Square D D221NRB 30 Amp 240 VAC 2 Pole Disconnect

Square D D221NRB 30 Amp 240 VAC 2 Pole Disconnect
List Price: $91.30
Our Price: $80.50     Save: $10.80 (12%)
Model: D221NRB
Brand: Square D
Availability: In Stock
Quantity

Estimate Shipping.

Need help selecting components and designing your system?
Give our Knowledgeable Sales Folks a call at 877-878-4060.

Basic Stats click to view hide

Amps: 30 A
Our Code: SQUD221NRB

Reviews click to view hide

There are currently no reviews. If you own this product write a review!

Add-Ons & Accessories click to view hide

These items are commonly used with the Square D D221NRB 30 Amp 240 VAC 2 Pole Disconnect

Details click to view hide


Don't forget to order the Ground Kit for this item!

Square D LogoSquare D
Nema 3R Disconnect
s

Square D disconnectAccording to the National Electric Code, section 690.15, PV arrays must have a disconnecting means to isolate the inverter from the PV power source. Utility intertie inverters that utilize PV arrays with voltages above 250 VDC require a disconnect rated for 600 VDC to perform this function. The Square-D 600 VDC 30 amp 3-pole safety switches are UL listed to handle 13A at 600VDC per pole. They can be used for disconnecting up to three PV arrays for three grid-tie inverters. It has wiring lugs that are rated to accept two #14 to #10 wires in each lug. This allows the disconnect switch to also act as a string combiner in systems that utilize two strings of PV modules per inverter. All other Square D 600 VDC disconnects are rated for disconecting one string at full rated power.

Many utilities require an AC disconnect between an intertie inverter and the AC load center, close to the AC service entrance, with a visible and lockable handle. A 30 amp 240 volt disconnect is good for up to 5kW at 240 VAC (one or two 2500W intertie inverters) and the 60 amp disconnect is good for up to 12.5kW (three to five 2500W intertie inverters). For connection of multiple inverters to one of these disconnects, use an AC load center, with a circuit breaker for each inverter installed, as an AC combiner box between the inverters and the disconnect switch.The breakers can be back-fed with the inverter outputs and the load center main lugs will handle the combined outputs to be connected to the AC disconnect.

Use Class-R fuses of the proper amperage for fused disconnects. Disconnects are raintight (NEMA 3R) for outdoor use.

Model Maximum Voltage System Voltage Poles Ampere Rating Enclosure Dimensions Weight Fusible
H361RB 600 VAC/ VDC 600 VDC 3 30 Amp Nema 3R 14.88" x 6.63" x 4.88" 9.8 lbs Yes
DU221RB 240 VAC 240 VAC 2 30 Amp Nema 3R 9.63" x 7..25" x 3.75" 4.4 lbs. No
D221NRB 240 VAC 240 VAC 2 30 Amp Nema 3R 9.63" x 7..25" x 3.75" 4.5 lbs. Yes

 

 

 


Send to a friend Write a review Request more info
HACKER SAFE certified sites prevent over 99.9% of hacker crime. BizRate Customer Certified (GOLD) Site
Open Today 8:30 AM - 8 PM EST! Call Us!
877-878-4060

Se habla Español
LiveZilla Live Help
 

browse by brand

 
 
Why buy from us? Sign up for our Newsletters Save / Earn Money Have a suggestion? Found a bug?

Customer testimonials

“I'm really happy for the support you gave (and I had just given one of [your competitor's] many answer machines a hard time, so you can tell your bosses that friendly phone service works! :-) )
cheers”

Eva - Stuart, FL

“Eric is a great guy and a great asset to your organization. Very attentive and knowledgeable about the products he represents.”

Henry - Houston, TX

“I trusted you somehow and I never buy from the internet so that is saying a lot!”

Carla - Carlsbad, CA

more testimonials ...