{"title":"Load Centers \u0026 Panels","description":"\u003c!-- alte-load-centers-hub-2026-10-07 --\u003e\n\u003cp\u003eA load center (breaker panel) takes incoming 120\/240 V single-phase power and distributes it to branch circuits through plug-in breakers. In solar and battery projects it is often where the PV system ties into the home, or where backed-up \"critical loads\" are grouped on their own panel. This collection covers Eaton Type BR load centers: solar-ready meter main combos, main-breaker panels, and a compact main-lug subpanel. All of them use Eaton Type BR breakers.\u003c\/p\u003e\n\u003ch2\u003eBest for\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eResidential service upgrades that add solar, using a meter main combo with factory PV provisions\u003c\/li\u003e\n\u003cli\u003eCritical-load or backup subpanels for battery and hybrid inverter systems\u003c\/li\u003e\n\u003cli\u003eAdding branch circuits indoors or outdoors with Eaton Type BR breakers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eWhich load center fits your project\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/eaton-200a-solar-ready-meter-main-combo-load-center-surface-mounted-mbe2040pv200bts\"\u003eEaton Solar-Ready Meter Main Combo, Surface Mount (MBE2040PV200BTS)\u003c\/a\u003e\u003c\/strong\u003e and \u003cstrong\u003e\u003ca href=\"\/products\/eaton-mbe2040pv200btf-solar-rated-mb-20-40-200a-mcb-225a-bus-br-breakers\"\u003eFlush Mount (MBE2040PV200BTF)\u003c\/a\u003e\u003c\/strong\u003e. Each one puts a utility meter socket, a 200 A main breaker, and 20 spaces \/ 40 circuits of Type BR distribution in one NEMA 3R enclosure. Per Eaton, the 225 A copper bus allows up to 70 A of PV input. Pick surface or flush mounting to suit the wall.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/eaton-100a-critical-load-panel-load-center-surface-mounted-brp12b100r\"\u003eEaton Critical Load Panel \/ Load Center (BRP12B100R)\u003c\/a\u003e\u003c\/strong\u003e. A 125 A plug-on neutral main-breaker load center with 12 spaces \/ 24 circuits in a metallic NEMA 3R enclosure. Its compact size suits a critical-load or backup subpanel.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/eaton-200a-load-center-surface-mounted-brp30b200\"\u003eEaton 200A Load Center (BRP30B200)\u003c\/a\u003e\u003c\/strong\u003e. A 200 A plug-on neutral main-breaker load center with 30 spaces \/ 60 circuits and a 25 kAIC interrupt rating. It has a NEMA 1 enclosure, so it is for indoor, dry locations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"\/products\/eaton-br816l125rp-1-ph-br-loadcenter-125a-mlo-8-16-cir-al-bus-nema-3r-br-breakers\"\u003eEaton BR 125A Main Lug Load Center (BR816L125RP)\u003c\/a\u003e\u003c\/strong\u003e. A 125 A main-lug-only panel with 8 spaces \/ 16 circuits in a NEMA 3R enclosure. With no main breaker of its own, it must be protected by a correctly sized upstream breaker, which makes it a common choice for small subpanels.\u003c\/p\u003e\n\u003ch2\u003eImportant considerations\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA 3R enclosures are rainproof for outdoor mounting. NEMA 1 is for indoor, dry locations only.\u003c\/li\u003e\n\u003cli\u003eMain breaker vs. main lug: a main-lug panel needs upstream overcurrent protection sized for the panel and its feeder.\u003c\/li\u003e\n\u003cli\u003eMeter main combos must meet your utility's meter-socket requirements. Confirm with the utility before ordering.\u003c\/li\u003e\n\u003cli\u003eUse only breakers listed for Eaton Type BR load centers, and size PV or backfed breakers to your inverter output and local code.\u003c\/li\u003e\n\u003cli\u003eFull ratings are on each product page and on Eaton's specification sheets. Professional installation is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eRelated: \u003ca href=\"\/collections\/disconnects-breakers\"\u003ebreakers and disconnects\u003c\/a\u003e, \u003ca href=\"\/collections\/enclosures-electrical-and-safety\"\u003eelectrical and safety equipment\u003c\/a\u003e, \u003ca href=\"\/collections\/combiner-boxes\"\u003ecombiner boxes\u003c\/a\u003e, and \u003ca href=\"\/collections\/solar-batteries\"\u003esolar batteries\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch2\u003eLoad center FAQ\u003c\/h2\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is a solar-ready meter main combo?\u003c\/summary\u003e\n\u003cp\u003eIt combines the utility meter socket, a main breaker, and a breaker panel in one outdoor enclosure, with factory provisions for connecting a PV system. The Eaton MBE2040PV200BTS and MBE2040PV200BTF have a 200 A main and a 225 A copper bus that allows up to 70 A of PV input, per Eaton.