Basic Stats click to view hide

Our Code: BOGPM100D

Reviews click to view hide

There are currently no reviews. If you own this product write a review!

Add-Ons & Accessories click to view hide

These items are commonly used with the Bogart Engineering PM-100-D PentaMetric Display Unit

Similar Items click to view hide

These items are commonly in place of the Bogart Engineering PM-100-D PentaMetric Display Unit

Details click to view hide

You will also need to purchase separately a shunt for each load you are measuring. The pentametric can measure up to 5 loads.

Bogart EngineeringBogart Engineering
The PentaMetric Battery System Monitor
PM-5000-U Input Unit
PM-100-D Display Unit (shown)
PM-100-C Computer Interface

The new PentaMetric battery monitor system offers a lot more capability than the TriMetric monitor...

* Complete system consists of 3 parts: Input unit (near batteries), Display unit (shown) and computer interface unit
* Monitor up to 3 shunts--For example: measure total solar input and wind input independently in addition to monitoring battery "state of charge"
* Access the data with display unit (shown) with LCD display and buttons up to 1000 feet from batteries.
* Optional computer interface with (Windows) software to control and read out all data.
* Extensive system logged data
* Relay output to control generator or external alarm
* Audible and visual alarms for high and low battery conditions

The PentraMetric PM100D Battery System Monitor
PM-100D

Real Time Measurement Capability

Basic measurements:

Volts (2 channels) 8-100 volts. For example you can monitor volts from two battery systems. Or battery voltage, plus the solar array voltage if you have a peak power point tracking controller.

Amps (3 channels) ±.01-200 Amps (with 100A/100mV shunt).± 0.1-1000 Amps (with 500A/50mV shunt) Each of these requires a separate shunt. There are many different ways these can be used. For example one channel can be used to keep track of battery system energy content and the two remaining ones can be used for separate measurement of two charging sources, such as total solar or wind production. Or two battery systems can be separately monitored if they share a common negative connection--and in addition one charging source could be separately monitored.
Temperature -20 to +65 degrees C.

Secondary measurements derived from basic measurements

Amp hour (3 channels) to ±83,000 Amp-hours
Cumulative (negative) battery amp hours. (2 channels) to -1,000,000 amp-hours This measures accumulated amp hours (usually from a battery) only when the amps value is negative. Its purpose is to measure the total cumulative 'wear' of batteries during their lifetime.
Smoothed (time filtered) Amps, with time constants of 0.5, 2 or 8 minutes (3 channels) ±.01-200 Amps (100A/100mV shunt).± 0.1-1000 Amps (500A/50mV shunt) For example, this can be used to show a more accurage estimate of wind charging input when the wind source is varying in speed.
Smoothed (time filtered) Volts (2 channels) 0-100 Volts. The smoothed values for both Amps and Volts are used for triggering "alarm" and relay functions so very short term anomolies will be ignored.
Watts (2 channels) ±.01- 20,000 watts
Watt-hours (2 channels) ±21,000 kilowatt hours
Battery %full (2 channels) 0-100%
Days since batteries charged (2 channels) .01-250 days
Days since batteries equalized (2 channels) .01-250 days

Data logging functions

There are 3 types of data logging functions. With the computer interface all 3 types can be output to spreadsheet file.
1. "Periodically logged data" can record any or all of the following at regular intervals: once per day to up to once per minute:
* Amp hours (3 channels)
* Watt hours (2 channels)
* Temperature max/min (1 channel)
* Volts (2 channels)
* Amps (1 channel)
* Batt%Full (2 channels)
2. "Battery discharge voltage profile" data logs volts and amps every time charge level changes by 5% (or 10%) for 1 or 2 battery systems. This checks that battery capacity is still OK--by observing that battery voltage does not decline excessively as charge level drops.
3. "Battery cycle efficiency data" documents system efficiency for up to 2 battery systems. For each 'charge/discharge' cycle it records: cycle length (hours), total amp hours charged, total amp hours discharged, computed average 'self discharge' current and charge (amp hour) efficiency.

Controls and alarms

Relay output
Control external relay to go on and off at specified voltage levels and/or battery state of charge levels. "On" and "off" levels can be independently set.

Audible and visual alarms

Has audible or visual signal for 'Low voltage or low state of charge', 'High voltage', 'battery is charged', 'too many days since charged', and 'too many days since equalized'.

Warranty: The Bogart Engineering warranty policy is to repair at no cost any of their products that develop a problem not due to customer misuse.  

 

Bogart Engineering


Send to a friend Write a review Request more info
HACKER SAFE certified sites prevent over 99.9% of hacker crime. BizRate Customer Certified (GOLD) Site
Call us for solar panel system design help.
877-878-4060

Se habla Español
LiveZilla Live Help
 

browse by brand

 
 
Why buy from us? Sign up for our Newsletters Save / Earn Money Have a suggestion? Found a bug?

newsletters signup

Monthly Educational Newsletter
Specials
E-Mail:
Sign-Up