Sizing PWM Charge Controllers

How to size a shunt or PWM type charge controller. With a little math, it's pretty easy. However, please pay attention to the explanations about the math!

written by Ben Gorman

Charge Controller Sizing, Part 1: PWM & Shunt

All renewable energy (RE) systems with batteries should include a charge controller. Charge controllers prevent battery overcharging and also prevent the batteries from sending their charge back through the system to the charging source (i.e., the solar panels). Think of a charge controller as a battery nurse—its job is to monitor the battery bank, feeding it what it needs and checking its vital signs. Since a charge controller does its work in line between the solar array and the batteries, it would make sense that its selection and sizing would be influenced by those components. And that’s exactly the case.

Voltage and amperage (or current) are the parameters we use in charge controller sizing. The charge controller must be capable of accepting the voltage and current produced by the DC source and delivering the proper voltage and current to the batteries. This situation might make you think that the DC source, charge controller and batteries must all share a common voltage. While that is one system design strategy used in many installations, it’s not the only one. More on the alternatives later. For now, it’s one voltage for everyone!

Technically speaking, the DC source must always have a higher operating voltage than the battery bank in order for current to flow from one to the other. A handy way to remember this fact is the statement, “Voltage flows downhill.” For the purpose of this discussion, we’ll use which means common battery voltages. Nominal voltage in this sense is synonymous with . Since batteries (where they are used) are in many ways the heart of an RE system, we can call the bank’s voltage the system voltage. The system voltage selected for any given installation is usually, though not always, determined by the battery bank required by the application; the inverter, if one is used, will also influence the choice of system voltage. 

 

Sizing comes down to this: there’s the quick method, which will very likely give an acceptable, if perhaps oversized result, but won’t describe the why ; and there’s the more detailed method, which will reveal all the steps for greater understanding and precision. We’ll look at both methods.

Short Method:

 

Sizing Charge Controllers
(Short Method)

Example&
(Short Method)

  1. For PWM and PWM shunt controllers, select one that is rated at your system voltage (same nominal voltage all the way through the system).
  2. Divide array total wattage by system voltage.
  3. Add 20% as a safety margin (i.e., (result of Step 2) X 1.2).
  4. Select a controller rated at or above the result of Step 3.
  1. Two 125W, 12V nominal modules. System is 250 W, 12 Volt nominal. Charge controller will be 12 Volts.
  2. 250 ÷ 12 = 20.83
  3. 20.83 * 1.2 = 24.996 amps
  4. You could use a Go Power 25 amp; Xantrex C35; or a Morningstar Prostar 30, for example. (Any 12 volt controller greater than 25 amps)

 

 

The Detailed Method (with mysteries revealed!):

 

In systems using the one-voltage-in-and-out charge controller type, all three main components must match nominal voltage throughout the system: the photovoltaic (PV) array, the charge controller, and the battery bank. Such charge controllers come in either of two types: shunt or PWM (Pulse Width Modulated). So for these situations, the first step in charge controller selection or sizing is voltage selection:

Match your voltages!
Make sure all of your voltages are equal!

 

1. A shunt or PWM charge controller must match the system voltage.

The next step in sizing involves current . You might think we could simply match a given PV module (or array) output current, as it appears on the module’s label, with a charge controller that is rated to accept at least that current; and we could do that, but there’s a risk involved. PV modules’ current output varies with changing conditions of temperature and sunlight intensity, so we must add a prudent safety margin to ensure that the charge controller is not subjected to potentially damaging amperage. Zap! = bad. Adjusting the controller’s rating values is called “de-rating”. This step is a matter of a simple calculation based on the solar array’s rated output current.

That rating is easily obtained for a single-module system: just look at the label on the back of the module. Current output is listed there in at least two ratings: Imp , or current at maximum power, and Isc , or short-circuit current. Isc is always higher than Imp and sizing calculations are always based on Isc even though a short circuit in the system may seem like an unlikely occurrence. The important point here is that there are conditions under which a module can produce more than its rated current. We must protect the charge controller against those circumstances; hence the de-rating.

