877-878-4060

We are no longer offering this product.

The below information is presented for informational purposes only. You may also find similar items in the category.
SHOP ALL PRODUCTS
V

Outback GTFX3048 3000W, 48V Inverter/Charger

Outback GTFX3048 3000W, 48V Inverter/Charger
Outback GTFX3048 3000W, 48V Inverter/Charger
 
Item code Brand name Model number Volts Watts Waveform
OUTGTFX3048 Outback GTFX3048 48V 3000W Pure
Pure sinewave grid-tie and backup power inverter.
DCC cover is included with all inverters.

Outback Power Systems
Grid Tied Inverter/Chargers
True Sine Wave
Sealed or Ventilated

Outback Power Systems

GTFX SeriesGTFX Series
Sealed Grid-Tie
Environmentally Tolerant
GTFX2524/ GTFX3048
GVFX Series

Ventilated Grid-Tie
Bug Proof / Filtered /Screened
GVFX3524 / GVFX3648

OutBack Power Systems GFX’s (Grid-tie FX) come in two styles. The GTFX (Grid-tie Turbo FX) is a sealed FX with an external fan to provide cooling and an extra power boost. The GVFX (Grid-tie Vented FX) is a vented FX that intakes air and directs it over the transformer. These GFX’s are capable of selling power back to your local utility while giving you the piece of mind of a back-up power system in case the utility fails.

The components necessary to a system involving a GFX are (in order of power flow) the sun, solar panels (or other renewable energy sources), solar charge controller(s) (OutBack’s MX-60 is recommended), battery bank of the proper voltage and capacity (minimum of 100 amp-hours recommended), the GFX(s), and the utility grid. The utility grid attaches to the GFX at its AC Input terminals.

The GFX comes pre-programmed to operate, even without the Mate. The Mate is necessary to program the GFX (stacking, auto generator start, etc.) and must be connected for functions that involved the clock (advanced generator start) or to view voltage and current meters and “Error” messages. The Mate is highly recommended for Grid-Tie systems.

GRID TIE / UTILITY INTERACTIVE CAPABLE
Able to sell solar, wind or hydro power back to the utility grid - Reduce your utility bill by spinning your meter backwards!

PROVIDES UTILITY BACK-UP POWER
Keeps your lights on when the power goes out as well as other loads like wells,TV, fridge, computer, garage door opener, alarm etc,.

WORKS AUTOMATICALLY
Built in transfer switch automatically disconnects the house loads from the utility grid and powers them from the inverter during an outage.

SAFE AND APPROVED
Listed to UL1741 standard as a non-islanding power inverter system for renewable energy applications. Also listed with IEEE 1547 and IEEE 1547.1 (**see Declaration of Conformity in Documents Section above).

ULTRA CLEAN AC POWER
Smooth, true sinewave AC output waveform - not a course stepped sinewave or modified square wave.

INTELLIGENT BATTERY CHARGER
Advanced charging algorithms provide fast recharging while increasing battery life up to 10 years.

FIELD SERVICEABLE
Both FX and VFX inverter/chargers can be upgraded or serviced - even in the field.

NETW NETWORKED COMMUNICATIONS
All of OutBack products can be connected through a HUB to form a network with monitoring and control via a single MATE display

CAPABLE TECH SUPPORT HELP
T You can call or email and ask questions of the engineers that designed your products - Tech support doesn’t get any better than that.

FEATURES:
ZERO watts of AC power draw at night - automatic “silent” sell mode built in. Daily energy production on par with battery-less gridtie inverter systems Modular configuration allows easy system expansion and flexible design with up to 10 inverters interconnected. Integrated communication between the inverters and the charge controllers ensure proper operation Automatically optimizes the conversion effeciancy by matching the number of inverters to the amount of power being sold or used.


SPECIFICATIONS GTFX2524 GTFX3048 GVFX3524 GVFX3648
Continuous Power @ 25°C 2500W 3000W 3500W 3600W
Nominal DC Input Voltage 24 48 24 48
Nominal AC Voltage & Frequency
120 VAC 60 Hz
Continuous Output @ 25°C 21 amps 25 amps 29amps 30 amps
Idle Power (with AC output / no load) 18-20W 21-23W 18-20W 21-23W
Efficiency (typical at 25oC & 75% load) 91% 92% 91% 92%
Total Harmonic Distortion (voltage)
2% typical / 5% maximum
Output Voltage Regulation
+/- 2% typical
Surge Power Capability - AC output

Peak (1mSec)

70 amps AC

RMS (100mSec)

50 amps AC

Overload Capability (from 25oC start)

5 second

4800W 4800W 4800W 5000W
30 minutes 3200W 3200W 3200W 4000W
Automatic AC Transfer Relay
60 amps AC
AC Input Current
60 amps AC max
AC Input Voltage Range
108-132 VAC (Grid-Tie Mode)
Frequency Range - AC input
59.3-60.5 Hz (Grid-Tie Mode)
DC Input Voltage Range 20-33V 40-66V 20-33V 40-66V
Recommended DC Breaker OBDC-175 OBDC-100 OBDC-250 OBDC-175
Continuous Battery Charger Output 55 35 85 45
Shipping Weight
66 Lbs / 30kg
62 Lbs / 28kg

 

Outback GridTied System

 

Outback Power Systems


Click here for BBB Business Review ASE NESEA Member
Paypal Visa MasterCard Amex Discover
McAfee SECURE sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams