Log in | My Account | ![]()
Cart: 0 items
| List Price: | $529.00 |
| Our Price: | $423.20 Save: $105.80 (20%) |
| Model: | MM612 |
| Brand: | Magnum Inverters |
|
Our Code: MAGMM612 |
Magnum EnergyThe MM Series
Inverter/Charger from Magnum
Energy – a new modified sine
wave inverter providing a cost
effective solution for those with
smaller power needs in mobile
applications. Versatile, easy-to-use,
and lightweight, the MM Series
provides a reliable base for your
energy system.

Accessories and
Options
Remote control: Optional remotes
are available for the MM Series,
including the MM-R, MM-RC,
and the ME-RC. A four wire
phone jack comes standard with the
unit to connect the remote.
Specifications
| MM612 | MM1212 | |
| Inverter Specifications | ||
| Input battery voltage range | 9 to 15.5 VDC | 9 to 15.5 VDC |
Nominal AC output voltage |
120 VAC ± 5% | 120 VAC ± 5% |
Output frequency and accuracy |
60 Hz ± 0.005% | 60 Hz ± 0.005% |
1 msec surge current (amps AC) |
27 | 42 |
100 msec surge current (amps AC) |
11 | 23 |
5 sec surge power (real watts) |
1100 | 2100 |
10 sec surge power (reall watts) |
1050 | 1900 |
30 sec surge power (real watts) |
1000 | 1750 |
5 min surge power (real watts) |
950 | 1450 |
30 min surge power (real watts) |
675 | 1375 |
Continuous power output at 25° C (with 1.0 PF) |
600 VA | 1200 VA |
| Continuous current output | 5 A AC | 10A AC |
| Rated input battery current | 60 ADC | 125 ADC |
| Inverter efficiency | 95% | 95% |
| Transfer time | 16 msecs | 16 msecs |
| No Load (120 VAC output) | .77 ADC | 1.3 ADC |
| Waveform | Modified Sine Wave | Modified Sine Wave |
| Charger Specifications | ||
Continuous output at 25° C |
NA | 70 ADC |
Charger efficiency |
NA | 88% |
Power factor |
NA | > 0.95 |
Input current at rated output (AC amps) |
NA | 9 |
General Features and Capabilities |
||
| Transfer relay capability | 7 A AC | 12A AC |
| Battery temperature compensation | Yes, on models with chargers: standard temp sensor (battery temp 0 – 50° C) |
|
| Remote available (optional) | Yes, MM-R or ME-RC |
|
| Internal cooling | 0 to 59 cfm variable speed |
|
| Overcurrent protection |
Yes, with two overlapping circuits |
|
| Overtemperature protection | Yes on transformer and MOSFETS |
|
| On/Off with status indicator | Yes, front mounted and easily accessible |
|
| Low battery cutout | 10 VDC, adjustable on most models with the ME-RC remote |
|
AC output and input |
Hardwire | Hardwire |
Output circuit breaker |
7 A switchable | 12 A switchable |
Input circuit breaker |
7 A AC | 16 A AC |
Listings |
ETL Listed to UL/cUL458, CSA C22.2 #107.1-01 |
|
| Warranty | Two years |
|
| Environmental Specifications | ||
| Operating temperature | -20° C to +60° C (-4° F to 140° F) |
|
| Nonoperating temperature | -40° C to +70° C (-40° F to 158° F) |
|
| Operating humidity | 0 to 95% RH non condensing |
|
| Physical Specifications | ||
| Dimensions (l x w x h) | 16.6” x 8.4” x 4.7” (42 cm x 21 cm x 12 cm) |
|
| Mounting | Shelf (top or bottom up) or bulkhead (vents up) | |
| Weight | 14 lb (6.4 kg) |
20 lb (9 kg) |
| Max operating altitude | 15,000ft (4570 m) |
|
| Construction | ABS plastic top and cast aluminum bottom |
|
Minimum Wire Size to Circuit Breaker Size |
||||
|
Inverter Model |
Input |
Output |
||
|
Minimum Wire Size |
Suggested Breaker Size |
Minimum Wire Size |
Suggested Breaker Size |
|
|
MM612 |
#14 AWG |
7 amps |
#14 AWG |
10 amps |
|
MM612AE |
#14 AWG |
8 amps |
#14 AWG |
10 amps |
|
MM1212 |
#12 AWG |
20 amps |
#14 AWG |
15 amps |
|
MM1212AE |
#12 AWG |
20 amps |
#14 AWG |
15 amps |
|
MM1012E |
#14 AWG (1-2mm) |
8 amps |
#14 AWG (1-2mm) |
7 amps |
|
MMS1012 / MMS1012-G |
#12 AWG |
20 amps |
#14 AWG |
12 amps |
|
MM1321E |
#14 AWG (1-2mm) |
8 amps |
#14 AWG (1-2mm) |
7 amps |
|
MM1524AE |
#12 AWG |
20 amps |
#14 AWG |
12 amps |
Recommended DC Wire Overcurrent Device |
||||||
| Inverter Model |
MM612 / MM612AE |
MMS1012 / MMS1012G |
MM1012E |
MM1212 / MM1212AE |
MM1324E |
MM1524AE |
| Full Load DC-Input Current |
60 amps |
102 amps |
111 amps |
125 amps |
65 amps |
70 amps |
Minimum Wire Size |
#4 AWG |
#1 AWG |
#1 AWG |
#1 AWG |
#4 AWG |
#4 AWG |
Maximum DC Input Current |
78 amps |
131 amps |
131 amps |
157 amps |
85 amps |
98 amps |
Maximum DC Overcurrent Device |
125 amps |
200 amps |
200 amps |
200 amps |
125 amps |
125 amps |
DC / chassis Ground Wire Size |
#6 AWG |
#6 AWG |
#6 AWG |
#6 AWG |
#6 AWG |
#6 AWG |
Congratulations to Rob C on being our Feb 2010 Renewable Rewards Monthly Drawing winner!
AltE launches the community driven Kill A Watt Database!
AltE is making renewable energy educational videos free to the public!
AltE® University has been awarded Institute for Sustainable Power (ISP) Training Program accreditation, by the Interstate Renewable Energy Council (IREC) for its Photovoltaic Design and Installation and Solar Thermal Design and Installation courses offered in the Hudson, MA headquarters.
Hudson, Massachusetts based The Alternative Energy Store is reinventing itself. Launching a re-branding campaign on August 5, 2008, the Alternative Energy Store, found on the web at http://www.altEstore.com will now be AltE... (more)
Alternative Energy Store was named one of America's fastest growing companies by Inc. magazine...
Check out one of the Alt-E founders on CNNfn. ( rm | mov | wmv )
more »