u003eAPsmart RSD-S-PLC\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAn 85–264 VAC supply on the inverter's AC branch circuit.\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid shutdown labels:\u003c\/strong\u003e APsmart says to place the rapid shutdown system label within 1 m (3 ft) of the Transmitter-PLC or AC disconnect. See \u003ca href=\"\/products\/pv-labels-05-523-value-pack-88-pcs-2023-nec\"\u003ePV Labels 05-523 (2023 NEC)\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit fittings:\u003c\/strong\u003e APsmart says the enclosure is not punched before delivery. The manual gives drilling guides for 3\/4\" and 1\" conduit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther rapid shutdown parts:\u003c\/strong\u003e See \u003ca href=\"\/collections\/rapid-shutdown\"\u003erapid shutdown\u003c\/a\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame AC branch circuit.\u003c\/strong\u003e APsmart's user manual says the power supply of the Transmitter-PLC and the inverter MUST be on the same AC branch circuit to meet rapid shutdown requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCore routing.\u003c\/strong\u003e Pass either both positive or both negative cables through a core, never one of each, and follow the core diagrams in APsmart's current user manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall order.\u003c\/strong\u003e APsmart says to install the RSD-S-PLC units before powering the Transmitter-PLC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter list.\u003c\/strong\u003e For inverters with an integrated SunSpec-certified transmitter, check the APsmart Compatible Inverters list (apsmartglobal.com), viewed Oct 8, 2026; no revision number.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter pairing.\u003c\/strong\u003e Do not assume a specific string inverter, hybrid inverter or microinverter model is listed. Check the maker's current certified list and the document revision or view date before design.\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"APsmart","offers":[{"title":"Default Title","offer_id":50587698135259,"sku":"408006","price":250.53,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/408006.jpg?v=1791314772","url":"https:\/\/www.altestore.com\/products\/apsmart-transmitter-plc-outdoor-kit-single-core-85-264vac-power-supply-408006","provider":"AltE Store","version":"1.0","type":"link"}