| Our Code: DAKLCB-16B |
![]() ![]() |
New flexibility improves system economy. For the 12/24V models, the choice of array voltage is independent of pump voltage. The array can be 12, 24 or 36V, to match or step down to a 12 or 24V pump. Increasing the array voltage reduces the wire size requirement exponentially. If you have a long wire run, place the controller at the pump so the long run is at the higher voltage.
Applications include
Dankoff Solar Slowpump and Solar Force Piston Pump,
Solarjack SDS & Shurflo pumps, jack pumps, fans, blowers
Features
SPECIFICATIONS:
VOLTS IN 12 / 24 / 36V nominal
VOLTS OUT 15.0 / 30.0 regulated
MAX. CONTINUOUS CURRENT 16 amps
STARTING CURRENT (15 seconds) DL-16A 36 amps
OUTPUT FUSE Type ATC or ATO (automotive) 15 and 20 amp fuses are included
REMOTE SWITCHING (float switch) Load disconnects when switch MAKES contact. 5V circuit.2-conductor cable required. #18 wire can go 2000 ft.
EFFICIENCY >94% at rated load
TEMP RANGE -20°C to +60°C
LIGHTNING PROTECTION: MOV (varistors)
ENCLOSURE powder coated steel, rainproof
DIMENSIONS 6"x 6"x 3" (15.5x15.5x7.5 cm)
WIRE SIZE #18 to #12
KNOCK OUTS combination 1/2" & 3/4"
WARRANTY five years