{"title":"Load Centers \u0026 Panels","description":"\u003c!-- alte-load-centers-hub-2026-10-07 --\u003e\n\u003cp\u003eA load center (breaker panel) takes incoming 120\/240 V single-phase power and distributes it to branch circuits through plug-in breakers. In solar and battery projects it is often where the PV system ties into the home, or where backed-up \"critical loads\" are grouped on their own panel. This collection covers Eaton Type BR load centers: solar-ready meter main combos, main-breaker panels, and a compact main-lug subpanel. All of them use Eaton Type BR breakers.\u003c\/p\u003e\n\u003ch2\u003eBest for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential service upgrades that add solar, using a meter main combo with factory PV provisions\u003c\/li\u003e\n\u003cli\u003eCritical-load or backup subpanels for battery and hybrid inverter systems\u003c\/li\u003e\n\u003cli\u003eAdding branch circuits indoors or outdoors with Eaton Type BR breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhich load center fits your project\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/eaton-200a-solar-ready-meter-main-combo-load-center-surface-mounted-mbe2040pv200bts\"\u003eEaton Solar-Ready Meter Main Combo, Surface Mount (MBE2040PV200BTS)\u003c\/a\u003e\u003c\/strong\u003e and \u003cstrong\u003e\u003ca href=\"\/products\/eaton-mbe2040pv200btf-solar-rated-mb-20-40-200a-mcb-225a-bus-br-breakers\"\u003eFlush Mount (MBE2040PV200BTF)\u003c\/a\u003e\u003c\/strong\u003e. Each one puts a utility meter socket, a 200 A main breaker, and 20 spaces \/ 40 circuits of Type BR distribution in one NEMA 3R enclosure. Per Eaton, the 225 A copper bus allows up to 70 A of PV input. Pick surface or flush mounting to suit the wall.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/eaton-100a-critical-load-panel-load-center-surface-mounted-brp12b100r\"\u003eEaton Critical Load Panel \/ Load Center (BRP12B100R)\u003c\/a\u003e\u003c\/strong\u003e. A 125 A plug-on neutral main-breaker load center with 12 spaces \/ 24 circuits in a metallic NEMA 3R enclosure. Its compact size suits a critical-load or backup subpanel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/eaton-200a-load-center-surface-mounted-brp30b200\"\u003eEaton 200A Load Center (BRP30B200)\u003c\/a\u003e\u003c\/strong\u003e. A 200 A plug-on neutral main-breaker load center with 30 spaces \/ 60 circuits and a 25 kAIC interrupt rating. It has a NEMA 1 enclosure, so it is for indoor, dry locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/eaton-br816l125rp-1-ph-br-loadcenter-125a-mlo-8-16-cir-al-bus-nema-3r-br-breakers\"\u003eEaton BR 125A Main Lug Load Center (BR816L125RP)\u003c\/a\u003e\u003c\/strong\u003e. A 125 A main-lug-only panel with 8 spaces \/ 16 circuits in a NEMA 3R enclosure. With no main breaker of its own, it must be protected by a correctly sized upstream breaker, which makes it a common choice for small subpanels.\u003c\/p\u003e\n\u003ch2\u003eImportant considerations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA 3R enclosures are rainproof for outdoor mounting. NEMA 1 is for indoor, dry locations only.\u003c\/li\u003e\n\u003cli\u003eMain breaker vs. main lug: a main-lug panel needs upstream overcurrent protection sized for the panel and its feeder.\u003c\/li\u003e\n\u003cli\u003eMeter main combos must meet your utility's meter-socket requirements. Confirm with the utility before ordering.\u003c\/li\u003e\n\u003cli\u003eUse only breakers listed for Eaton Type BR load centers, and size PV or backfed breakers to your inverter output and local code.