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhat is the difference between a main-breaker and a main-lug load center?\u003c\/summary\u003e\n\u003cp\u003eA main-breaker panel has its own main breaker, which protects the whole panel and can act as its disconnect. A main-lug panel, such as the BR816L125RP, has no main breaker. The feeder lands on lugs and must be protected by a breaker upstream, which is why main-lug panels are often used as subpanels.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eCan these load centers be installed outdoors?\u003c\/summary\u003e\n\u003cp\u003eThe two meter main combos, the BRP12B100R, and the BR816L125RP have NEMA 3R (rainproof) enclosures for outdoor mounting. The BRP30B200 has a NEMA 1 enclosure, so it is for indoor, dry locations only.\u003c\/p\u003e\n\u003c\/details\u003e\n\u003cdetails\u003e\n\u003csummary\u003eWhich breakers do these panels use?\u003c\/summary\u003e\n\u003cp\u003eAll five use Eaton Type BR breakers. Use only breakers listed for Type BR load centers, and follow Eaton's installation instructions for hold-down requirements on backfed PV or battery breakers.\u003c\/p\u003e\n\u003c\/details\u003e\n","products":[{"product_id":"eaton-br816l125rp-1-ph-br-loadcenter-125a-mlo-8-16-cir-al-bus-nema-3r-br-breakers","title":"Eaton BR Single-Phase Load Center, 125A Main Lug, 8\/16 Circuit, NEMA 3R – BR816L125RP","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Eaton BR816L125RP is a Type BR main-lug-only (MLO) loadcenter rated 125 A. Main lug means there is no factory main breaker — the panel is fed through lugs and is typically protected by an upstream breaker or used as a subpanel.\u003c\/p\u003e\n\u003cp\u003eEaton lists 8 spaces \/ 16 circuits, an aluminum bus, a metallic NEMA 3R enclosure, surface mounting, and a cover included. It is intended for Type BR breakers.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor or rainproof subpanels:\u003c\/strong\u003e Where a compact 125 A main-lug Type BR panel in NEMA 3R is specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJobs that standardize on Eaton Type BR breakers:\u003c\/strong\u003e Matching branch breakers to this loadcenter family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eEaton BR main lug loadcenter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog number\u003c\/td\u003e\n\u003ctd\u003eBR816L125RP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage rating\u003c\/td\u003e\n\u003ctd\u003e125 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain type\u003c\/td\u003e\n\u003ctd\u003eMain lug (no factory main breaker)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpaces \/ circuits\u003c\/td\u003e\n\u003ctd\u003e8 spaces \/ 16 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus material\u003c\/td\u003e\n\u003ctd\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage rating\u003c\/td\u003e\n\u003ctd\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of wires\u003c\/td\u003e\n\u003ctd\u003eThree-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R, metallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSurface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCover\u003c\/td\u003e\n\u003ctd\u003eCover included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt rating\u003c\/td\u003e\n\u003ctd\u003e10 kAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire size\u003c\/td\u003e\n\u003ctd\u003e#14-1 AWG Cu\/Al\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed with\u003c\/td\u003e\n\u003ctd\u003eType BR breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 67; UL 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eEaton Specification Sheet for this catalog number (retrieved Oct 8, 2026)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eType BR branch breakers sized for each circuit (for example \u003ca href=\"\/products\/eaton-br220-type-br-breaker-20a-2-pole-120-240v\"\u003eBR220\u003c\/a\u003e \/ \u003ca href=\"\/products\/eaton-br240-type-br-breaker-40a-2-pole-120-240v\"\u003eBR240\u003c\/a\u003e family).\u003c\/li\u003e\n\u003cli\u003eUpstream overcurrent protection and feeders sized for a 125 A main-lug panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNeutral and ground kits as required by the installation instructions and local code.\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/disconnects-breakers\"\u003eDisconnects \u0026amp; Breakers\u003c\/a\u003e: Outdoor disconnects ahead of or beside the panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/enclosures-electrical-and-safety\"\u003eEnclosures, Electrical \u0026amp; Safety\u003c\/a\u003e: Related electrical balance-of-system hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMain-lug panels do not include a factory main breaker. Provide protection upstream as required.