We use a standard factor to account for all PV output-boosting circumstances (read more about the specific conditions in Charge Controller Sizing, Park 2) [link to that article]. That factor is 1.25 or 125%. So our formula for current safety margin (de-rating) might look like this:

 

2. Module Isc X 1.25 = minimum charge controller amperage (A) rating.

 

This value is the minimum needed charge controller amperage rating. Of course, there may be no charge controller available that offers that exact amperage rating value. Common ratings include 5A, 6A, 8A, 10A, 12A, 15A, 20A, 25A, and on up to 70A. Select a charge controller with a rating equal to or higher than your de-rated value. Always “round” upward.

If the array consists of more than one module, we must be sure to take the array wiring scheme into account as we calculate voltage and amperage, since the wiring method affects these figures. wiring produces additive voltage and constant amperage; wiring produces additive amperage and constant voltage. Calculate total array current accordingly. Our Step 2, then, would properly read:

 

2. Array Isc X 1.25 = minimum charge controller current (A) rating.

A second de-rating factor may be required. For systems in continuous operation, additional protection must be included, according the National Electric Code (NEC), to allow for heat and equipment stress. Continuous operation is defined as three hours or longer of continuous use, which would include most PV systems. This factor is also 1.25 or 125%. We can either run this second calculation after the first, like so:

3. (Result from 2. above) X 1.25 = fully de-rated min. charge controller (A) rating.

 

Or we can combine the two calculations into one, using the following close approximation:

2. (Alternate calculation) Array Isc X 1.56 = fully de-rated min. charge controller (A) rating.

 

Why use two different multipliers?

The reason we point out these two ratings separately is that many charge controller manufacturers already include this 2nd de-rating (for continuous use) in their products’ rating figures. Case in point is the Morningstar brand. Their charge controllers are essentially already rated for continuous use. With a Morningstar controller, a total de-rating factor of 1.25 is all that’s needed for a given system. If you’re unsure whether the controller you’re considering has already been de-rated for continuous use, err on the side of caution and use the 1.56 factor in your calculations. Turn the page for a summary of the method.

 

So our detailed method steps go like this:

Sizing Charge Controllers
(Short Method)

Example
(Short Method)

  1. A shunt or PWM charge controller must match the system voltage.
  2. Array Isc X 1.25 = (A) de-rating for 1st safety margin.
  3. If needed, include continuous-use de-rating: (Result from Step 2) X 1.25 = fully de-rated min. charge controller (A) rating.
  4. Select controller rated as equal to or greater than result in Step 3.
Two 125W, 12V nominal modules, wired in parallel (12V system voltage); module Isc = 8.0A:
  1. 12V nominal voltage requires 12V nominal charge controller.
  2. 8.0A X 2 = 16A
  3. 16A X 1.25 = 20A
  4. 20A X 1.25 = 25
  5. Some charge controller options: GoPower! 25A or Morningstar SunSaver 20A*. (You could still use the C35 or Morningstar Prostar 30 as well)

* The 20 amp Morningstar is an option because it is already "derated" and accounts for the additional 25% increase.

 

Notice that the second (more detailed) calculation has led to a lower amperage value and therefore different charge controller options. You can see that, in this case at least, the short method has resulted in a bigger margin of safety than the detailed method. Is this a problem? Not really—all the controllers mentioned will be perfectly fine in this system. So unless you’re on a very tight budget and the difference between one charge controller price and the next one up will break you bank, use the method you’re most comfortable with.

 

Alternatives

 

In some cases, it makes sense to have a PV system with a higher-voltage array to reduce voltage drop over long distances; yet you may need a lower-voltage battery bank to run some appliances (e.g., a 48V array and a 12V battery bank).  In those instances you can utilize the special powers of a different class of charge controllers. They represent the alternative strategy I hinted at earlier: it’s a charge controller technology that can make them “smart” enough to handle DC sources with substantially higher voltages than the batteries they’re feeding. The smart ones are called MPPT (Maximum Power Point Tracking) charge controllers. You can read about them in Part 2 of this article.

 

Plan Ahead!

 

What you don’t plan for can come back and bite you in the behind! Ambient conditions of sunlight intensity and temperature can boost your PV array voltage and current output and put your charge controller at risk. Save yourself money and hassle by planning your RE system carefully, making appropriate allowances for conditions—however unlikely—that can affect component sizing calculations. Over time, the money you save can go toward expansion of your RE system.