\u003c\/li\u003e\n\u003cli\u003eFull ratings are on each product page and on Eaton's specification sheets. Professional installation is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/collections\/disconnects-breakers\"\u003ebreakers and disconnects\u003c\/a\u003e, \u003ca href=\"\/collections\/enclosures-electrical-and-safety\"\u003eelectrical and safety equipment\u003c\/a\u003e, \u003ca href=\"\/collections\/combiner-boxes\"\u003ecombiner boxes\u003c\/a\u003e, and \u003ca href=\"\/collections\/solar-batteries\"\u003esolar batteries\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eLoad center FAQ\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is a solar-ready meter main combo?\u003c\/summary\u003e\n\u003cp\u003eIt combines the utility meter socket, a main breaker, and a breaker panel in one outdoor enclosure, with factory provisions for connecting a PV system. The Eaton MBE2040PV200BTS and MBE2040PV200BTF have a 200 A main and a 225 A copper bus that allows up to 70 A of PV input, per Eaton.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between a main-breaker and a main-lug load center?\u003c\/summary\u003e\n\u003cp\u003eA main-breaker panel has its own main breaker, which protects the whole panel and can act as its disconnect. A main-lug panel, such as the BR816L125RP, has no main breaker. The feeder lands on lugs and must be protected by a breaker upstream, which is why main-lug panels are often used as subpanels.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan these load centers be installed outdoors?\u003c\/summary\u003e\n\u003cp\u003eThe two meter main combos, the BRP12B100R, and the BR816L125RP have NEMA 3R (rainproof) enclosures for outdoor mounting. The BRP30B200 has a NEMA 1 enclosure, so it is for indoor, dry locations only.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhich breakers do these panels use?\u003c\/summary\u003e\n\u003cp\u003eAll five use Eaton Type BR breakers. Use only breakers listed for Type BR load centers, and follow Eaton's installation instructions for hold-down requirements on backfed PV or battery breakers.\u003c\/p\u003e\n\u003c\/details\u003e\n","products":[{"product_id":"eaton-br816l125rp-1-ph-br-loadcenter-125a-mlo-8-16-cir-al-bus-nema-3r-br-breakers","title":"Eaton BR Single-Phase Load Center, 125A Main Lug, 8\/16 Circuit, NEMA 3R – BR816L125RP","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Eaton BR816L125RP is a 125 A main-lug-only (MLO) Type BR loadcenter in a NEMA 3R outdoor enclosure. Main-lug means there is no factory main breaker — the panel is fed through lugs and is typically protected by an upstream breaker or used as a subpanel.\u003c\/p\u003e\n\u003cp\u003eWith 8 spaces and 16 circuits on an aluminum bus, it is a compact outdoor panel for limited branch circuits. Dual grounds and an included cover support a complete install.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor subpanels or small distribution points at up to 125 A\u003c\/li\u003e\n\u003cli\u003eProjects using Type BR breakers in a rainproof enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain lug only (no factory main breaker)\u003c\/li\u003e\n\u003cli\u003e8 spaces \/ 16 circuits\u003c\/li\u003e\n\u003cli\u003eAluminum bus; cover included; dual grounds\u003c\/li\u003e\n\u003cli\u003eNEMA 3R metallic outdoor enclosure\u003c\/li\u003e\n\u003cli\u003eAccepts Type BR 1-inch breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCatalog number: BR816L125RP\u003c\/li\u003e\n\u003cli\u003eAmperage: 125 A (main lug)\u003c\/li\u003e\n\u003cli\u003eVoltage: 120\/240 V, single-phase, three-wire\u003c\/li\u003e\n\u003cli\u003eSpaces \/ circuits: 8 \/ 16\u003c\/li\u003e\n\u003cli\u003eInterrupt rating: 10 kAIC\u003c\/li\u003e\n\u003cli\u003eBus: aluminum\u003c\/li\u003e\n\u003cli\u003eEnclosure: NEMA 3R, metallic\u003c\/li\u003e\n\u003cli\u003eBreaker family: Type BR\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \/ Important Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUpstream overcurrent protection must be sized correctly for an MLO panel.\u003c\/li\u003e\n\u003cli\u003eProfessional installation required.