\u003c\/li\u003e\n\u003cli\u003eNEMA 3R is rainproof — keep openings and knockouts sealed per Eaton instructions and the NEC.\u003c\/li\u003e\n\u003cli\u003eUse only breakers listed for Type BR loadcenters.\u003c\/li\u003e\n\u003cli\u003eProfessional installation required.\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- alte-lc-links-2026-10-07 --\u003e\u003ca href=\"\/collections\/load-centers\"\u003eCompare all Eaton load centers \u0026amp; meter mains\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":46654957289691,"sku":"BR816L125RP","price":190.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/BR816L125RP_DO.jpg?v=1743458067"},{"product_id":"eaton-mbe2040pv200btf-solar-rated-mb-20-40-200a-mcb-225a-bus-br-breakers","title":"Eaton Solar-Ready Meter Main Combo Load Center, 200A, Flush Mount – MBE2040PV200BTF","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Eaton MBE2040PV200BTF is a Type BR solar-ready meter main (Solar Power Center Meter Breaker) rated 200 A. Eaton lists a copper bus rated 225 A, a NEMA 3R galvanized steel enclosure, flush mounting, and side-by-side construction.\u003c\/p\u003e\n\u003cp\u003eEaton lists 20 spaces \/ 40 circuits, a CSR main circuit breaker, 22 kAIC interrupt rating, top\/bottom feed, and a maximum PV input of 70. The unit is listed for Type BR breakers and is EUSERC Approved \/ UL Listed.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlush-mount solar-ready meter mains:\u003c\/strong\u003e Where utility metering and a Type BR distribution section are combined in one outdoor NEMA 3R assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProjects that specify Eaton Type BR breakers:\u003c\/strong\u003e Branch circuits in the distribution section of this meter main.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eEaton type BR solar power center meter breaker (solar-ready)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog number\u003c\/td\u003e\n\u003ctd\u003eMBE2040PV200BTF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage rating\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus material \/ bus rating\u003c\/td\u003e\n\u003ctd\u003eCopper \/ 225 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpaces \/ circuits\u003c\/td\u003e\n\u003ctd\u003e20 spaces \/ 40 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain circuit breaker\u003c\/td\u003e\n\u003ctd\u003eCSR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R, galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eFlush\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeed type\u003c\/td\u003e\n\u003ctd\u003eTop\/bottom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt rating\u003c\/td\u003e\n\u003ctd\u003e22 kAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV input (Eaton)\u003c\/td\u003e\n\u003ctd\u003e70 max PV input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage rating\u003c\/td\u003e\n\u003ctd\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of sockets\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial features\u003c\/td\u003e\n\u003ctd\u003eSide by side construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed with\u003c\/td\u003e\n\u003ctd\u003eType BR breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct compliance\u003c\/td\u003e\n\u003ctd\u003eEUSERC Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eEaton Specification Sheet for this catalog number (retrieved Oct 8, 2026)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eType BR branch breakers for the distribution section.\u003c\/li\u003e\n\u003cli\u003eUtility coordination for the meter socket and service.\u003c\/li\u003e\n\u003cli\u003eConductors and PV interconnection equipment sized per the design and AHJ.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/disconnects-breakers\"\u003eDisconnects \u0026amp; Breakers\u003c\/a\u003e: AC disconnects where the utility or AHJ requires a separate outdoor disconnect.\u003c\/li\u003e\n\u003cli\u003eEaton hold-down and accessory kits when backfeeding or when the instructions require them.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/enclosures-electrical-and-safety\"\u003eEnclosures, Electrical \u0026amp; Safety\u003c\/a\u003e: Related electrical balance-of-system hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm utility approval (EUSERC and local utility lists) before ordering.