| List Price: | $3,950.00 |
| Our Price: | $2,850.00 Save: $1,100.00 (28%) |
| Model: | 865-1005 |
| Brand: | Xantrex |
|
Our Code: XANXW4548 |
Xantrex
XW Hybrid Inverter/Chargers
XW4024, XW4548, XW6048
Features
Optional Accessories:
|

Specifications
| Electrical Specifications | XW6048-120/240-60 | XW4548-120/240-60 | XW4024-120/240-60 |
| Continuous output power |
6,000 W | 4500 W | 4000 W |
| Surge rating (10 seconds) | 12,000 W | 9000 W | 8000 W |
| Surge current | L-N: 105 Arms (7 sec) L-L: 40 Arms (20 sec) |
L-L: 52.5 Arms (7 sec) L-N: 70 Arms (20 sec) |
L-N: 75 Arms (20 sec) L-L: 35 Arms (20 sec)> |
| Waveform | True sine wave | True sine wave | True sine wave |
| Low-load efficiency
|
95% | 95% | 95% |
| Idle consumption - search mode | < 8 W | < 8 W | < 8 W |
| AC connections | AC1 (Grid), AC2 (Generator) | AC1 (Grid), AC2 (Generator) | AC1 (Grid), AC2 (Generator) |
| AC voltage | 120/240 Vac split-phase | 120/240 Vac split-phase | 120/240 Vac split-phase |
| AC input breaker | 60 A two-pole | 60 A two-pole | 60 A two-pole |
| Utility interactive | Yes | Yes | Yes |
| CEC weighted efficiency | 92.5% | 93% | 91% |
| CEC power rating | 5752 W | 4500 W | 4000 W |
| AC input voltage range (bypass/charge mode) | L-N: 80 - 150 Vac (120 V nominal); L-L: 160 - 270 Vac (240 V nominal) | ||
| AC input frequency range (bypass/charge mode) | 55 - 65 Hz (default); 44 - 70 Hz (allowable) | ||
AC1 voltage range – Sell mode |
L-N: 108 - 130 +/- 1.5 Vac; L-L: 214 - 260 +/- 3.0 Vac | ||
| AC1 frequency range – Sell mode (automatically adjusts when entering Sell mode)* |
59.4 - 60.4 +/- 0.05 Hz | ||
| AC output voltage | L-N: 120 Vac +/- 3%; L-L: 240 Vac +/- 3% | ||
| AC output frequency | 60.0 +/-0.1 Hz | ||
| DC current at rated power | 130 A | 96 A | 178 A |
| Total harmonic distortion | < 5% | ||
| Automatic transfer relay | 60 A | ||
| Typical transfer time | 8 ms | ||
| DC input voltage (nominal) | 50.4 Vdc | 50.4 Vdc | 25.2 Vdc |
| DC input voltage range | 44 - 64 Vdc | 44 - 64 Vdc | 22 - 32 Vdc |
| Maximum continuous charge rate | 100 A | 85 A | 150 A |
| Efficiency at maximum charge rate | 89.4% | 90.2% | 85.8% |
| Power factor corrected charging | 0.98 | 0.98 | 0.98 |
| Emissions | FCC Class B | FCC Class B | FCC Class B |
| Multiple-unit configurations | Up to three parallel units in 120/240-volt split-phase configuration | ||
| Auxiliary relay output | 0-12 Vdc, maximum 250 mA DC | ||
| Non-volatile memory | Yes | Yes | Yes |
| System network | Xanbus™ (publish-subscribe network, no need for hubs or special cards) | ||
| Mechanical Specifications |
|||
| Mounting | Wall mount, backplate included | ||
| Inverter dimensions (H x W x D) | 23 x 16 x 9” (580 x 410 x 230 mm) | ||
| Inverter weight | 125 lb (57 kg) | 115 lb (52 kg) | 115 lb (52 kg) |
| Shipping dimensions | 28 x 22 ¼ x 10 ½” (711 x 565 x 267 mm) | ||
| Shipping weight | 132 lb (60 kg) | 122 lb (55 kg) | 122 lb (55 kg) |
| Display panel | Status LEDs indicate AC In status, faults/warnings, equalize mode, battery level. Three-character display indicates output power or charge current, fault/warning codes. On/Off and equalize buttons | ||
| Battery temperature sensor | Included | Included | Included |
| Standard warranty | Five years | Five years | Five years |
| Part number | 865-1000 | 865-1005 | 865-1010 |
| Environmental Specifications | |||
| Enclosure type | NEMA Type 1 – Indoor (sensitive electronic components sealed inside enclosure) | ||
| Operational temperature range | -13 to 158 °F (-25 to 70 °C) | ||
| Accessories | |||
| Remote display | Optional XW System Control Panel monitors and configures all devices connected to Xanbus™ Network | ||
| Generator support | Optional XW Automatic Generator Start module connects to Xanbus™ Network. Automatically activates generator to recharge depleted battery bank or assist inverter with heavy loads | ||
| Power distribution & panel conduit boxes | Optional balance-of-systems components for NEC compliant installations, includes pre-wired AC and DC circuit breakers, bus bars and multiple knockouts for conduit and additional breakers | ||
| Regulatory Approvals | UL 1741 1st Edition: 2005 Version CSA 107.1-01 | ||

“I am new to actually using and setting up Alt Energy, and you guys made it accessible, affordable and offered suggestions and guidance every step of the way. To put into perspective how important this is here is a little story. I work in magazine publishing and have been using Adobe Photoshop for more than 15 years and have bought several copies of every version from v1 upto the current v8. I am quite knowledgeable in computers and programs, but was having a problem. I called Adobe, explained my situation, and told them I only had one question. The were quite rude and would not go any further unless I gave the $39.99 per incident.