\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- alte-lc-links-2026-10-07 --\u003e\u003ca href=\"\/collections\/load-centers\"\u003eCompare all Eaton load centers \u0026amp; meter mains\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Rexel","offers":[{"title":"Default Title","offer_id":46654957289691,"sku":"BR816L125RP","price":190.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/BR816L125RP_DO.jpg?v=1743458067"},{"product_id":"eaton-mbe2040pv200btf-solar-rated-mb-20-40-200a-mcb-225a-bus-br-breakers","title":"Eaton Solar-Ready Meter Main Combo Load Center, 200A, Flush Mount – MBE2040PV200BTF","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Eaton MBE2040PV200BTF is a solar-ready Type BR meter breaker (Solar Power Center) with a 200 A main, 225 A copper bus, and flush mounting. Like the surface-mount BTS sibling, it combines meter socket, main breaker, and branch spaces for utility-plus-PV service in one outdoor assembly.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlush-mount solar-ready meter main combo installations\u003c\/li\u003e\n\u003cli\u003eResidential interconnects specifying Eaton MBE2040PV200BTF\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBR solar-ready meter breaker\u003c\/li\u003e\n\u003cli\u003e200 A main; 225 A copper bus\u003c\/li\u003e\n\u003cli\u003eGalvanized steel outdoor enclosure\u003c\/li\u003e\n\u003cli\u003eOverhead \/ underground feed\u003c\/li\u003e\n\u003cli\u003eFlush mounting\u003c\/li\u003e\n\u003cli\u003eSingle-phase 120\/240 V; Type BR breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCatalog number: MBE2040PV200BTF\u003c\/li\u003e\n\u003cli\u003eMain amperage: 200 A\u003c\/li\u003e\n\u003cli\u003eBus: copper, 225 A\u003c\/li\u003e\n\u003cli\u003eVoltage: 120\/240 V, single-phase\u003c\/li\u003e\n\u003cli\u003eInterrupt rating: 22 kAIC\u003c\/li\u003e\n\u003cli\u003eMounting: flush\u003c\/li\u003e\n\u003cli\u003eFeed: overhead \/ underground\u003c\/li\u003e\n\u003cli\u003eUsed with: Type BR breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \/ Important Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThis is the flush (BTF) version — distinct from surface-mount MBE2040PV200BTS.\u003c\/li\u003e\n\u003cli\u003eConfirm utility meter and solar interconnect requirements with the AHJ \/ utility.\u003c\/li\u003e\n\u003cli\u003eProfessional installation required.\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- alte-lc-links-2026-10-07 --\u003e\u003ca href=\"\/collections\/load-centers\"\u003eCompare all Eaton load centers \u0026amp; meter mains\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Rexel","offers":[{"title":"Default Title","offer_id":46654964629723,"sku":"MBE2040PV200BTF","price":433.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/MBE2040PV200BTF_C.jpg?v=1743458262"},{"product_id":"eaton-100a-critical-load-panel-load-center-surface-mounted-brp12b100r","title":"Eaton Critical Load Panel \/ Load Center, Surface Mount – BRP12B100R","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Eaton BRP12B100R is a Type BR plug-on neutral main breaker loadcenter in a rainproof outdoor enclosure. It distributes 120\/240 V single-phase power to branch circuits and is commonly used as a critical-loads or backup subpanel when you need a compact outdoor-rated panel for essential circuits.\u003c\/p\u003e\n\u003cp\u003eThis unit uses Eaton Type BR 1-inch breakers and a plug-on neutral design that can reduce neutral pigtail clutter in the wiring gutters. NEMA 3R means the enclosure is rainproof for outdoor wall mounting (still keep openings and knockouts sealed per code and the installation instructions).