\u003c\/li\u003e\n\u003cli\u003eEaton Volume 15 lists this family as 70 A maximum total ampere rating of PV backfed mains (\"70 max PV input\" on the product sheet). Confirm how that limit applies to your interconnection design.\u003c\/li\u003e\n\u003cli\u003eUse only Type BR breakers in the distribution section.\u003c\/li\u003e\n\u003cli\u003eProfessional installation required. Follow Eaton instructions, utility rules, and the NEC.\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- alte-lc-links-2026-10-07 --\u003e\u003ca href=\"\/collections\/load-centers\"\u003eCompare all Eaton load centers \u0026amp; meter mains\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":46654964629723,"sku":"MBE2040PV200BTF","price":433.46,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/MBE2040PV200BTF_C.jpg?v=1743458262"},{"product_id":"eaton-100a-critical-load-panel-load-center-surface-mounted-brp12b100r","title":"Eaton Type BR Plug-On Neutral Load Center, 12-Space\/24-Circuit, NEMA 3R – BRP12B100R","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Eaton BRP12B100R is a Type BR plug-on neutral main circuit breaker loadcenter in a metallic NEMA 3R enclosure. Eaton lists 12 spaces \/ 24 circuits, an aluminum bus, combination mounting, a cover included, and use with Type BR 1-inch breakers.\u003c\/p\u003e\n\u003cp\u003eCheck the main ampere rating on the unit nameplate before sizing feeders.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompact Type BR outdoor\/damp-location panels:\u003c\/strong\u003e Where a plug-on neutral NEMA 3R loadcenter with 12 spaces is specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJobs standardized on Type BR 1-inch breakers:\u003c\/strong\u003e Matching branch breakers to this family.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePlug-on neutral main circuit breaker loadcenter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog number\u003c\/td\u003e\n\u003ctd\u003eBRP12B100R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpaces \/ circuits\u003c\/td\u003e\n\u003ctd\u003e12 spaces \/ 24 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus material\u003c\/td\u003e\n\u003ctd\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage rating\u003c\/td\u003e\n\u003ctd\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of wires\u003c\/td\u003e\n\u003ctd\u003eThree-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R, metallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eCombination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCover\u003c\/td\u003e\n\u003ctd\u003eCover included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt rating\u003c\/td\u003e\n\u003ctd\u003e10 kAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain circuit breaker\u003c\/td\u003e\n\u003ctd\u003eBR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed with\u003c\/td\u003e\n\u003ctd\u003eType BR 1-inch breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 50; UL 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eEaton Specification Sheet for this catalog number (retrieved Oct 8, 2026)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eType BR 1-inch branch breakers sized for each circuit.\u003c\/li\u003e\n\u003cli\u003eCheck the main ampere rating on the unit nameplate before ordering feeders.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/disconnects-breakers\"\u003eDisconnects \u0026amp; Breakers\u003c\/a\u003e: Outdoor disconnects as required by the design.\u003c\/li\u003e\n\u003cli\u003eGrounding and bonding accessories per Eaton instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/enclosures-electrical-and-safety\"\u003eEnclosures, Electrical \u0026amp; Safety\u003c\/a\u003e: Related electrical balance-of-system hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDo not size feeders from this page alone — check the main ampere rating on the unit nameplate and current Eaton documentation.\u003c\/li\u003e\n\u003cli\u003eUse only Type BR 1-inch breakers.\u003c\/li\u003e\n\u003cli\u003eNEMA 3R is rainproof — seal openings per instructions.\u003c\/li\u003e\n\u003cli\u003eProfessional installation required.\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- alte-lc-links-2026-10-07 --\u003e\u003ca href=\"\/collections\/load-centers\"\u003eCompare all Eaton load centers \u0026amp; meter mains\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":50587698430171,"sku":"BRP12B100R","price":447.