{"product_id":"aps-apsmart-transmitter-plc-outdoor-kit-dual-core-408007","title":"APsmart Transmitter-PLC Outdoor Kit, Dual Core, 85–264VAC Power Supply – 408007","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe APsmart 408007 is the Dual Core Transmitter-PLC Outdoor Kit with an 85–264 VAC power supply. APsmart's Outdoor Kit datasheet lists 408007 as \"Dual Core Transmitter-PLC-Outdoor Kit, 85-264VAC Power Supply.\" The kit includes a Transmitter-PLC with two cores, an outdoor enclosure, and the power supply.\u003c\/p\u003e\n\u003cp\u003eWhile powered, the Transmitter-PLC sends a signal to APsmart RSD units that keeps their PV modules connected. When the transmitter is switched off, the RSD units enter rapid shutdown, and they resume when power returns. APsmart's Outdoor Kit datasheet says the kit meets NEC 2017, 2020\u0026amp;2023 (690.12) requirements and SunSpec requirements.\u003c\/p\u003e\n\u003cp\u003eThis listing is the dual-core sibling of AltE's \u003ca href=\"\/products\/aps-apsmart-transmitter-plc-outdoor-kit-single-core-408006\"\u003e408006 Single Core Outdoor Kit\u003c\/a\u003e (same 85–264 VAC supply). APsmart's ordering table lists 408006 as single core and 408007 as dual core. The Outdoor Kit datasheet rates dual-core maximum current at 320 A (160 A × 2).\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAPsmart RSD systems that need an external transmitter with two cores:\u003c\/strong\u003e Where the inverter does not include an integrated SunSpec-certified transmitter, and the design calls for dual-core current capacity (APsmart: 160 A per core, 320 A total).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResidential sites with an 85–264 VAC supply:\u003c\/strong\u003e APsmart lists the 85–264 VAC supply as its residential option for this Outdoor Kit ordering family. Dual core (part 408007).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePLC rapid shutdown transmitter outdoor kit, dual core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart number (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e408007: Dual Core Transmitter-PLC Outdoor Kit, 85-264VAC Power Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDifference from 408006 (per APsmart ordering table)\u003c\/td\u003e\n\u003ctd\u003e408006 = Single Core, 85–264 VAC; 408007 = Dual Core, 85–264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmitter input (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e12 VDC; 0.8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e85–264 VAC input, 12 VDC output; 90 × 17.5 × 58.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore \/ current (per APsmart Outdoor Kit datasheet)\u003c\/td\u003e\n\u003ctd\u003eDual core; max current 320 A (160 A × 2); ~29 mm wire opening \/ 65 mm outside; 1500 VDC maximum system voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStrings per core, without connector (per APsmart)\u003c\/td\u003e\n\u003ctd\u003eCable Φ5.9 mm: ≤15; Φ6.35 mm: ≤15; Φ7 mm: ≤14; Φ8.6 mm: ≤10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum string length (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e30 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum cable length, inverter (+) to inverter (−) (per APsmart user manual)\u003c\/td\u003e\n\u003ctd\u003e1500 ft (450 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit temperature (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e−40°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit dimensions (per APsmart)\u003c\/td\u003e\n\u003ctd\u003e198.5 × 298 × 179 mm (W × H × D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure rating (per APsmart Outdoor Kit datasheet)\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNEC 690.12 (per APsmart)\u003c\/td\u003e\n\u003ctd\u003eMeets NEC 2017, 2020\u0026amp;2023 (690.12) requirements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty (per APsystems)\u003c\/td\u003e\n\u003ctd\u003e3 years from the warranty start date, when used with APsystems Rapid Shutdown Devices (Transmitter-PLC Outdoor Kit line)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eAPsmart Transmitter-PLC Outdoor Kit Datasheet NA Rev 2.8 (2023-10-07); APsmart RSD-S-PLC \/ Transmitter-PLC User Manual NA Rev 3.8 (2024-07-08); APsmart Transmitter-PLC Outdoor Kit QIG Rev 2.4 NA; APsystems Limited Warranty for Rapid Shutdown Devices \u0026amp; Transmitter, US L3.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAPsmart RSD units on the modules:\u003c\/strong\u003e See the \u003ca href=\"\/products\/apsmart-rapid-shutdown-module-apsm-rsd-s-plc-415\"\u003eAPsmart RSD-S-PLC\u003c\/a\u003e. APsmart documents the Transmitter-PLC Outdoor Kit as part of a rapid shutdown solution when paired with APsmart RSD.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAn 85–264 VAC supply on the inverter's AC branch circuit.\u003c\/strong\u003e APsmart's user manual says the Transmitter-PLC power supply and the inverter must be on the same AC branch circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid shutdown initiator \/ emergency stop:\u003c\/strong\u003e APsmart shows an optional emergency stop button box that disconnects transmitter AC power. AltE also lists the \u003ca href=\"\/products\/aps-apsmart-rapid-shutdown-initiator-switch-bg10p34-11\"\u003eAPsmart Rapid Shutdown Initiator Switch (BG10P34-11)\u003c\/a\u003e; confirm current APsmart documentation for how an initiator is wired on your design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRapid shutdown labels:\u003c\/strong\u003e See \u003ca href=\"\/products\/pv-labels-05-523-value-pack-88-pcs-2023-nec\"\u003ePV Labels 05-523 (2023 NEC)\u003c\/a\u003e or other NEC label packs AltE carries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConduit fittings:\u003c\/strong\u003e APsmart says the Outdoor Kit enclosure is not punched before delivery; the installer drills openings for conduit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional related equipment\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOther rapid shutdown parts:\u003c\/strong\u003e See \u003ca href=\"\/collections\/rapid-shutdown\"\u003erapid shutdown\u003c\/a\u003e, including the \u003ca href=\"\/products\/aps-apsmart-transmitter-plc-outdoor-kit-single-core-408006\"\u003eSingle Core Outdoor Kit (408006)\u003c\/a\u003e when a single-core design is specified instead.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware. Matching voltage or protocol does not by itself confirm that two products are supported together.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSame AC branch circuit.\u003c\/strong\u003e APsmart's user manual says the power supply of the Transmitter-PLC and the inverter MUST be on the same AC branch circuit to meet rapid shutdown requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCore routing.\u003c\/strong\u003e APsmart diagrams say to homerun only PV+ cable through the core (or follow the current manual's positive-or-negative-through-core rules). Do not mix polarities through one core. Fix cores to prevent swing damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall order.\u003c\/strong\u003e APsmart says to install the RSD-S-PLC units before powering the Transmitter-PLC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual core vs single core.\u003c\/strong\u003e Choose 408007 when the design needs dual cores \/ 320 A total core current per APsmart's Outdoor Kit datasheet. Choose \u003ca href=\"\/products\/aps-apsmart-transmitter-plc-outdoor-kit-single-core-408006\"\u003e408006\u003c\/a\u003e when APsmart's single-core ordering line is specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInverter pairing.\u003c\/strong\u003e Do not assume a specific string inverter, hybrid inverter or microinverter model is listed. For inverters with an integrated SunSpec-certified transmitter, APsmart says the external transmitter may not be required—check APsmart's current compatible-inverters documentation before design.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"APsmart","offers":[{"title":"Default Title","offer_id":51021960118491,"sku":"408007","price":330.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/DocTemplates_ItemImage_300251000001828603.png?v=1793662305","url":"https:\/\/www.altestore.com\/products\/aps-apsmart-transmitter-plc-outdoor-kit-dual-core-408007","provider":"AltE Store","version":"1.0","type":"link"}