\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor or damp-location critical-load panels for backup \/ hybrid systems\u003c\/li\u003e\n\u003cli\u003eCompact 12-space residential branch distribution at 120\/240 V\u003c\/li\u003e\n\u003cli\u003eInstallations that specify Eaton Type BR breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain breaker loadcenter with plug-on neutral\u003c\/li\u003e\n\u003cli\u003e12 spaces \/ 24 circuits (supports tandem BR breakers where allowed)\u003c\/li\u003e\n\u003cli\u003eAluminum bus; cover included\u003c\/li\u003e\n\u003cli\u003eMetallic NEMA 3R enclosure for outdoor use\u003c\/li\u003e\n\u003cli\u003eCombination mounting (surface or flush, per enclosure design)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCatalog number: BRP12B100R\u003c\/li\u003e\n\u003cli\u003eAmperage rating: 125 A (Eaton catalog)\u003c\/li\u003e\n\u003cli\u003eVoltage: 120\/240 V, single-phase, three-wire\u003c\/li\u003e\n\u003cli\u003eInterrupt rating: 10 kAIC\u003c\/li\u003e\n\u003cli\u003eBus: aluminum\u003c\/li\u003e\n\u003cli\u003eSpaces \/ circuits: 12 \/ 24\u003c\/li\u003e\n\u003cli\u003eEnclosure: NEMA 3R, metallic; box size X1\u003c\/li\u003e\n\u003cli\u003eBreaker family: Type BR 1-inch\u003c\/li\u003e\n\u003cli\u003eCertifications: UL 50, UL 67\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \/ Important Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUse only breakers listed for Type BR loadcenters.\u003c\/li\u003e\n\u003cli\u003eConfirm main breaker size, wire sizing, and grounding with your system design and local AHJ.\u003c\/li\u003e\n\u003cli\u003eProfessional installation required. Follow Eaton instructions and the NEC.\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- alte-lc-links-2026-10-07 --\u003e\u003ca href=\"\/collections\/load-centers\"\u003eCompare all Eaton load centers \u0026amp; meter mains\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":50587698430171,"sku":"BRP12B100R","price":447.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/BRP12B100R.jpg?v=1791314996"},{"product_id":"eaton-200a-load-center-surface-mounted-brp30b200","title":"Eaton Load Center, 200A, Surface Mount – BRP30B200","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Eaton BRP30B200 is a Type BR plug-on neutral main breaker loadcenter for indoor 120\/240 V single-phase distribution. At 200 A with 30 spaces and 60 circuits, it is sized for many whole-home service panels or large subpanels where you need room for branch breakers.\u003c\/p\u003e\n\u003cp\u003ePlug-on neutral simplifies branch neutral connections compared with wiring every neutral to a bar with pigtails. The panel ships with a ground bar and the BREQS125 hold-down screw kit for backfed breaker applications where required.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndoor residential main or large subpanel service at 200 A\u003c\/li\u003e\n\u003cli\u003eProjects standardized on Eaton Type BR breakers\u003c\/li\u003e\n\u003cli\u003eInstallations needing a plug-on neutral bus and high circuit count\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e200 A main breaker (CSR2200) plug-on neutral loadcenter\u003c\/li\u003e\n\u003cli\u003e30 spaces \/ 60 circuits\u003c\/li\u003e\n\u003cli\u003eAluminum bus; cover included\u003c\/li\u003e\n\u003cli\u003eIncludes ground bar and BREQS125 hold-down screw\u003c\/li\u003e\n\u003cli\u003eCombination surface\/flush mounting (NEMA 1 indoor enclosure)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCatalog number: BRP30B200\u003c\/li\u003e\n\u003cli\u003eAmperage rating: 200 A\u003c\/li\u003e\n\u003cli\u003eVoltage: 120\/240 V, single-phase\u003c\/li\u003e\n\u003cli\u003eInterrupt rating: 25 kAIC\u003c\/li\u003e\n\u003cli\u003eBus: aluminum\u003c\/li\u003e\n\u003cli\u003eSpaces \/ circuits: 30 \/ 60\u003c\/li\u003e\n\u003cli\u003eMain breaker: CSR2200\u003c\/li\u003e\n\u003cli\u003eEnclosure: NEMA 1, metallic; box size X6\u003c\/li\u003e\n\u003cli\u003eBreaker family: Type BR 1-inch\u003c\/li\u003e\n\u003cli\u003eCertifications: UL 50, UL 67\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \/ Important Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA 1 is for indoor \/ dry locations only — not rainproof.