SPECIFICATIONS
|
| Input Power |
0.250 Watts @ 12 VDC* |
| Relay Contact Ratings: |
SS RLY- 5 amps DC motor @ 17vdc max
Action- 30 sec. delay ON; no delay OFF |
| Differential: |
Adjustable 8° to 24°F; fixed 4°F reset |
| High Limit: |
Adjustable from 110° to 200°F |
| Accuracy: |
+/- 1 °F |
| Environmental: |
-10 to 120 °F
0 to 95% RH |
| Temperature Sensors: |
10K @ 25°C/77°F Rated to 400°F |
| Dimensions: |
5”W x 6 ”H x 2.5”deep |
TEMPERATURE DIFFERENCE CONTROL
When the temperature difference between the sensor on the
solar collector and the sensor in the storage tank exceeds the dialed temperature difference setting (ON DIF),
the pump relay will actuate after a 30 second delay. The blue LED indicator will also turn ON. When the
temperature difference decreases and falls below 4 F (2.2 C), the pump relay and the blue LED indicator will
turn off without delay.
HIGH LIMIT CONTROL- When the temperature in the storage tank exceeds the HI-LIMIT dialed setting, the
PUMP relay will be turned OFF without delay regardless of the status of the temperature difference that exists
between the storage tank and the solar collector. The blue LED indicator will also turn OFF. When
the storage tank temperature falls 4 degrees below the setting in the HI-LIMT, the controller will then resume
normal operation. The pump relay will always have a 30 second delay before switching ON and the blue LED
will always show its STATUS condition.
LOW TEMPERATURE SHUT DOWN
This feature is available to prevent the system from operating at
low outdoor temperatures. If this feature is enabled normal operation will stop when the collector temperature
falls below 50 degrees F. The
pump relay will then be turned off. Normal control operation will not resume until
the collector temperature returns to 70 degrees or above. To enable this feature, a jumper must be placed onto the jumper pins marked "LO" on the circuit board.
Only ONE of these two override features can be enabled.
FREEZE PROTECTION OVERRIDE
This feature is available to prevent a non-drain back "water only" system
from freezing when the outdoor temperature drops too low. If this feature is enabled normal operation will stop
when the collector temperature falls below 37 F. The pump relay will then be turned ON until the
collector temperature reaches 52 F. Normal control operation will resume above this temperature. To
enable this feature, a jumper must be placed onto the jumper pins marked “FZ’ on the circuit board. Only ONE
of these two override features can be enabled.
STATUS INDICATION LEDS There are four status indication LEDS. The GREEN LED indicates that the
microprocessor is powered and the solar controller is running. The BLUE LED indicates pump operation.
When ON, the pump is operating and solar energy is being stored in the storage tank. The AMBER LED
indicates if the UPPER LIMIT temperature in the storage has been exceeded. The RED LED indicates when
there is a fault condition. The conditions that can cause the fault LED to turn ON are as follows: OPEN or
SHORTED or OUT of RANGE temperature sensors, pump relay switch not set to “AUT” (automatic)
position and internal component malfunctions. The RED LED will always be flashing when the FAULT
indication is ON.
SENSORS
Industrial 400°F (204°C) rated 10K IMC thermistors have +/- 1°F accuracy. When installed, they
will not exceed ONE degree of additional error for cable distances up to 1000 feet of 18ga., 700 feet of 20ga. or
500 feet of 22ga.
SENSOR SCREW TERMINALS
There are 9 screws on a GREEN block located at the top edge of the board.
These terminals accept solid or stranded wire from 18ga. to 22ga. They are NEC class 2 circuit connections.
POWER AND RELAY TERMINALS
This model operates from 4.75 Vdc to 22 Vdc@ 250 milliwatts Operation
below 4.75 Vdc is prevented by the smart power manager including initial pump start ups untill there is
sufficient PV power for proper pump operation. Operation above 22 Vdc could damage the controller and will
void the Warranty. The solid state relay is rated for 5 amps continuous load and has only normally open contacts. Its low side contacts are internally grounded. The pump is connected between the PV plus and the open relay terminal.

See more technical information and installation instructions about this differential temperature control in the Product Documentation section above! |