Log in | My Account | ![]()
Cart: 0 items
| List Price: | $899.00 |
| Our Price: | $719.20 Save: $179.80 (20%) |
| Model: | MM1212 |
| Brand: | Magnum Inverters |
|
Our Code: MAGMM1212 |
Magnum EnergyThe MM Series
Inverter/Charger from Magnum
Energy – a new modified sine
wave inverter providing a cost
effective solution for those with
smaller power needs in mobile
applications. Versatile, easy-to-use,
and lightweight, the MM Series
provides a reliable base for your
energy system.

Accessories and
Options
Remote control: Optional remotes
are available for the MM Series,
including the MM-R, MM-RC,
and the ME-RC. A four wire
phone jack comes standard with the
unit to connect the remote.
Specifications
| MM612 | MM1212 | |
| Inverter Specifications | ||
| Input battery voltage range | 9 to 15.5 VDC | 9 to 15.5 VDC |
Nominal AC output voltage |
120 VAC ± 5% | 120 VAC ± 5% |
Output frequency and accuracy |
60 Hz ± 0.005% | 60 Hz ± 0.005% |
1 msec surge current (amps AC) |
27 | 42 |
100 msec surge current (amps AC) |
11 | 23 |
5 sec surge power (real watts) |
1100 | 2100 |
10 sec surge power (reall watts) |
1050 | 1900 |
30 sec surge power (real watts) |
1000 | 1750 |
5 min surge power (real watts) |
950 | 1450 |
30 min surge power (real watts) |
675 | 1375 |
Continuous power output at 25° C (with 1.0 PF) |
600 VA | 1200 VA |
| Continuous current output | 5 A AC | 10A AC |
| Rated input battery current | 60 ADC | 125 ADC |
| Inverter efficiency | 95% | 95% |
| Transfer time | 16 msecs | 16 msecs |
| No Load (120 VAC output) | .77 ADC | 1.3 ADC |
| Waveform | Modified Sine Wave | Modified Sine Wave |
| Charger Specifications | ||
Continuous output at 25° C |
NA | 70 ADC |
Charger efficiency |
NA | 88% |
Power factor |
NA | > 0.95 |
Input current at rated output (AC amps) |
NA | 9 |
General Features and Capabilities |
||
| Transfer relay capability | 7 A AC | 12A AC |
| Battery temperature compensation | Yes, on models with chargers: standard temp sensor (battery temp 0 – 50° C) |
|
| Remote available (optional) | Yes, MM-R or ME-RC |
|
| Internal cooling | 0 to 59 cfm variable speed |
|
| Overcurrent protection |
Yes, with two overlapping circuits |
|
| Overtemperature protection | Yes on transformer and MOSFETS |
|
| On/Off with status indicator | Yes, front mounted and easily accessible |
|
| Low battery cutout | 10 VDC, adjustable on most models with the ME-RC remote |
|
AC output and input |
Hardwire | Hardwire |
Output circuit breaker |
7 A switchable | 12 A switchable |
Input circuit breaker |
7 A AC | 16 A AC |
Listings |
ETL Listed to UL/cUL458, CSA C22.2 #107.1-01 |
|
| Warranty | Two years |
|
| Environmental Specifications | ||
| Operating temperature | -20° C to +60° C (-4° F to 140° F) |
|
| Nonoperating temperature | -40° C to +70° C (-40° F to 158° F) |
|
| Operating humidity | 0 to 95% RH non condensing |
|
| Physical Specifications | ||
| Dimensions (l x w x h) | 16.6” x 8.4” x 4.7” (42 cm x 21 cm x 12 cm) |
|
| Mounting | Shelf (top or bottom up) or bulkhead (vents up) | |
| Weight | 14 lb (6.4 kg) |
20 lb (9 kg) |
| Max operating altitude | 15,000ft (4570 m) |
|
| Construction | ABS plastic top and cast aluminum bottom |
|
Minimum Wire Size to Circuit Breaker Size |
||||
|
Inverter Model |
Input |
Output |
||
|
Minimum Wire Size |
Suggested Breaker Size |
Minimum Wire Size |
Suggested Breaker Size |
|
|
MM612 |
#14 AWG |
7 amps |
#14 AWG |
10 amps |
|
MM612AE |
#14 AWG |
8 amps |
#14 AWG |
10 amps |
|
MM1212 |
#12 AWG |
20 amps |
#14 AWG |
15 amps |
|
MM1212AE |
#12 AWG |
20 amps |
#14 AWG |
15 amps |
|
MM1012E |
#14 AWG (1-2mm) |
8 amps |
#14 AWG (1-2mm) |
7 amps |
|
MMS1012 / MMS1012-G |
#12 AWG |
20 amps |
#14 AWG |
12 amps |
|
MM1321E |
#14 AWG (1-2mm) |
8 amps |
#14 AWG (1-2mm) |
7 amps |
|
MM1524AE |
#12 AWG |
20 amps |
#14 AWG |
12 amps |
Recommended DC Wire Overcurrent Device |
||||||
| Inverter Model |
MM612 / MM612AE |
MMS1012 / MMS1012G |
MM1012E |
MM1212 / MM1212AE |
MM1324E |
MM1524AE |
| Full Load DC-Input Current |
60 amps |
102 amps |
111 amps |
125 amps |
65 amps |
70 amps |
Minimum Wire Size |
#4 AWG |
#1 AWG |
#1 AWG |
#1 AWG |
#4 AWG |
#4 AWG |
Maximum DC Input Current |
78 amps |
131 amps |
131 amps |
157 amps |
85 amps |
98 amps |
Maximum DC Overcurrent Device |
125 amps |
200 amps |
200 amps |
200 amps |
125 amps |
125 amps |
DC / chassis Ground Wire Size |
#6 AWG |
#6 AWG |
#6 AWG |
#6 AWG |
#6 AWG |
#6 AWG |