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/BRP12B100R.jpg?v=1791314996"},{"product_id":"eaton-200a-load-center-surface-mounted-brp30b200","title":"Eaton Type BR Plug-On Neutral Load Center, 200A, 30-Space\/60-Circuit, NEMA 1 – BRP30B200","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Eaton BRP30B200 is a Type BR plug-on neutral main circuit breaker loadcenter rated 200 A. Eaton lists a CSR2200 main, 30 spaces \/ 60 circuits, an aluminum bus, a metallic NEMA 1 enclosure, combination mounting, a cover included, and a ground bar. The sheet also states it includes a BREQS125 hold-down screw.\u003c\/p\u003e\n\u003cp\u003eNEMA 1 is for indoor \/ dry locations. This is not a rainproof outdoor enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndoor Type BR main-breaker panels:\u003c\/strong\u003e Where a 200 A, 30-space plug-on neutral loadcenter is specified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJobs that need the included hold-down screw kit:\u003c\/strong\u003e Eaton lists BREQS125 with this catalog number.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003ePlug-on neutral main circuit breaker loadcenter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog number\u003c\/td\u003e\n\u003ctd\u003eBRP30B200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage rating\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain circuit breaker\u003c\/td\u003e\n\u003ctd\u003eCSR2200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpaces \/ circuits\u003c\/td\u003e\n\u003ctd\u003e30 spaces \/ 60 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus material\u003c\/td\u003e\n\u003ctd\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage rating\u003c\/td\u003e\n\u003ctd\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of wires\u003c\/td\u003e\n\u003ctd\u003eTwo hots, neutral and ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA 1, metallic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eCombination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCover\u003c\/td\u003e\n\u003ctd\u003eCover included\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterrupt rating\u003c\/td\u003e\n\u003ctd\u003e25 kAIC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial features\u003c\/td\u003e\n\u003ctd\u003eGround bar, includes BREQS125 hold-down screw\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed with\u003c\/td\u003e\n\u003ctd\u003eType BR 1-inch breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL 50; UL 67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eEaton Specification Sheet for this catalog number (retrieved Oct 8, 2026)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eType BR 1-inch branch breakers sized for each circuit.\u003c\/li\u003e\n\u003cli\u003eIndoor \/ dry mounting location suitable for NEMA 1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/disconnects-breakers\"\u003eDisconnects \u0026amp; Breakers\u003c\/a\u003e: Outdoor disconnects when the service design needs them ahead of this indoor panel.\u003c\/li\u003e\n\u003cli\u003eAdditional ground or accessory kits per Eaton instructions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/enclosures-electrical-and-safety\"\u003eEnclosures, Electrical \u0026amp; Safety\u003c\/a\u003e: Related electrical balance-of-system hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNEMA 1 is for indoor \/ dry locations only — not rainproof.\u003c\/li\u003e\n\u003cli\u003eUse Type BR breakers only. Verify hold-down requirements when backfeeding.\u003c\/li\u003e\n\u003cli\u003eProfessional installation required. Follow Eaton instructions and the NEC.\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- alte-lc-links-2026-10-07 --\u003e\u003ca href=\"\/collections\/load-centers\"\u003eCompare all Eaton load centers \u0026amp; meter mains\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":50587698462939,"sku":"BRP30B200","price":760.97,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/BRP30B200.jpg?v=1791314999"},{"product_id":"eaton-200a-solar-ready-meter-main-combo-load-center-surface-mounted-mbe2040pv200bts","title":"Eaton Solar-Ready Meter Main Combo Load Center, 200A, Surface Mount – MBE2040PV200BTS","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe Eaton MBE2040PV200BTS is a Type BR solar-ready meter main (Solar Power Center Meter Breaker) rated 200 A for surface mounting. Eaton lists a copper bus rated 225 A, a NEMA 3R galvanized steel enclosure, overhead\/underground feed, side-by-side construction, and use with Type BR breakers.\u003c\/p\u003e\n\u003cp\u003eEaton lists 20 spaces \/ 40 circuits, a CSR main, a maximum PV input of 70, and EUSERC Approved \/ UL Listed compliance.