\u003c\/li\u003e\n\u003cli\u003eUse Type BR breakers only. Verify hold-down requirements when backfeeding.\u003c\/li\u003e\n\u003cli\u003eProfessional installation required. Follow Eaton instructions and the NEC.\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- alte-lc-links-2026-10-07 --\u003e\u003ca href=\"\/collections\/load-centers\"\u003eCompare all Eaton load centers \u0026amp; meter mains\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":50587698462939,"sku":"BRP30B200","price":760.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/BRP30B200.jpg?v=1791314999"},{"product_id":"eaton-200a-solar-ready-meter-main-combo-load-center-surface-mounted-mbe2040pv200bts","title":"Eaton Solar-Ready Meter Main Combo Load Center, 200A, Surface Mount – MBE2040PV200BTS","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Eaton MBE2040PV200BTS is a solar-ready meter main combo (Solar Power Center meter breaker) that combines a utility meter socket, 200 A main breaker, and a Type BR loadcenter in one outdoor NEMA 3R enclosure. It is designed so utility power and PV interconnect equipment share a single surface-mounted assembly.\u003c\/p\u003e\n\u003cp\u003eThe copper bus is rated 225 A with factory provisions for PV input (up to 70 A max PV input per Eaton). Side-by-side construction and permanent solar-related markings help support NEC labeling and layout for residential solar service upgrades.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResidential service upgrades that need a meter + main + branch panel in one outdoor enclosure\u003c\/li\u003e\n\u003cli\u003eSolar interconnects that specify an Eaton BR solar-ready meter breaker\u003c\/li\u003e\n\u003cli\u003eEUSERC-approved meter socket applications where required by the utility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAll-in-one meter \/ main \/ loadcenter for utility and PV\u003c\/li\u003e\n\u003cli\u003e200 A main, 225 A copper bus, Type BR branch breakers\u003c\/li\u003e\n\u003cli\u003e20 spaces \/ 40 circuits\u003c\/li\u003e\n\u003cli\u003eOverhead or underground feed; surface mounting\u003c\/li\u003e\n\u003cli\u003eNEMA 3R galvanized steel enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCatalog number: MBE2040PV200BTS\u003c\/li\u003e\n\u003cli\u003eMain amperage: 200 A\u003c\/li\u003e\n\u003cli\u003eBus rating \/ material: 225 A copper\u003c\/li\u003e\n\u003cli\u003eVoltage: 120\/240 V, single-phase\u003c\/li\u003e\n\u003cli\u003eSpaces \/ circuits: 20 \/ 40\u003c\/li\u003e\n\u003cli\u003eMeter sockets: 1\u003c\/li\u003e\n\u003cli\u003eMax PV input: 70 A (Eaton)\u003c\/li\u003e\n\u003cli\u003eInterrupt rating: 22 kAIC\u003c\/li\u003e\n\u003cli\u003eEnclosure: NEMA 3R, galvanized steel; surface mount\u003c\/li\u003e\n\u003cli\u003eFeed: overhead \/ underground (top\/bottom)\u003c\/li\u003e\n\u003cli\u003eUsed with: Type BR breakers\u003c\/li\u003e\n\u003cli\u003eCompliance: UL Listed; EUSERC Approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompatibility \/ Important Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm utility meter-socket and EUSERC requirements before ordering.\u003c\/li\u003e\n\u003cli\u003eThis is the surface-mount (BTS) version — not the flush (BTF) variant.\u003c\/li\u003e\n\u003cli\u003ePV breaker sizing and interconnection method must match the inverter\/output and local code.\u003c\/li\u003e\n\u003cli\u003eProfessional installation required.\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- alte-lc-links-2026-10-07 --\u003e\u003ca href=\"\/collections\/load-centers\"\u003eCompare all Eaton load centers \u0026amp; meter mains\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":50587698528475,"sku":"MBE2040PV200BTS","price":463.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/MBE2040PV200BTS.jpg?v=1791315004"}],"url":"https:\/\/www.altestore.com\/collections\/load-centers.oembed","provider":"AltE Store","version":"1.0","type":"link"}