\u003c\/p\u003e\n\n\u003ch3\u003eBest For\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSurface-mount solar-ready meter mains:\u003c\/strong\u003e Where utility metering and a Type BR distribution section are combined outdoors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProjects that specify Eaton Type BR breakers:\u003c\/strong\u003e Branch circuits in the distribution section.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eKey Features \u0026amp; Specifications\u003c\/h3\u003e\n\u003ctable class=\"alte-spec-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct type\u003c\/td\u003e\n\u003ctd\u003eEaton type BR solar power center meter breaker (solar-ready)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCatalog number\u003c\/td\u003e\n\u003ctd\u003eMBE2040PV200BTS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmperage rating\u003c\/td\u003e\n\u003ctd\u003e200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus material \/ bus rating\u003c\/td\u003e\n\u003ctd\u003eCopper \/ 225 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpaces \/ circuits\u003c\/td\u003e\n\u003ctd\u003e20 spaces \/ 40 circuits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain circuit breaker\u003c\/td\u003e\n\u003ctd\u003eCSR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eNEMA 3R, galvanized steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eSurface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeed type\u003c\/td\u003e\n\u003ctd\u003eTop\/bottom (overhead\/underground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePV input (Eaton)\u003c\/td\u003e\n\u003ctd\u003e70 max PV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage rating\u003c\/td\u003e\n\u003ctd\u003e120\/240 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhase\u003c\/td\u003e\n\u003ctd\u003eSingle-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of sockets\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial features\u003c\/td\u003e\n\u003ctd\u003eSide by side construction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed with\u003c\/td\u003e\n\u003ctd\u003eType BR breakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct compliance\u003c\/td\u003e\n\u003ctd\u003eEUSERC Approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSource\u003c\/td\u003e\n\u003ctd\u003eEaton Specification Sheet for this catalog number (retrieved Oct 8, 2026)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eWhat You May Also Need\u003c\/h3\u003e\n\u003ch4\u003eUsually required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eType BR branch breakers for the distribution section.\u003c\/li\u003e\n\u003cli\u003eUtility coordination for the meter socket and service.\u003c\/li\u003e\n\u003cli\u003eConductors and PV interconnection equipment sized per the design and AHJ.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMay be required\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/disconnects-breakers\"\u003eDisconnects \u0026amp; Breakers\u003c\/a\u003e: AC disconnects where the utility or AHJ requires a separate outdoor disconnect.\u003c\/li\u003e\n\u003cli\u003eEaton hold-down and accessory kits when backfeeding or when the instructions require them.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eOptional upgrades\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"\/collections\/enclosures-electrical-and-safety\"\u003eEnclosures, Electrical \u0026amp; Safety\u003c\/a\u003e: Related electrical balance-of-system hardware.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eCheck current manufacturer documentation before combining components, especially batteries, inverters, communications equipment and system-control hardware.\u003c\/p\u003e\n\n\u003ch3\u003eImportant Considerations\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm utility approval (EUSERC and local utility lists) before ordering.\u003c\/li\u003e\n\u003cli\u003eEaton Volume 15 lists this family as 70 A maximum total ampere rating of PV backfed mains (\"70 max PV\" on the product sheet). Confirm how that limit applies to your interconnection design.\u003c\/li\u003e\n\u003cli\u003eUse only Type BR breakers in the distribution section.\u003c\/li\u003e\n\u003cli\u003eProfessional installation required.\u003c\/li\u003e\n\u003cli\u003e\n\u003c!-- alte-lc-links-2026-10-07 --\u003e\u003ca href=\"\/collections\/load-centers\"\u003eCompare all Eaton load centers \u0026amp; meter mains\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":50587698528475,"sku":"MBE2040PV200BTS","price":463.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0714\/3365\/0395\/files\/MBE2040PV200BTS.jpg?v=1791315004"}],"url":"https:\/\/www.altestore.com\/collections\/load-centers-panels.oembed","provider":"AltE Store","version":"1.0","type":"link"}